Enhancing the seismic resilience of structures by using optimum combination of tuned mass damper inerter and negative stiffness damper

被引:3
|
作者
Kiran, K. K. [1 ]
Ahmad, Shamsad [2 ,3 ]
Al-Osta, Mohammed A. [2 ,3 ]
Bahraq, Ashraf A. [3 ]
机构
[1] SJB Inst Technol, Dept Civil Engn, Bangalore, Karnataka, India
[2] King Fahd Univ Petr & Minerals, Dept Civil & Environm Engn, Dhahran 31261, Saudi Arabia
[3] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Construct & Bldg Mat, Dhahran 31261, Saudi Arabia
关键词
Tuned mass damper; TMDI with negative stiffness devices; H-2 optimization technique; H-infinity optimization technique; Stability maximization criterion; OF-THE-ART; VIBRATION CONTROL; ABSORBER PARAMETERS; ENERGY-DISSIPATION; FREEDOM STRUCTURE; OPTIMAL-DESIGN; SYSTEMS; PERFORMANCE; OPTIMIZATION; FORMULAS;
D O I
10.1016/j.istruc.2023.105253
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a study on optimizing the combination of a tuned mass damper inerter and a negative stiffness damper (TMDI-NSD) for better performance of structures against seismic actions. The experimental data obtained from the literature were used in the optimization of a hybrid combination of TMDI-NSD subjected to harmonic excitation considering different stability maximization criteria (SMC). The H-2 optimization technique was used to obtain the optimum tunning parameter using the numerical method, while the closed form of the optimum technique was used to obtain the optimum tunning parameter through the SMC optimization tech-nique. The maximum dynamic amplification factor (DAFmax) was considered for a comparison of TMDI-NSD. The results show that the performance of a TMDI-NSD combination is superior compared to that of a TMD. In addition, it is found that the performance of SMC is less compared to H-2 & H-infinity criteria, but the performance of H-2 & H-infinity is equivalent. The DAFmax value increases with the increase in the mass ratio for the TMDI-NSD combination, whereas it declines with the rise in the mass ratio for TMD. Besides, the performance of the damped primary system under seismic load with and without the TMDI-NSD combination was analyzed. Twenty real earthquake ground motion data were considered in the analysis. The response of the primary system mitigated with the TMD and TMDI-NSD combination was evaluated in terms of the broad frequency range efficiency and peak value. It is observed that the damped primary system with TMDI-NSD combination using under-optimization criteria is superior to TMDI-NSD with respect to the displacement response. However, when considering the acceleration response, the SMC performs better compared to H-2 & H-infinity optimization criteria. The acceleration and displacement response for the primary structural system is reduced by 60% and 75%, respectively, by using TMDI-NSD of SMC optimization. Finally, the investigation of the single primary degree of freedom for a system with a TMDI-NSD combination indicates that all three optimization criteria under real seismic excitation perform better.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] The Seismic Mitigation Design of Tuned Inerter Damper for Building Structure
    Liu L.
    Tan P.
    Yan W.
    Zhou F.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2018, 38 (04): : 751 - 757
  • [42] Tandem tuned mass damper inerter for passive control of buildings under seismic loads
    Farzam, Maziar Fahimi
    Jalali, Himan Hojat
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (09):
  • [43] Optimal design and seismic performance of tuned mass damper inerter (TMDI) for structures with nonlinear base isolation systems
    De Domenico, Dario
    Ricciardi, Giuseppe
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (12): : 2539 - 2560
  • [44] An optimum design methodology of active tuned mass damper for asymmetric structures
    Li, Chunxiang
    Li, Jinhua
    Qu, Yan
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2010, 24 (03) : 746 - 765
  • [45] Optimum design of base-isolated structure equipped with variant tuned mass damper inerter
    Ye, Kun
    Yang, Qi-Fan
    Chen, Zhen-Ming
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2024, 37 (08): : 1368 - 1376
  • [46] Comparative Studies on Structures with a Tuned Mass Damper and a Particle Damper
    Lu, Zheng
    Li, Kun
    Zhou, Ying
    JOURNAL OF AEROSPACE ENGINEERING, 2018, 31 (06)
  • [47] Optimum design of tuned mass damper for footbridge
    Key Laboratory of Civil Engineering Safety and Durability of China Ministry of Education, Tsinghua University, Beijing 100084, China
    不详
    Gongcheng Lixue, 9 (133-140+156):
  • [48] High performance active tuned mass damper inerter for structures under the ground acceleration
    Li, Chunxiang
    Cao, Liyuan
    EARTHQUAKES AND STRUCTURES, 2019, 16 (02) : 149 - 163
  • [49] Effects of play and inerter nonlinearities on the performance of tuned mass damper
    Brzeski, P.
    Perlikowski, P.
    NONLINEAR DYNAMICS, 2017, 88 (02) : 1027 - 1041
  • [50] Performance of Numerically Optimized Tuned Mass Damper with Inerter (TMDI)
    Weber, Felix
    Borchsenius, Fredrik
    Distl, Johann
    Braun, Christian
    APPLIED SCIENCES-BASEL, 2022, 12 (12):