Modeling and Control of Dielectric Elastomer Enabled Cuff Device for Enhancing Blood Flow at Lower Limbs

被引:1
|
作者
Kaaya, Theophilus [1 ]
Venkatraman, Rahul J. [1 ]
Koc, Denizcan [1 ]
Chen, Zheng [1 ]
机构
[1] Univ Houston, Dept Mech Engn, Houston, TX 77004 USA
基金
美国国家科学基金会;
关键词
Dielectric elastomer actuators; wearable devices; modeling; iterative learning control; ITERATIVE LEARNING CONTROL; PRESSURE; COMPRESSION;
D O I
10.1109/TASE.2023.3325617
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Orthostatic hypotension, deep vein thrombosis (DVT), and edema are venous system disorders that affect the lower limbs and are common causes of decreased work performance and affect the lives of many individuals. Compression devices, rotation of staff, and regular breaks can alleviate these problems. Active compression devices use air compression and require a pump, making them bulky. A calf muscle device that uses a dielectric elastomer as a soft actuator that is compact, lightweight, and resilient, making it convenient for use is developed. In this study, a physics-based model of the device is presented by combining the physics of a thin-walled dielectric elastomer vessel with the force interactions between the active vessel and the cylindrical passive elastomer within. The couplings between the two nonlinear elastic models are solved and a control-oriented model that is capable of capturing the pressure change experienced by the device under an applied voltage is established. A prototype of the device is made and characterized. The model is validated in the normal frequency range of the device. Human pulse signal tracking is then performed using adaptive iterative learning control (ILC) in a feedback loop. Experimental results have shown that the device can generate up to 10 Pa fluid pressure difference while tracking a human pulse signal with almost zero phase delay. Note to Practitioners-This paper describes a method that enhances blood flow using a comfortable soft cuff device. The device is made of dielectric elastomer which can generate contractions when it wraps around a lower limb to help circulate blood flow. Development of the cuff device could provide a preventive and proactive tool, as well as a rehabilitation tool, for regulating and improving blood flow. For example, this device could help a passenger who takes a long time flight to circulate his/her blood flow. This device could also help an athlete improve his/her muscle performance in highly intensive competitions. This paper details design, modeling, fabrication, and control of the device. A prototype of the device was fabricated and was able to generate enough contractions on an artificial lower limb to influence the blood pressure while tracking a human pulse signal. Experimental results have shown a great promise in enhancing blood flow with such a wearable and comfortable device.
引用
收藏
页码:6473 / 6482
页数:10
相关论文
共 50 条
  • [31] Modeling and adaptive pseudo-inverse control for dielectric elastomer actuated motion control systems
    Zhang, Xiuyu
    Guo, Fu
    Xu, Hongzhi
    Li, Zhi
    Shu, Feng
    Chen, Xinkai
    SMART MATERIALS AND STRUCTURES, 2022, 31 (09)
  • [32] Blood flow analysis of the head and lower limbs by the laser doppler blood flowmeter during LDL apheresis
    Ebihara, Itaru
    Sato, Takashi
    Hirayama, Kouichi
    Seki, Masanori
    Enami, Terukazu
    Kawahara, Hirohisa
    Niwayama, Jun
    Miyahara, Takaaki
    Shibata, Masamichi
    Maeda, Nobuki
    Kurosawa, Takesi
    Yamagata, Kunihiro
    Sanaka, Tsutomu
    THERAPEUTIC APHERESIS AND DIALYSIS, 2007, 11 (05) : 325 - 330
  • [33] CONSTITUTIVE MODELING OF PATTERNED LIQUID CRYSTAL ELASTOMER FOR ACTIVE FLOW CONTROL
    Beblo, Richard
    Settle, Michael
    Guin, Tyler
    White, Timothy
    Reich, Gregory
    PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, 2017, VOL 2, 2017,
  • [34] Flow simulation and hemolysis modeling for a blood centrifuge device
    Schenkel, A.
    Deville, M. O.
    Sawley, M. L.
    Hagmann, P.
    Rochat, J. -D.
    COMPUTERS & FLUIDS, 2013, 86 : 185 - 198
  • [35] EFFECT OF INTERMITTENT COMPRESSION ON BLOOD AND LYMPH-FLOW RATES IN THE LOWER-LIMBS
    ROZTOCIL, K
    PREROVSKY, I
    OLIVA, I
    VASA-JOURNAL OF VASCULAR DISEASES, 1979, 8 (04): : 346 - 348
  • [36] Effect of transcutaneous electrical spinal cord stimulation on the blood flow in the skin of lower limbs
    Lobov G.I.
    Shcherbakova N.A.
    Gorodnichev R.M.
    Grishin A.A.
    Gerasimenko Y.P.
    Moshonkina T.R.
    Human Physiology, 2017, 43 (5) : 518 - 523
  • [37] BLOOD-FLOW OF THE IPSILATERAL AND CONTRALATERAL LOWER-LIMBS AFTER ISOMETRIC CONTRACTION
    KITAMURA, K
    YASUDA, Y
    MIYAMURA, M
    MATSUI, H
    JAPANESE JOURNAL OF PHYSIOLOGY, 1980, 30 (02): : 301 - 304
  • [38] PLETHYSMOGRAPHIC INDEXES OF THE DIRECT AND RETROGRADE BLOOD-FLOW IN VEINS OF THE LOWER-LIMBS
    ZAVYALOV, ED
    KLINICHESKAYA MEDITSINA, 1982, 60 (04): : 89 - 93
  • [39] EFFECTS OF VACUUM-COMPRESSION THERAPY ON BLOOD-FLOW IN LOWER-LIMBS
    RITHALIA, SVS
    GONSALKORALE, M
    EDWARDS, I
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1989, 12 (03) : 320 - 323
  • [40] Using Wavelet Analysis of Blood Flow Oscillations to Investigate Differences in Skin Blood Flow Regulations Between the Upper and Lower Limbs
    Guo, Jiaqi
    Lin, Songmei
    Hung, Isabella Yu-Ju
    Lin, Cheng-Feng
    Mo, Pu-Chun
    Sun, Pu
    Jan, Yih-Kuen
    SKIN RESEARCH AND TECHNOLOGY, 2024, 30 (10)