Next steps in high-repetition-rate laser development for Thomson scattering

被引:0
|
作者
Den Hartog, D. J. [1 ]
Holly, D. J. [1 ]
Thomas, M. A. [1 ]
机构
[1] Univ Wisconsin Madison, Dept Phys, 1150 Univ Ave, Madison, WI 53706 USA
关键词
Lasers; Plasma diagnostics-interferometry; spectroscopy and imaging; Pulsed power;
D O I
10.1088/1748-0221/18/10/C10023
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Design of a next generation high-rep-rate laser system is underway, aiming for a maximum rep rate of 100 kHz for 1 ms. This will be a "pulse-burst" laser, which is a type of heat-capacity laser. Heat-capacity laser operation is characterized by a burst of pulses of limited duration, with burst length <= 100 ms and pulse rep rate >= 1 kHz. Waste heat accumulates in the laser rod during the burst. This heat is deposited evenly throughout the rod volume, with very little heat removed during the burst, such that temperature rises evenly across the rod radius. Thus beam distortion due to thermal gradients is small. Heat is removed from the rod after the burst, with typically tens of seconds between bursts. Pulse-burst operation of flashlamp pumped Nd:YAG lasers is a cost-effective route to high-rep-rate capability. Pulse-burst laser systems with "fast burst" rep rates in the range of 10-20 kHz have been built for the Thomson scattering diagnostics on MST, NSTX-U, and LHD. For Thomson scattering diagnostic application, the typical requirements are 1064 nm, 1-2 J/pulse, <= 30 ns FWHM pulse, with a top-hat beam profile. A major requirement for this next generation laser system is flexibility in burst sequence programs, ranging from 1 kHz for 100 ms to 100 kHz for 1 ms, and a variety of scenarios in between so that operation can be tailored to plasma experiment requirements. Flashlamp pumping will be used for this next generation laser because it is inexpensive and flexible. A new switch-regulated flashlamp driver will provide improved flashlamp control at lower cost. Additional design issues such as the optimum flashlamp pumping spectrum and optimum Nd doping will be addressed. The use of commercial off-the-shelf components will be maximized in this laser system so that pulse-burst systems can be developed and built by others for new applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Machine learning analysis of high-repetition-rate two-dimensional Thomson scattering spectra from laser-produced plasmas
    Eisenbach, S.
    Mariscal, D. A.
    Dorst, R. S.
    Van Hoomissen, T.
    Ortiz, A. M.
    Zhang, H.
    Pilgram, J. J.
    Constantin, C. G.
    Rovige, L.
    Heuer, P., V
    Schaeffer, D. B.
    Niemann, C.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2025, 58 (03)
  • [12] HIGH-REPETITION-RATE XENON LASER WITH TRANSVERSE EXCITATION
    TARG, R
    SASNETT, MW
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1972, QE 8 (02) : 166 - &
  • [13] Flexible high-repetition-rate ultrafast fiber laser
    Mao, Dong
    Liu, Xueming
    Sun, Zhipei
    Lu, Hua
    Han, Dongdong
    Wang, Guoxi
    Wang, Fengqiu
    SCIENTIFIC REPORTS, 2013, 3
  • [14] Flexible high-repetition-rate ultrafast fiber laser
    Dong Mao
    Xueming Liu
    Zhipei Sun
    Hua Lu
    Dongdong Han
    Guoxi Wang
    Fengqiu Wang
    Scientific Reports, 3
  • [15] HIGH-REPETITION-RATE XEF LASER WITH GAS RECYCLING
    CHRISTENSEN, CP
    APPLIED PHYSICS LETTERS, 1977, 30 (09) : 483 - 484
  • [16] HIGH-REPETITION-RATE CF4 LASER
    TELLE, J
    OPTICS LETTERS, 1982, 7 (05) : 201 - 203
  • [17] HIGH-REPETITION-RATE TRANSVERSE-FLOW XEF LASER
    WANG, CP
    APPLIED PHYSICS LETTERS, 1978, 32 (06) : 360 - 362
  • [18] DEVELOPMENT OF A HIGH-REPETITION-RATE MINI-TEA CO2-LASER
    MENYUK, N
    MOULTON, PF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1980, 51 (02): : 216 - 220
  • [19] Development of high-repetition-rate LD pumped Nd:YAG laser and its application
    Kiriyama, H.
    Yamakawa, K.
    LASER PHYSICS, 2006, 16 (04) : 666 - 672
  • [20] HIGH-REPETITION-RATE CONTINUOUSLY PUMPED RUBY-LASER
    TSENG, DY
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1972, QE-8 (07) : 675 - &