VEGF Detection via Impedance Spectroscopy on Surface Functionalized Interdigitated Biosensor

被引:1
|
作者
Lin, Yue-Der [1 ,2 ,3 ]
Zida, Serge Ismael [1 ]
Yang, Chu-Chun [2 ]
Khung, Yit Lung [4 ]
机构
[1] Feng Chia Univ, Ph D Program Elect & Commun Engn, 100 Wenhwa Rd, Taichung 40724, Taiwan
[2] Feng Chia Univ, Masters Program Biomed Informat & Biomed Engn, 100 Wenhwa Rd, Taichung 40724, Taiwan
[3] Feng Chia Univ, Dept Automat Control Engn, 100 Wenhwa Rd, Taichung 40724, Taiwan
[4] China Med Univ, Dept Biol Sci & Technol, 100 Jingmao Rd,Sect 1, Taichung 406040, Taiwan
关键词
DNA aptamer; interdigitated sensor; impedance spectroscopy; vascular endothelial growth factor (VEGF); ENDOTHELIAL GROWTH-FACTOR; BIOMARKER;
D O I
10.3390/jfb14070365
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vascular endothelial growth factor (VEGF), a clinically important biomarker, often plays a key role in angiogenesis, would healing, tumor growth, lung development, and in retinal diseases. Hence, detecting and quantifying VEGF is deemed medically important in clinical diagnosis for many diseases. In this report, a simple yet highly cost-effective platform was proposed for VEGF protein detection using commercially available interdigitated sensors that are surface modified to present DNA optimally for VEGF capture. The dielectric characteristics between the fingers of the sensor were modulated by the negatively charged aptamer-VEGF capture, and the impedance was estimated using an impedance analyzer. Impedance-spectra tests were compared among pristine unmodified surfaces, functionalized monolayer surfaces, and aptamer-grafted surfaces in order to evaluate the efficacy of VEGF detection. From our results, the sensitivity experiments as conducted showed the ability of the interdigitated sensor to detect VEGF at a low concentration of 5 pM (200 pg/mL). The specificity of the functionalized sensor in detecting VEGF was further examined by comparing the impedance to platelet-derived growth factor, and the results confirm the specificity of the sensor. Finally, the Nyquist plot of impedance spectra was also presented to help data visualization and the overall performance of the device was found to be a highly suitable template for a smart biosensor for the detection of VEGF.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] An aptamer-based biosensor for detection of doxorubicin by electrochemical impedance spectroscopy
    Nicole Bahner
    Peggy Reich
    Dieter Frense
    Marcus Menger
    Katharina Schieke
    Dieter Beckmann
    Analytical and Bioanalytical Chemistry, 2018, 410 : 1453 - 1462
  • [22] Development of a biosensor for the detection of carcinoembryonic antigen using faradic impedance spectroscopy
    Zhu, Q
    Chai, YQ
    Yuan, R
    Wang, N
    Li, XL
    CHEMISTRY LETTERS, 2005, 34 (12) : 1682 - 1683
  • [23] Surface Functionalized Graphene Biosensor on Sapphire for Cancer Cell Detection
    Joe, Daniel J.
    Hwang, Jeonghyun
    Johnson, Christelle
    Cha, Ho-Young
    Lee, Jo-Won
    Shen, Xiling
    Spencer, Michael G.
    Tiwari, Sandip
    Kim, Moonkyung
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2016, 16 (01) : 144 - 151
  • [24] Performance Enhancement for an Impedance Biosensor with Four-wire Interdigitated Microelectrode
    Ma Jinxian
    Wu Haiyun
    Wei Yong
    Liu Hua
    Chang Ruokui
    Shan Huiyong
    Zuo Yueming
    2015 INTERNATIONAL CONFERENCE ON MANIPULATION, MANUFACTURING AND MEASUREMENT ON THE NANOSCALE (3M-NANO), 2015, : 131 - 134
  • [25] Detection of E.Coli Bacteria Using Impedance Spectroscopy and Surface Plasmon Resonance Imaging Based Biosensor
    Mejri, M. B.
    Baccar, H.
    Ktari, T.
    Aouni, M.
    Abdelghani, A.
    SENSOR LETTERS, 2011, 9 (06) : 2130 - 2132
  • [26] Modelization of interdigitated electrode sensor for impedance spectroscopy measurement
    Bourjilat, Ayoub
    Sarry, Frederic
    Kourtiche, Djilali
    Nadi, Mustapha
    2017 ELEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2017, : 118 - 122
  • [27] Interdigitated Microelectrodes Biosensor for Thyroid Stimulating Hormone Detection
    Wang, Haoxu
    Wu, Xuezhong
    Dong, Peitao
    Wang, Junfeng
    Di, Di
    Chen, Jian
    Wang, Chaoguang
    6TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2013), 2013,
  • [28] Interdigitated Electrode-Less High-Performance Macroporous Silicon Structure as Impedance Biosensor for Bacteria Detection
    Das, Ramkrishna Dev
    Dey, Abhishek
    Das, Sumantra
    RoyChaudhuri, Chirasree
    IEEE SENSORS JOURNAL, 2011, 11 (05) : 1242 - 1252
  • [29] Interdigitated microelectrode biosensor for bacterial biofilm growth monitoring by impedance spectroscopy technique in 96-well microtiter plates
    Paredes, J.
    Becerro, S.
    Arizti, F.
    Aguinaga, A.
    Del Pozo, J. L.
    Arana, S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 663 - 670
  • [30] Development of an impedance spectroscopy array biosensor
    Yu, Xiaobo
    Lu, Renji
    Xu, Danke
    Liu, Zhihong
    He, Wei
    MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (10) : S275 - S275