Reduced Graphene Oxide Electrolyte-Gated Transistor Immunosensor with Highly Selective Multiparametric Detection of Anti-Drug Antibodies

被引:11
|
作者
Sensi, Matteo [1 ]
de Oliveira, Rafael Furlan [2 ,3 ]
Berto, Marcello [1 ]
Palmieri, Marina [1 ]
Ruini, Emilio [1 ]
Livio, Pietro Antonio [2 ]
Conti, Andrea [4 ]
Pinti, Marcello [1 ]
Salvarani, Carlo [5 ]
Cossarizza, Andrea [6 ]
Cabot, Joan M. [7 ]
Ricart, Jordi [7 ]
Casalini, Stefano [2 ,8 ]
Gonzalez-Garcia, Maria Begona [9 ]
Fanjul-Bolado, Pablo [9 ]
Bortolotti, Carlo Augusto [1 ]
Samori, Paolo [2 ]
Biscarini, Fabio [1 ,10 ]
机构
[1] Univ Modena & Reggio Emilia, Dept Life Sci, Via Campi 103, I-41125 Modena, Italy
[2] Univ Strasbourg, CNRS, ISIS, 8 Allee Gaspard Monge, F-67000 Strasbourg, France
[3] Brazilian Ctr Res Energy & Mat CNPEM, Brazilian Nanotechnol Natl Lab LNNano, BR-13083970 Campinas, Brazil
[4] Univ Modena & Reggio Emilia, Surg Med & Dent Dept Morphol Sci Related Transplan, Dermatol Unit, Oncol & Regenerat Med, Via Pozzo 71, I-41125 Modena, Italy
[5] Univ Modena & Reggio Emilia, Med Sch Azienda Osped Univ Policlin Modena, Rheumatol Unit, Via Pozzo 71, I-41125 Modena, Italy
[6] Univ Modena & Reggio Emilia, Dept Med & Surg Sci Children & Adults, Via Campi 287, I-41125 Modena, Italy
[7] Leitat Technol Ctr, Innovacio 2, Barcelona 08225, Spain
[8] Univ Padua, Dipartimento Sci Chim, Via Marzolo 1, I-35131 Padua, Italy
[9] Metrohm DropSens, SL Vivero Ciencias Salud, C Colegio St Domingo Guzman S-N, Oviedo 33010, Spain
[10] Ist Italiano Tecnol, Ctr Translat Neurophysiol, Via Fossato Mortara 17-19, I-44121 Ferrara, Italy
基金
巴西圣保罗研究基金会;
关键词
ADAs; EGT; immunosensors; infliximab; rGO; FIELD-EFFECT TRANSISTOR; INFLIXIMAB; TRANSPORT; SERUM;
D O I
10.1002/adma.202211352
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The advent of immunotherapies with biological drugs has revolutionized the treatment of cancers and auto-immune diseases. However, in some patients, the production of anti-drug antibodies (ADAs) hampers the drug efficacy. The concentration of ADAs is typically in the range of 1-10 pm; hence their immunodetection is challenging. ADAs toward Infliximab (IFX), a drug used to treat rheumatoid arthritis and other auto-immune diseases, are focussed. An ambipolar electrolyte-gated transistor (EGT) immunosensor is reported based on a reduced graphene oxide (rGO) channel and IFX bound to the gate electrode as the specific probe. The rGO-EGTs are easy to fabricate and exhibit low voltage operations (& LE; 0.3 V), a robust response within 15 min, and ultra-high sensitivity (10 am limit of detection). A multiparametric analysis of the whole rGO-EGT transfer curves based on the type-I generalized extreme value distribution is proposed. It is demonstrated that it allows to selectively quantify ADAs also in the co-presence of its antagonist tumor necrosis factor alpha (TNF-& alpha;), the natural circulating target of IFX.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] How Biorecognition Affects the Electronic Properties of Reduced Graphene Oxide in Electrolyte-Gated Transistor Immunosensors
    Sensi, Matteo
    de Oliveira, Rafael Furlan
    Berto, Marcello
    Paradisi, Alessandro
    Greco, Pierpaolo
    Bortolotti, Carlo Augusto
    Samori, Paolo
    Biscarini, Fabio
    ADVANCED FUNCTIONAL MATERIALS, 2024, 34 (19)
  • [2] Electrolyte-Gated Ionic Transistor for Highly Sensitive and Selective Iontronic Sensing
    Liu, Ying
    Xiong, Tianyi
    Ma, Wenjie
    He, Xiulan
    Jiang, Yanan
    Pan, Cong
    Yu, Ping
    Mao, Lanqun
    ACS SENSORS, 2025, 10 (01): : 480 - 487
  • [3] Approaching the Nernst Detection Limit in an Electrolyte-Gated Metal Oxide Transistor
    Lee, Seyeong
    Park, Sungjun
    Kim, Chang-Hyun
    Yoon, Myung-Han
    IEEE ELECTRON DEVICE LETTERS, 2021, 42 (01) : 50 - 53
  • [4] Anti-drug antibody detection with label-free electrolyte-gated organic field-effect transistors
    Sensi, Matteo
    Berto, Marcello
    Gentile, Sara
    Pinti, Marcello
    Conti, Andrea
    Pellacani, Giovanni
    Salvarani, Carlo
    Cossarizza, Andrea
    Bortolotti, Carlo Augusto
    Biscarini, Fabio
    CHEMICAL COMMUNICATIONS, 2021, 57 (03) : 367 - 370
  • [5] Cu-modified electrolyte-gated transistors based on reduced graphene oxide
    Hensel, Rafael Cintra
    Comisso, Nicola
    Musiani, Marco
    Sedona, Francesco
    Sambi, Mauro
    Cester, Andrea
    Lago, Nicolo
    Casalini, Stefano
    JOURNAL OF MATERIALS CHEMISTRY C, 2023, 11 (26) : 8876 - 8884
  • [6] Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
    Ishraq, Sakib
    Sun, Jianbo
    Liu, Yuxin
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (180):
  • [7] Electrolyte-Gated Organic Field-Effect Transistor for Selective Reversible Ion Detection
    Schmoltner, Kerstin
    Kofler, Johannes
    Klug, Andreas
    List-Kratochvil, Emil J. W.
    ADVANCED MATERIALS, 2013, 25 (47) : 6895 - 6899
  • [8] An Electrolyte-Gated Graphene Field-Effect Transistor for Detection of Gadolinium(III) in Aqueous Media
    Gadroy, Charlene
    Boukraa, Rassen
    Battaglini, Nicolas
    Le Derf, Franck
    Mofaddel, Nadine
    Vieillard, Julien
    Piro, Benoit
    BIOSENSORS-BASEL, 2023, 13 (03):
  • [9] Highly Sensitive Detection of Urea Using Si Electrolyte-Gated Transistor with Low Power Consumption
    Choi, Wonyeong
    Jin, Bo
    Shin, Seonghwan
    Do, Jeonghyeon
    Son, Jongmin
    Kim, Kihyun
    Lee, Jeong-Soo
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [10] Highly sensitive and selective detection of the pancreatic cancer biomarker CA 19-9 with the electrolyte-gated MoS2-based field-effect transistor immunosensor
    Rahmani, Hedyeh
    Majd, Samira Mansouri
    Salimi, Abdollah
    IONICS, 2023, 29 (09) : 3769 - 3779