Stability Domain Analysis for Islanded Microgrid Considering N-1 Contingency

被引:0
|
作者
Lasheen, Ahmed [1 ]
Sindi, Hatem F. [2 ]
Shaaban, Mostafa F. [3 ]
Zeineldin, Hatem H. [1 ,4 ]
Hamad, Basil [4 ]
Al-Durra, Ahmed [4 ]
机构
[1] Cairo Univ, Fac Engn, Elect Power Engn Dept, Cairo 12613, Egypt
[2] King Abdulaziz Univ, Elect & Comp Engn Dept, Jeddah 21589, Saudi Arabia
[3] Amer Univ Sharjah, Elect Engn Dept, Sharjah, U Arab Emirates
[4] Khalifa Univ Sci & Technol, Adv Power & Energy Ctr, Abu Dhabi, U Arab Emirates
关键词
Microgrids; Stability criteria; Power system stability; Load modeling; Contingency management; Reactive power; Transient analysis; Domain of stability; N-1; contingency; inverter-based micro-grid; DG disconnection; network disconnection; DROOP;
D O I
10.1109/ACCESS.2023.3325626
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The most popular approach used in controlling inverter-based microgrids is the droop control technique, characterized by its plug-and-play capability and independence from communication requirements. The control parameters, at the top of which the active and reactive droop gains, mp and nq, respectively, have been recently studied, evaluating their impact on stability. Furthermore, the stability domain chart is plotted in the m(p,max)-n(q) plane identifying the stable range of the microgrid, enabling the microgrid operator to choose the desired stable operating point based on frequency, voltage, and power-sharing requirements. However, the microgrid is prone to abnormal conditions, such as network disconnection, distributed generator (DG) disconnection, and load disconnection, that also affect microgrid stability. Hence, this can have an impact on the stability domain and, consequently, the choice of droops for stable operation. Therefore, in this paper, several stability domain charts are proposed, considering all various contingencies. The proposed network disconnection, DG disconnection, and load disconnection domain charts have been combined to generate an overall stability domain chart considering N - 1 contingency. The proposed N - 1 contingency chart is of crucial importance in considering the microgrid stability for both normal and abnormal operations. N - 1 contingencies can be frequent in microgrid operation due to microgrid limited space and power nature. Hereby, the inclusion of their impact on microgrid stability provides better guidance for the tuning of the control parameters. Moreover, the proposed chart is tested and validated using time-domain simulations on MATLAB, considering different operating points. The simulation results highlight the significance of the stability domain chart for selecting the DG droop gains to maintain the microgrid stability considering N - 1 contingency. Further, real-time validation of the proposed domain of stability through OPAL-RT setup is analyzed to confirm the ability of practical controllers to respond to microgrid variations conditions in real-time operation.
引用
收藏
页码:115986 / 115997
页数:12
相关论文
共 50 条
  • [31] Stability Analysis of Islanded Microgrid Based on Constant Power Load
    Li, Yinghui
    Zhong, Zhiwen
    Rong, Xingbiao
    Huang, Peng
    Wang, Xiaohuan
    Zhang, Zhe
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 1380 - 1385
  • [32] Optimal DG Placement for Power System Reliability based on N-1 Contingency Analysis
    Azhar, Noor Aliff Nazmi Bin Noor
    Mohamad, Hasmaini
    Salim, Nur Ashida
    Yasin, Zuhaila Mat
    19TH IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED 2021), 2021, : 174 - 179
  • [33] Gas and Electric Grid Unit Commitment with Coordinated N-1 Generator Contingency Analysis
    Jamei, Mahdi
    Schweitzer, Eran
    Scaglione, Anna
    Hedman, Kory W.
    2018 POWER SYSTEMS COMPUTATION CONFERENCE (PSCC), 2018,
  • [34] Fast Analysis of N-1 Contingency Screening With Uncertainty Scenarios Based on Deep Learning
    Yang Y.
    Yang Z.
    Yu J.
    Xiang M.
    Yu H.
    Wang H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (08): : 2716 - 2724
  • [35] Graph-based Preconditioning Conjugate Gradient Algorithm for "N-1" Contingency Analysis
    Zhao, Yiting
    Yuan, Chen
    Liu, Guangyi
    Grinberg, Ilya
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [36] Power flow control and N-1 contingency analysis with DSRs in unbalanced transmission networks
    Ornran, Shaimaa
    Broadwater, Robert
    Hambrick, Joshua
    Dilek, Murat
    Thomas, Chifong
    Kreikebaum, Frank
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 136 : 223 - 231
  • [37] Model and constraint-reduction method for security-constrained unit commitment considering N-1 contingency
    Wang Y.
    Bao W.
    Li Y.
    Yao S.
    Guo R.
    Lin L.
    Kuang J.
    Bao, Wei (baowei@zju.edu.cn), 1600, Electric Power Automation Equipment Press (41): : 167 - 175
  • [38] The Effect of Load Model Composition on N-1 Contingency Ranking
    Retty, Hema
    Thorp, James S.
    Centeno, Virgilio
    2015 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT), 2015,
  • [39] Adaptive Protection Algorithm Considering N-1 Contingency Situation Using Setting Groups of Directional Overcurrent Relays
    Song, Jin-Sol
    Kim, Chul-Hwan
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, 19 (08) : 4873 - 4882
  • [40] Photovoltaic Power Penetration Planning with Generator Output and Capacitor Adjustments Using PSO Considering N-1 Contingency
    Hlaing, Aye Mya Mya
    Ando, Sho
    Kawaura, Yuki
    Iwamoto, Shinichi
    2014 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (IEEE PES APPEEC), 2014,