Cement Augmented Pedicle Screw Instrumentation in Pediatric Spine Surgery

被引:1
|
作者
Mraja, Hamisi Mwarindano [1 ]
Gok, Halil [1 ]
Daadour, Inas Mohamed Fawzy [1 ]
Ulusoy, Onur Levent [2 ]
Sanli, Tunay [1 ]
Karadereler, Selhan [1 ]
Enercan, Meric [3 ]
Hamzaoglu, Azmi [1 ]
机构
[1] Scoliosis Spine Ctr Istanbul, Istanbul, Turkiye
[2] Istanbul Florence Nightingale Hosp, Radiol Dept, Istanbul, Turkiye
[3] Demiroglu Bilim Univ, Scoliosis Spine Ctr Istanbul, Istanbul, Turkiye
关键词
Cement augmentation; Osteoporosis; Pediatric scoliosis; Pedicle screw; Vertebroplasty; BONE-MINERAL DENSITY; PERCUTANEOUS VERTEBROPLASTY; POLYMETHYLMETHACRYLATE; OSTEOPOROSIS; CHILDREN; ADOLESCENTS; FIXATION;
D O I
10.1016/j.wneu.2023.03.006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
-BACKGROUND: Osteoporosis in pediatric patients is rare. Osteomalacia and osteoporosis are known to develop in syndromic or neuromuscular scoliosis children. Spinal deformity surgery for pediatric patients with osteoporosis is challenging, associated with pedicle screw (PS) failure and compression fractures. Cement augmentation of PS is one several measures to prevent screw failure. It provides additional pull-out strength to the PS in the osteoporotic vertebra. METHODS: In 2010-2020, an analysis of pediatric pa-tients who had cement augmentation of PS with a minimum follow-up of 2 years was performed. Radiological and clinical evaluations were analyzed. RESULTS: The study included 7 patients (4 girls, 3 boys) with a mean age of 13 years (range, 10-14 years) and mean follow-up of 3 years (range, 2-3 years). Only 2 patients -nderwent revision surgery. Total number of cement augmented PSs was 52 with an average of 7 per patient. Only 1 patient had lower instrumented vertebra verte-broplasty. There was no PS pull-out in the cement augmented levels, and there were no neurological deficits or pulmonary cement embolisms. One patient developed a PS pull-out in uncemented levels. Two patients developed compression fractures, one, with osteogenesis imperfecta, in the supra-adjacent levels (upper instrumented vertebra + 1 and upper instrumented vertebra + 2), and the other, with neuromuscular scoliosis, in the uncemented segments. -CONCLUSIONS: In this study, all cement augmented PSs provided satisfactory radiological outcomes without PS pull-out and adjacent vertebral compression fracture. In pediatric spine surgery, in osteoporotic patients with a poor bone purchase, cement augmentation may be used, especially in high-risk patients with osteogenesis imper-fecta, neuromuscular scoliosis, and syndromic scoliosis.
引用
收藏
页码:E126 / E130
页数:5
相关论文
共 50 条
  • [1] Expandable pedicle screw instrumentation plus cement augmentation in surgery for severely osteoporotic spine
    吴子祥
    China Medical Abstracts(Surgery), 2011, 20 (02) : 89 - 90
  • [2] Anterior exposures of the pediatric spine and posterior pedicle screw instrumentation
    Hedequist, Daniel
    Emans, John
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2007, 18 (04) : 681 - +
  • [3] Augmented reality in minimally invasive spine surgery: early efficiency and complications of percutaneous pedicle screw instrumentation
    Butler, Alexander J.
    Colman, Matthew W.
    Lynch, James
    Phillips, Frank M.
    SPINE JOURNAL, 2023, 23 (01): : 27 - 33
  • [4] Percutaneous, PMMA-augmented, pedicle screw instrumentation of thoracolumbar ankylotic spine fractures
    Buxbaum, Rina E.
    Shani, Adi
    Mulla, Hani
    Rod, Alon
    Rahamimov, Nimrod
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [5] Percutaneous, PMMA-augmented, pedicle screw instrumentation of thoracolumbar ankylotic spine fractures
    Rina E. Buxbaum
    Adi Shani
    Hani Mulla
    Alon Rod
    Nimrod Rahamimov
    Journal of Orthopaedic Surgery and Research, 16
  • [6] Surgical Treatment of Scoliosis in Osteogenesis Imperfecta With Cement-augmented Pedicle Screw Instrumentation
    Yilmaz, Guney
    Hwang, Steven
    Oto, Murat
    Kruse, Richard
    Rogers, Kenneth J.
    Bober, Michael B.
    Cahill, Patrick J.
    Shah, Suken A.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (03): : 174 - 180
  • [7] The cement leakage in cement-augmented pedicle screw instrumentation in degenerative lumbosacral diseases: a retrospective analysis of 202 cases and 950 augmented pedicle screws
    Guo, Hui-zhi
    Tang, Yong-chao
    Guo, Dan-qing
    Zhang, Shun-cong
    Li, Yong-xian
    Mo, Guo-ye
    Luo, Pei-jie
    Zhou, Ten-peng
    Ma, Yan-huai
    Liang, De
    Jiang, Xiao-bing
    EUROPEAN SPINE JOURNAL, 2019, 28 (07) : 1661 - 1669
  • [8] The cement leakage in cement-augmented pedicle screw instrumentation in degenerative lumbosacral diseases: a retrospective analysis of 202 cases and 950 augmented pedicle screws
    Hui-zhi Guo
    Yong-chao Tang
    Dan-qing Guo
    Shun-cong Zhang
    Yong-xian Li
    Guo-ye Mo
    Pei-jie Luo
    Ten-peng Zhou
    Yan-huai Ma
    De Liang
    Xiao-bing Jiang
    European Spine Journal, 2019, 28 : 1661 - 1669
  • [9] Pedicle screw stacking: A technical note on instrumentation of lumbar spine with a broken pedicle screw
    Uvaraj, Nalli Ramanathan
    Jill, Jvaghar
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2021, 23
  • [10] Machine vision augmented reality for pedicle screw insertion during spine surgery
    Nguyen, Nhu Q.
    Priola, Stefano M.
    Ramjist, Joel M.
    Guha, Daipayan
    Dobashi, Yuta
    Lee, Kenneth
    Lu, Michael
    Androutsos, Dimitrios
    Yang, Victor
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 72 : 350 - 356