Reduced Graphene Oxide Electrolyte-Gated Transistor Immunosensor with Highly Selective Multiparametric Detection of Anti-Drug Antibodies

被引:11
|
作者
Sensi, Matteo [1 ]
de Oliveira, Rafael Furlan [2 ,3 ]
Berto, Marcello [1 ]
Palmieri, Marina [1 ]
Ruini, Emilio [1 ]
Livio, Pietro Antonio [2 ]
Conti, Andrea [4 ]
Pinti, Marcello [1 ]
Salvarani, Carlo [5 ]
Cossarizza, Andrea [6 ]
Cabot, Joan M. [7 ]
Ricart, Jordi [7 ]
Casalini, Stefano [2 ,8 ]
Gonzalez-Garcia, Maria Begona [9 ]
Fanjul-Bolado, Pablo [9 ]
Bortolotti, Carlo Augusto [1 ]
Samori, Paolo [2 ]
Biscarini, Fabio [1 ,10 ]
机构
[1] Univ Modena & Reggio Emilia, Dept Life Sci, Via Campi 103, I-41125 Modena, Italy
[2] Univ Strasbourg, CNRS, ISIS, 8 Allee Gaspard Monge, F-67000 Strasbourg, France
[3] Brazilian Ctr Res Energy & Mat CNPEM, Brazilian Nanotechnol Natl Lab LNNano, BR-13083970 Campinas, Brazil
[4] Univ Modena & Reggio Emilia, Surg Med & Dent Dept Morphol Sci Related Transplan, Dermatol Unit, Oncol & Regenerat Med, Via Pozzo 71, I-41125 Modena, Italy
[5] Univ Modena & Reggio Emilia, Med Sch Azienda Osped Univ Policlin Modena, Rheumatol Unit, Via Pozzo 71, I-41125 Modena, Italy
[6] Univ Modena & Reggio Emilia, Dept Med & Surg Sci Children & Adults, Via Campi 287, I-41125 Modena, Italy
[7] Leitat Technol Ctr, Innovacio 2, Barcelona 08225, Spain
[8] Univ Padua, Dipartimento Sci Chim, Via Marzolo 1, I-35131 Padua, Italy
[9] Metrohm DropSens, SL Vivero Ciencias Salud, C Colegio St Domingo Guzman S-N, Oviedo 33010, Spain
[10] Ist Italiano Tecnol, Ctr Translat Neurophysiol, Via Fossato Mortara 17-19, I-44121 Ferrara, Italy
基金
巴西圣保罗研究基金会;
关键词
ADAs; EGT; immunosensors; infliximab; rGO; FIELD-EFFECT TRANSISTOR; INFLIXIMAB; TRANSPORT; SERUM;
D O I
10.1002/adma.202211352
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The advent of immunotherapies with biological drugs has revolutionized the treatment of cancers and auto-immune diseases. However, in some patients, the production of anti-drug antibodies (ADAs) hampers the drug efficacy. The concentration of ADAs is typically in the range of 1-10 pm; hence their immunodetection is challenging. ADAs toward Infliximab (IFX), a drug used to treat rheumatoid arthritis and other auto-immune diseases, are focussed. An ambipolar electrolyte-gated transistor (EGT) immunosensor is reported based on a reduced graphene oxide (rGO) channel and IFX bound to the gate electrode as the specific probe. The rGO-EGTs are easy to fabricate and exhibit low voltage operations (& LE; 0.3 V), a robust response within 15 min, and ultra-high sensitivity (10 am limit of detection). A multiparametric analysis of the whole rGO-EGT transfer curves based on the type-I generalized extreme value distribution is proposed. It is demonstrated that it allows to selectively quantify ADAs also in the co-presence of its antagonist tumor necrosis factor alpha (TNF-& alpha;), the natural circulating target of IFX.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Highly selective detection of trace Cu2+ based on polyethyleneimine-reduced graphene oxide nanocomposite modified glassy carbon electrode
    Rere Hu
    Hao Gou
    Zunli Mo
    Xiaojiao Wei
    Yawen Wang
    Ionics, 2015, 21 : 3125 - 3133
  • [42] Highly selective detection of trace Cu2+ based on polyethyleneimine-reduced graphene oxide nanocomposite modified glassy carbon electrode
    Hu, Rere
    Gou, Hao
    Mo, Zunli
    Wei, Xiaojiao
    Wang, Yawen
    IONICS, 2015, 21 (11) : 3125 - 3133
  • [43] Real-Time, Selective Detection of Pb2+ in Water Using a Reduced Graphene Oxide/Gold Nanoparticle Field-Effect Transistor Device
    Zhou, Guihua
    Chang, Jingbo
    Cui, Shumao
    Pu, Haihui
    Wen, Zhenhai
    Chen, Junhong
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (21) : 19235 - 19241
  • [44] Highly sensitive electrochemical detection of cancer biomarker based on anti-EpCAM conjugated molybdenum disulfide grafted reduced graphene oxide nanohybrid
    Jalil, Owais
    Pandey, Chandra Mouli
    Kumar, Devendra
    BIOELECTROCHEMISTRY, 2021, 138
  • [45] Highly sensitive electrochemical detection of cancer biomarker based on anti-EpCAM conjugated molybdenum disulfide grafted reduced graphene oxide nanohybrid
    Jalil, Owais
    Pandey, Chandra Mouli
    Kumar, Devendra
    Bioelectrochemistry, 2021, 138
  • [46] Au@Pd core-shell nanoparticles-decorated reduced graphene oxide: a highly sensitive and selective platform for electrochemical detection of hydrazine
    Dutta, Soumen
    Ray, Chaiti
    Mallick, Sourav
    Sarkar, Sougata
    Roy, Anindita
    Pal, Tarasankar
    RSC ADVANCES, 2015, 5 (64): : 51690 - 51700
  • [47] Ultrasensitive and Highly Selective Electrochemical Biosensor for HIV Gene Detection Based on Amino-Reduced Graphene Oxide and β-cyclodextrin Modified Glassy Carbon Electrode
    Li, Jiawen
    Jin, Xiaoyu
    Feng, Mengmeng
    Huang, Shan
    Feng, Jinrong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (03): : 2727 - 2738
  • [48] A non-covalent interaction of Schiff base copper alanine complex with green synthesized reduced graphene oxide for highly selective electrochemical detection of nitrite
    Sakthinathan S.
    Kubendhiran S.
    Chen S.-M.
    Al-Hemaid F.A.
    Liao W.C.
    Tamizhdurai P.
    Sivasanker S.
    Ajmal Ali M.
    Hatamleh A.A.
    Chen, Shen-Ming (smchen78@ms15.hinet.net), 2016, Royal Society of Chemistry (06) : 107416 - 107425
  • [49] A non-covalent interaction of Schiff base copper alanine complex with green synthesized reduced graphene oxide for highly selective electrochemical detection of nitrite
    Sakthinathan, Subramanian
    Kubendhiran, Subbiramaniyan
    Chen, Shen-Ming
    Al-Hemaid, Fahad M. A.
    Liao, Wei Cheng
    Tamizhdurai, P.
    Sivasanker, S.
    Ali, M. Ajmal
    Hatamleh, A. A.
    RSC ADVANCES, 2016, 6 (109) : 107416 - 107425
  • [50] Facile formation of nanoporous reduced graphene oxide via epoxy-based negative photoresist laser irradiation for highly sensitive and selective gas detection
    Yang, Min Seok
    Bae, Sung-Kuk
    Seo, Dong-Bum
    Lee, Kichul
    Son, Yeseul
    Kim, Soo-Hyun
    Jung, Jae-Hwan
    An, Ki-Seok
    Park, Inkyu
    Seo, Jung Hwan
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 426