Estimation of internal-exposure contribution in radiation dose exposure for boron neutron capture therapy

被引:0
|
作者
Narita, Ryosuke [1 ]
Sakurai, Yoshinori [2 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Nishikyo Ku, Kyoto 6158530, Japan
[2] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, 2 Asashiro Nishi, Kumatori, Osaka 5900494, Japan
关键词
D O I
10.1093/rpd/ncae073
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Although boron neutron capture therapy (BNCT) causes minor damage to normal cells owing to the nuclear reactions induced by neutrons with major elements of tissues such as hydrogen and nitrogen, it is useful to estimate the accurate exposure dose for radiation protection. This study aims to estimate the contribution of internal exposure in radiation exposure dose for BNCT. The study was performed by referring to clinical studies at a reactor-based BNCT facility on the basis of computational dosimetry. Five irradiation regions of head and neck were selected for the estimation. The results suggest that external exposure occurred primarily in and around the irradiation field. Furthermore, during the exposure dose estimation in BNCT, internal exposure was found to be not negligible, implying that the irradiation regions in treatment planning must be considered for avoiding damage to certain critical organs that are susceptible to internal exposure.
引用
收藏
页码:623 / 628
页数:6
相关论文
共 50 条
  • [21] 3-DIMENSIONAL RADIATION-DOSE DISTRIBUTION ANALYSIS FOR BORON NEUTRON-CAPTURE THERAPY
    WHEELER, FJ
    NIGG, DW
    NUCLEAR SCIENCE AND ENGINEERING, 1992, 110 (01) : 16 - 31
  • [22] METHODS FOR RADIATION-DOSE DISTRIBUTION ANALYSIS AND TREATMENT PLANNING IN BORON NEUTRON-CAPTURE THERAPY
    NIGG, DW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1121 - 1134
  • [23] A comparison of dose distributions in gross tumor volume between boron neutron capture therapy alone and combined boron neutron capture therapy plus intensity modulation radiation therapy for head and neck cancer
    Lee, Jia-Cheng
    Chuang, Keh-Shih
    Liu, Yen-Wan Hsueh
    Lin, Tzung-Yi
    Teng, Yi-Chiao
    Wang, Ling-Wei
    PLOS ONE, 2019, 14 (04):
  • [24] RADIATION-DOSE HETEROGENEITY IN RECEPTOR AND ANTIGEN-MEDIATED BORON NEUTRON-CAPTURE THERAPY
    HARTMAN, T
    CARLSSON, J
    RADIOTHERAPY AND ONCOLOGY, 1994, 31 (01) : 61 - 75
  • [25] The dependence of the microscopic dose in boron neutron capture therapy on cell geometry and boron content
    Nichols, T
    Miller, L
    Kabalka, G
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 609 - 612
  • [26] ESTIMATION OF INTERNAL EXPOSURE TO RADIATION USING EMPIRICAL BAYES
    BARRY, SF
    STATISTICIAN, 1985, 34 (02): : 237 - 242
  • [27] Calculation of dose components in head phantom for boron neutron capture therapy
    da Silva, AX
    Crispim, VR
    CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (07) : 813 - 817
  • [28] Initial trials of a dose monitoring detector for boron neutron capture therapy
    Bykov, T. A.
    Kasatov, D. A.
    Koshkarev, A. M.
    Makarov, A. N.
    Porosev, V. V.
    Savinov, G. A.
    Shchudlo, I. M.
    Taskaev, S. Yu
    Verkhovod, G. D.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (01)
  • [29] Dose distribution in boron neutron capture therapy for the treatment of brain cancer
    Pereira, Leandro O.
    Freitas, Renato P.
    Ferreira, Douglas S.
    Felix, Valter S.
    Goncalves, Elicardo A. S.
    Pimenta, Andre R.
    Dutra, Rafael de Sousa
    da Silva, Ademir Xavier
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168 (168)
  • [30] DOSE HOMOGENEITY IN BORON NEUTRON-CAPTURE THERAPY USING AN EPITHERMAL NEUTRON BEAM
    KONIJNENBERG, MW
    DEWIT, LGH
    MIJNHEER, BJ
    RAAIJMAKERS, CPJ
    WATKINS, PRD
    RADIATION RESEARCH, 1995, 142 (03) : 327 - 339