A Factorial Design and Simplex Optimization of a Bismuth Film Glassy Carbon Electrode for Cd(II) and Pb(II) Determination

被引:2
|
作者
Finsgar, Matjaz [1 ]
Rajh, Barbara [1 ]
机构
[1] Univ Maribor, Fac Chem & Chem Engn, Smetanova Ul 17, Maribor 2000, Slovenia
关键词
electroanalysis; bismuth modified glassy carbon electrode; heavy metals; factorial design; simplex optimization; ANODIC-STRIPPING VOLTAMMETRY; TRACE HEAVY-METALS; IONS; PB; MERCURY; CD;
D O I
10.3390/chemosensors11020129
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents the use of a fractional two-level factorial design to determine the influence of different factors involved in the development of the square-wave anodic stripping voltammetry method. A fractional factorial design of eight different electrodes using a bismuth film glassy carbon electrode (BiFGCE) was formulated, and the impact of the factors on the analytical performance of the electrodes was determined. The impact of six factors (deposition potential, deposition time, potential step, amplitude, frequency, and the concentration of Bi(III)) was tested for Cd(II) and Pb(II) determination. Next, simplex optimization was carried out to improve the electroanalytical performance of the BiFGCE. The objective of simplex optimization was to simultaneously obtain a low limit of quantification, a wide linear concentration range, high sensitivity, high accuracy, and good precision for the new BiFGCE developed. By employing the latter approach, an optimization criterion was improved by several orders of magnitude. Moreover, the possible interference effect of different species was tested using two optimized BiFGCE. Furthermore, a real sample analysis of tap water with two optimized BiFGCEs was also carried out.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Voltammetric Determination of Pb(II) and Cd(II) Ions in Well Water Using a Sputtered Bismuth Screen-Printed Electrode
    Sosa, Velia
    Serrano, Nulria
    Arino, Cristina
    Diaz-Cruz, Jose Manuel
    Esteban, Miquel
    ELECTROANALYSIS, 2014, 26 (10) : 2168 - 2172
  • [42] A novel electrochemical sensor based on a glassy carbon electrode modified with dendrimer functionalized magnetic graphene oxide for simultaneous determination of trace Pb(II) and Cd(II)
    Baghayeri, Mehdi
    Alinezhad, Heshmatollah
    Fayazi, Maryam
    Tarahomi, Mehrasa
    Ghanei-Motlagh, Reza
    Maleki, Behrooz
    ELECTROCHIMICA ACTA, 2019, 312 : 80 - 88
  • [43] Simultaneous Determination of Cd(II) and Pb(II) Based on Bismuth Film/Carboxylic Acid Functionalized Multi-Walled Carbon Nanotubes-β-cyclodextrin-Nafion Nanocomposite Modified Electrode
    Zhao, Guo
    Wang, Hui
    Liu, Gang
    Wang, Zhiqiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (10): : 8109 - 8122
  • [44] Ion Exchange Resin Modified Carbon Paste Electrode Applied to Simultaneous Determination of Cd (II) and Pb (II)
    de Almeida, Leandro Silva
    Maciel, Juliana Villela
    Sant'Anna Cadaval Junior, Tito Roberto
    Dias, Daiane
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (02)
  • [45] Electrochemical determination of Cd(II) and Pb(II) in mining effluents using a bismuth-coated carbon fiber microelectrode
    Pena, Roselyn C.
    Cornejo, Lorena
    Bertotti, Mauro
    Brett, Christopher M. A.
    ANALYTICAL METHODS, 2018, 10 (29) : 3624 - 3630
  • [46] Sputtered bismuth screen-printed electrode: A promising alternative to other bismuth modifications in the voltammetric determination of Cd(II) and Pb(II) ions in groundwater
    Sosa, Vella
    Serrano, Nuria
    Arino, Cristina
    Manuel Diaz-Cruz, Jose
    Esteban, Miguel
    TALANTA, 2014, 119 : 348 - 352
  • [47] Simple and Sensitive Voltammetric Procedure for Determination of Cd(II) and Pb(II) Using Bismuth-Coated Screen-Printed Carbon Electrode Prepared with Mediator
    Tyszczuk-Rotko, Katarzyna
    Domanska, Katarzyna
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (07) : H537 - H544
  • [48] Simultaneous Determination of Copper(II), Lead(II) and Zinc(II) at Bismuth Film Electrode by Multivariate Calibration
    Alves, Georgina M. S.
    Magalhaes, Julia M. C. S.
    Soares, Helena M. V. M.
    ELECTROANALYSIS, 2011, 23 (06) : 1410 - 1417
  • [49] Preparation of dendritic bismuth film electrodes and their application for detection of trace Pb (II) and Cd (II)
    Zhou, Huizhu
    Hou, Huanhuan
    Dai, Lei
    Li, Yuehua
    Zhu, Jing
    Wang, Ling
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2016, 24 (03) : 410 - 414
  • [50] Lithographically fabricated disposable bismuth-film electrodes for the trace determination of Pb(II) and Cd(II) by anodic stripping voltammetry
    Kokkinos, Christos
    Economou, Anastasios
    Raptis, Ioannis
    Efstathiou, Constantinos E.
    ELECTROCHIMICA ACTA, 2008, 53 (16) : 5294 - 5299