A new Multi Leaf Collimator for the fission neutron therapy facility at FRM II

被引:2
|
作者
Sommer, Lucas B. [1 ,2 ,3 ,4 ]
Chemnitz, Tobias [4 ]
Kampfer, Severin [1 ,2 ,3 ]
Bausenwein, Dominik [4 ]
Beimler, Alexander [4 ]
Kellermeier, Markus [4 ]
Schuetz, Rudolf [4 ]
Wilkens, Jan J. [1 ,2 ,3 ]
Wagner, Franz M. [4 ]
机构
[1] Tech Univ Munich, TUM Sch Med, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Dept Radiat Oncol, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[3] Tech Univ Munich, TUM Sch Nat Sci, Phys Dept, James Franck Str 1, D-85748 Garching, Germany
[4] Tech Univ Munich, Heinz Maier Leibnitz Zent MLZ, Lichtenbergstr 1, D-85748 Garching, Germany
关键词
Fast fission neutron therapy; Fast neutron therapy; Neutron dosimetry; Mixed field dosimetry; Two chamber method; Research reactor; MEDAPP; BEAM; KU;
D O I
10.1016/j.nima.2023.168717
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As a part of the general upgrade program of the fission neutron therapy facility MEDAPP at the research reactor FRM II, a newly designed, electronically operated Multi Leaf Collimator (MLC) was introduced. The design of the new collimator was optimized in order to increase dose output and to allow patient positioning closer to the collimator. The new collimator allows divergent and convergent beam shaping in order to maximize the effective area of the fission source used for irradiation. In comparison to the old MLC, the radiation dose for the staff is reduced by the motorized operation of the new MLC. The advanced beam shaping abilities of the new collimator are investigated by a comparison with depth dose curves and beam profiles of the old MLC.For the separation of neutron and gamma dose deposition in water, the two chamber dosimetry method recommended for mixed field dosimetry was applied. A re-calibration of the set of ionization chambers used for dosimetry in mixed neutron-gamma radiation fields at FRM II was performed. The calibration was done in a reference neutron field from 3H(p, n)3He-reactions in a low scattering environment.An overall increased dose output as intended by the design of the new MLC was shown. Also, improved dosimetric characteristics of the treatment field due to the optimized beam shaping abilities of the new MLC were demonstrated. In the calibration measurements of the magnesium ionization chamber used in the two chamber method, an unexpected increase of the neutron sensitivity by a factor of 8 was measured.The new MLC will enable more conformal dose delivery to the target volume in patients and therefore help to reduce healthy tissue damage by the application of neutron radiation.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Investigations of line scanning proton therapy with dynamic multi-leaf collimator
    Kim, Dae-Hyun
    Park, Seyjoon
    Jo, Kwanghyun
    Cho, Sungkoo
    Shin, Eunhyuk
    Lim, Do Hoon
    Pyo, Hongryull
    Han, Youngyih
    Suh, Tae-Suk
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 55 : 47 - 55
  • [42] Neutron flux parameters at irradiation positions in the new research reactor FRM-II
    Lin, Xilei
    Henkelmann, Richard
    Tuerler, Andreas
    Gerstenberg, Heiko
    De Corte, Frans
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (02): : 641 - 644
  • [43] DOSE MEASUREMENTS IN A P(50)+BE NEUTRON BEAM USING A CONTINUOUSLY VARIABLE MULTI LEAF COLLIMATOR
    MONTELIUS, A
    BRAHME, A
    EENMAA, J
    LINDBACK, S
    WOOTTON, P
    STRAHLENTHERAPIE, 1984, 160 (02) : 114 - 115
  • [44] Radiation field characterization with emphasis on the collimator configuration at the compact neutron source RANS-II facility
    Sugihara, Kenta
    Ikeda, Yujiro
    Kobayashi, Tomohiro
    Fujita, Kunihiro
    Ikeda, Shota
    Shigyo, Nobuhiro
    Otake, Yoshie
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2023, 60 (02) : 110 - 123
  • [45] The new PGAA facility at the FRM II, Garching:: comparison with the PIXE results obtained at the new IBA setup at Cologne
    Kudejová, P
    Materna, T
    Jolie, J
    Pascovici, G
    X-RAY SPECTROMETRY, 2005, 34 (04) : 350 - 354
  • [46] A new facility for high-energy neutron-induced fission studies
    Prokofiev, A
    Pomp, S
    Tippawan, U
    Bergenwall, B
    Blomgren, J
    Carlsson, M
    Dangtip, S
    Einarsson, L
    Haag, N
    Hildebrand, A
    Johansson, C
    Mermod, P
    Österlund, M
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2005, 769 : 800 - 803
  • [47] The new polarised hot neutron single crystal diffractometer POLI-HEiDi at FRM II
    Hutanu, Vladimir M.
    Meven, Martin
    Heger, Gernot
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C189 - C189
  • [48] The role of multi-leaf collimator (MLC) in replacing a cerrobend block in radiation therapy
    Cheng, C
    Das, IJ
    Steinberg, T
    RADIOLOGY, 1998, 209P : 398 - 398
  • [49] COMPUTER-ASSISTED GENERATION OF MULTI-LEAF COLLIMATOR SETTINGS FOR CONFORMATION THERAPY
    HOUNSELL, AR
    SHARROCK, PJ
    MOORE, CJ
    SHAW, AJ
    WILKINSON, JM
    WILLIAMS, PC
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (772): : 321 - 326
  • [50] Characterisation and optimisation of the new Prompt Gamma-ray Activation Analysis (PGAA) facility at FRM II
    Canella, Lea
    Kudejova, Petra
    Schulze, Ralf
    Tuerler, Andreas
    Jolie, Jan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 636 (01): : 108 - 113