The clinical outcomes of scaphoid nonunion treated with a precisely processed autologous bone screw: a case series

被引:1
|
作者
Manako, Takuya [1 ]
Imade, Shinji [1 ]
Yamagami, Nobuo [1 ]
Yamamoto, Soichiro [1 ]
Uchio, Yuji [1 ]
机构
[1] Shimane Univ, Fac Med, Dept Orthopaed Surg, 89-1 Enya, Izumo, Shimane 6938501, Japan
关键词
Bone graft; Numerically controlled lathe; Sterile condition; Tibial cortex; Donor site disorder; UNICORTICAL TIBIAL GRAFTS; BIODEGRADABLE IMPLANTS; BIOMECHANICAL ANALYSIS; CORTICAL BONE; FIXATION; FRACTURES; STRENGTH;
D O I
10.1007/s00402-021-04092-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Metal implants and bioabsorbable implants are frequently used in orthopaedic surgery, but they have some disadvantages. The usefulness of autologous bone has been described, and a method to precisely process autologous bone into implants such as screws and apply the implants clinically has been desired. We created a new system for manufacturing autologous bone screws during surgery and report five cases of scaphoid nonunion treated with precise autologous bone screws made from the tibial cortex using the new system. Patients and methods From 2012 through 2017, seven patients were diagnosed with scaphoid nonunion at our hospital and based on the inclusion/exclusion criteria, five of them were analyzed herein. The surgery was performed according to Zaidemberg's technique. The bone screw in each case was made from autologous tibial cortex using a numerically controlled lathe (model MTS4, Nano Co., Yokohama, Japan) under sterile conditions. The change in each patient's modified Mayo wrist score between the preoperative examination and at the final survey was determined, as were complications. Results The median modified Mayo wrist score improved significantly from 65 to 95 points. All patients who were followed for > 2 years fused at a median duration of 3.5 months. Bone regeneration was confirmed at the donor sites in all cases. One fracture at the donor site occurred as a severe complication. Conclusions Precisely shaped autologous bone screws manufactured by a computer-assisted machine, together with a vascularized bone graft, may be a useful technique for treating scaphoid nonunions; these screws had good stability and bone replacement. Careful observation of the donor site is required.
引用
收藏
页码:627 / 635
页数:9
相关论文
共 50 条
  • [31] Wrist function recovery course in patients with scaphoid nonunion treated with combined volar bone grafting and a dorsal antegrade headless screw
    Yeh, Chen-Wei
    Hsu, Cheng-En
    Wang, Wei-Chih
    Chiu, Yung-Cheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [32] Scaphoid Nonunions Treated with Nonvascularized Bone Grafting and Screw Fixation
    Zondervan, Robert L.
    Childe, Jessica R.
    Kustasz, Robin
    Hornbach, Erich E.
    JOURNAL OF WRIST SURGERY, 2024, 13 (01) : 24 - 30
  • [33] Can Any Proximal Pole Scaphoid Fracture Nonunion be Treated with Arthroscopic Bone Grafting? A Series of Case Reports of Successes in Challenging and Unique Cases
    Choudhury, Muntasir Mannan
    JOURNAL OF WRIST SURGERY, 2024,
  • [34] Nonunion of the scaphoid treated by anterior vascularized bone graft:a review of 26 cases
    Mohamed Faouzi Hamdi
    Karim Amara
    Lamjed Tarhouni
    Sayed Baccari
    中华创伤杂志(英文版), 2011, (04)
  • [35] Scaphoid Waist Nonunion With Humpback Deformity Treated Without Structural Bone Graft
    Cohen, Mark S.
    Jupiter, Jesse B.
    Fallahi, Kianoosh
    Shukla, Sanjai K.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (04): : 701 - 705
  • [36] Nonunion of the scaphoid treated by anterior vascularized bone graft: a review of 26 cases
    Hamdi, Mohamed Faouzi
    Amara, Karim
    Tarhouni, Lamjed
    Baccari, Sayed
    CHINESE JOURNAL OF TRAUMATOLOGY, 2011, 14 (04) : 205 - 208
  • [37] Treatment of scaphoid nonunion with nonvascularized distal radius bone graft and headless cannulated compression screw
    Yamak, Kamil
    Altay, Taskin
    Ozan, Firat
    Kayali, Cemil
    Karahan, Huseyin G.
    CHIRURGIA-ITALY, 2020, 33 (06): : 289 - 294
  • [38] Scaphoid nonunion: does open reduction, bone grafting and Herbert screw fixation justify the treatment?
    Mani, K. C. Kapil
    Acharya, Parimal
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (05) : 1099 - 1106
  • [39] Autologous bone grafting and double screw fixation for unstable scaphoid nonunions with cavitary bone loss
    Ek, Eugene T.
    Johnson, Paul R.
    Bohan, Carmel M.
    Padmasekara, Gayan
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2021, 46 (02) : 205 - 206
  • [40] Osteosynthesis with autologous dual bone graft for nonunion of midshaft clavicle fractures: clinical and radiological outcomes
    Lim, Sungjoon
    Cho, Euihwan
    Chun, Jae-Myeung
    Jeon, In-Ho
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (01): : 159 - 165