Characteristics of optically stimulated luminescent dosimeter of beryllium oxide in BNCT irradiation field

被引:2
|
作者
Matsubayashi, Nishiki [1 ]
Hu, Naonori [2 ,3 ]
Takata, Takushi [2 ]
Sasaki, Akinori [1 ]
Mukawa, Tetsuya [4 ]
Suga, Keita [4 ]
Sakurai, Yoshinori [2 ]
Tanaka, Hiroki [2 ]
机构
[1] Kyoto Univ, Kyoto Univ Katsura, Grad Sch Engn, Kyoto Nishikyo Ku, Kyoto 6158246, Japan
[2] Kyoto Univ, Inst Integrated Radiat & Nucl Sci, Particle Radiat Oncol Res Ctr, 2-Asashiro Nishi, Kumatori, Osaka 5900494, Japan
[3] Osaka Med & Pharmaceut Univ, Educ Fdn, Kansai BNCT Med Ctr, Daigakumachi, Takatsuki, Osaka 5690801, Japan
[4] Sumitomo Heavy Ind Ltd, Osaki Shinagawa, Tokyo 1416025, Japan
关键词
Boron neutron capture therapy; BNCT; Optically stimulated luminescent dosimeter; Beryllium oxide; OSLD; NEUTRON-CAPTURE THERAPY; RECURRENT; FACILITY; SYSTEM; HEAD;
D O I
10.1016/j.radmeas.2023.106900
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The irradiation fields in boron neutron capture therapy (BNCT) consist of neutrons with a wide energy range and undesired high-intensity gamma-rays. As the thermoluminescent dosimeter (TLD) used for BNCT dosimetry is out of production, a new type of gamma-ray dosimeter is required for the quality assurance (QA) of the treatment. Therefore, in this study, an optically stimulated luminescent dosimeter (OSLD) made of BeO ceramic was selected and its use in the field of BNCT was investigated. The performance of the dosimeter was tested and the effect of a thermal neutron on the gamma-ray dose obtained by the OSLD was measured. The OSLDs had a good gamma-ray dose linearity of approximately 300 mGy corresponding to the dose in the quality assurance procedure of BNCT, and the thermal neutron sensitivity of the OSLD was less than that of TLD.
引用
下载
收藏
页数:5
相关论文
共 46 条
  • [21] Feasibility study of an optically-stimulated luminescent nanodot dosimeter (OSLnD) in high-energy photon beams
    Kim, Jin-Young
    Park, Sung-Kwang
    Kim, Yon-Lae
    Suh, Tae-Suk
    Shin, Jung-Wook
    Oh, Kyoung-Min
    Nam, Sang-Hee
    Kim, Jong-Eon
    Min, Byung-In
    Jo, Sun-Mi
    Oh, Won-Young
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (07) : 1159 - 1163
  • [22] Practical time considerations for optically stimulated luminescent dosimetry (OSLD) in total body irradiation
    Butson, Martin
    Haque, Mamoon
    Smith, Leon
    Butson, Ethan
    Odgers, David
    Pope, Dane
    Gorjiana, Tina
    Whitaker, May
    Morales, Johnny
    Hong, Angela
    Hill, Robin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 167 - 171
  • [23] Feasibility study of an optically-stimulated luminescent nanodot dosimeter (OSLnD) in high-energy photon beams
    Jin-Young Kim
    Sung-Kwang Park
    Yon-Lae Kim
    Tae-Suk Suh
    Jung-Wook Shin
    Kyoung-Min Oh
    Sang-Hee Nam
    Jong-Eon Kim
    Byung-In Min
    Sun-Mi Jo
    Won-Young Oh
    Journal of the Korean Physical Society, 2014, 65 : 1159 - 1163
  • [24] Practical time considerations for optically stimulated luminescent dosimetry (OSLD) in total body irradiation
    Martin Butson
    Mamoon Haque
    Leon Smith
    Ethan Butson
    David Odgers
    Dane Pope
    Tina Gorjiana
    May Whitaker
    Johnny Morales
    Angela Hong
    Robin Hill
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 167 - 171
  • [25] In Vivo Dose Measurements for Total Body Irradiation Using Optically Stimulated Luminescent Dosimeters
    Esquivel, C.
    Smith, M.
    Stathakis, S.
    Gutierrez, A.
    Shi, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [26] Design of a novel optically stimulated luminescent dosimeter using alkaline earth sulfides doped with SrS:Eu,Sm materials
    Liu, Yanping
    Chen, Zhaoyang
    Fan, Yanwei
    Ba, Weizhen
    Lu, Wu
    Guo, Qi
    Pan, Shilie
    Chang, Aimin
    Tang, Xinqiang
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2008, 18 (10) : 1203 - 1207
  • [27] Dosimetric calibration of nanodot optically stimulated luminescent dosimeter for intraoperative radiotherapy with low-energy X-rays
    Yeonho Choi
    Jiwon Sung
    Kwangwoo Park
    Ho Lee
    Journal of the Korean Physical Society, 2022, 81 : 1100 - 1106
  • [29] Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy
    Hasegawa, Hiroaki
    Sato, Masanori
    Tanaka, Hiroshi
    PLOS ONE, 2015, 10 (07): : e0132154
  • [30] THERMALLY STIMULATED EXOELECTRON EMISSION AND OPTICALLY STIMULATED EXOELECTRON EMISSION OF LASER EVAPORATED BERYLLIUM-OXIDE THIN-FILMS
    MITRIKOV, M
    DIMITROV, D
    METEV, S
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1984, 17 (07) : 1563 - 1566