Diffuse reflectance spectroscopy of the spine: improved breach detection with angulated fibers

被引:3
|
作者
Losch, Merle S. [1 ]
Kardux, Famke [1 ]
Dankelman, Jenny [1 ]
Hendriks, Benno H. W. [1 ,2 ]
机构
[1] Delft Univ Technol, Dept Biomech Engn, Delft, Netherlands
[2] Royal Philips NV, Philips Res, Image Guided Therapy & Ultrasound Devices & Syst D, Eindhoven, Netherlands
关键词
PEDICLE SCREW PLACEMENT; TISSUE OPTICAL-PROPERTIES; IMAGE GUIDANCE; ULTRASOUND; BONE; ACCURACY; FIXATION;
D O I
10.1364/BOE.471725
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accuracy in spinal fusion varies greatly depending on the experience of the physician. Real-time tissue feedback with diffuse reflectance spectroscopy has been shown to provide cortical breach detection using a conventional probe with two parallel fibers. In this study, Monte Carlo simulations and optical phantom experiments were conducted to investigate how angulation of the emitting fiber affects the probed volume to allow for the detection of acute breaches. Difference in intensity magnitude between cancellous and cortical spectra increased with the fiber angle, suggesting that outward angulated fibers are beneficial in acute breach scenarios. Proximity to the cortical bone could be detected best with fibers angulated at Of = 45 & DEG; for impending breaches between Op = 0 & DEG; and Op = 45 & DEG;. An orthopedic surgical device comprising a third fiber perpendicular to the device axis could thus cover the full impending breach range from Op = 0 & DEG; to Op = 90 & DEG;.
引用
收藏
页码:739 / 750
页数:12
相关论文
共 50 条
  • [31] Diffuse reflectance patterns in cervical spectroscopy
    Marín, NM
    Milbourne, A
    Rhodes, H
    Ehlen, T
    Miller, D
    Benedet, L
    Richards-Kortum, R
    Follen, M
    GYNECOLOGIC ONCOLOGY, 2005, 99 (03) : S116 - S120
  • [32] Neurosurgical guidance with diffuse reflectance spectroscopy
    Eslami, Pegah
    DePaoli, Damon
    Goetz, Laurent
    Parent, Martin
    Cote, Daniel
    2021 PHOTONICS NORTH (PN), 2021,
  • [33] DIFFUSE REFLECTANCE SPECTROSCOPY - IMPORTANT DEVELOPMENTS
    MILOSEVIC, M
    MIKROCHIMICA ACTA, 1988, 2 (1-6) : 137 - 139
  • [34] HIGH TEMPERATURE DIFFUSE REFLECTANCE SPECTROSCOPY
    WENDLANDT, WW
    SMITH, JP
    FRANKE, PH
    ANALYTICAL CHEMISTRY, 1963, 35 (01) : 105 - &
  • [35] DIFFUSE-REFLECTANCE SPECTROSCOPY IN THE INFRARED
    MAULHARDT, H
    KUNATH, D
    TALANTA, 1982, 29 (03) : 237 - 241
  • [36] Optical detection of wound infection in vivo by near infrared diffuse reflectance spectroscopy
    Wang, Pin
    Wang, Jie
    Yin, Meifang
    Li, Yongming
    Wu, Jun
    SPECTROSCOPY LETTERS, 2017, 50 (10) : 566 - 571
  • [37] Diagnostic power of diffuse reflectance spectroscopy for targeted detection of breast lesions with microcalcifications
    Soares, Jaqueline S.
    Barman, Ishan
    Dingari, Narahara Chari
    Volynskaya, Zoya
    Liu, Wendy
    Klein, Nina
    Plecha, Donna
    Dasari, Ramachandra R.
    Fitzmaurice, Maryann
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (02) : 471 - 476
  • [38] Detection of calcite in quartz with diffuse reflectance Fourier transform infrared spectroscopy.
    McGahee, EE
    Jones, R
    Capps, R
    Myers, SA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U193 - U193
  • [39] Detection of internal quality in kiwi with time-domain diffuse reflectance spectroscopy
    Valero, C
    Ruiz-Altisent, M
    Cubeddu, R
    Pifferi, A
    Taroni, P
    Torricelli, A
    Valentini, G
    Johnson, DS
    Dover, CJ
    APPLIED ENGINEERING IN AGRICULTURE, 2004, 20 (02) : 223 - 230
  • [40] Detection of Benzoyl Peroxide in Wheat Flour by NIR Diffuse Reflectance Spectroscopy Technique
    Zhang Zhi-yong
    Li Gang
    Liu Hai-xue
    Lin Ling
    Zhang Bao-ju
    Wu Xiao-rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (12) : 3260 - 3263