Measurement of 2D density profiles using a second-harmonic, dispersion interferometer

被引:1
|
作者
Chavez, C. T. [1 ]
Egly, A. [1 ]
Sepulveda, I. [1 ]
Wessel, F. J. [1 ]
机构
[1] L Egant Solut LLC, Irvine, CA 92614 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2023年 / 94卷 / 02期
关键词
HIGH TEMPORAL RESOLUTION; PLASMA;
D O I
10.1063/5.0119896
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A second-harmonic, dispersion interferometer is used to image large-area (similar or equal to 5 cm(2)) plasma-jet and gas-jet density profiles. Achromatic telescopes magnify the diameters of the primary-laser beam (1064 nm) and its second-harmonic (532 nm) before probing the sample and de-magnify the beam diameters after the sample, where the primary beam transfers its phase change to a second, second-harmonic beam, allowing the sample's dispersive-phase change to be measured between two, orthogonally polarized second harmonic beams. The telescopes produce an azimuthally symmetric, dispersive-phase shift in the sample + background phase-change image and in the background phase-change image, which is removed by digital subtraction. The interferometer's performance was verified using standard-optical components as dispersive elements (BK7 lenses and wedge plates), resolving a minimum, phase-change sensitivity of Delta phi(min) greater than or similar to 15 mrad and spatial resolution of Delta x(res) similar or equal to 100 mu m. The phase change produced by unknown-density objects (a pulsed-plasma-jet and a pulsed-gas-jet) was measured, and their data were used to recover the original, 2D density profiles using an inverse Abel transform: peak-number density, N-gas similar or equal to 6 x 10(20) cm(-3) and N-e similar or equal to 5 x 10(16) cm(-3); line-integrated density, integral N(gas)dl similar to 2 x 10(19)cm(-2) and integral N(e)dl similar to 1 x 10(16)cm(-2). The techniques and methods developed here are scalable to even larger probe-beam diameters and frame-capture rates, leading to a diagnostic capability that is well-suited for applications involving the real-time measurement of density.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Widefield quantitative phase imaging by second-harmonic dispersion interferometry
    Brandi, Fernando
    Wessel, Frank
    OPTICS LETTERS, 2020, 45 (15) : 4304 - 4307
  • [32] Second-harmonic generation taking into account dispersion of nonlinear susceptibility
    Kazantseva, EV
    Maimistov, AI
    OPTICS AND SPECTROSCOPY, 2000, 89 (05) : 772 - 782
  • [33] Shearing interferometer based on second-harmonic generation and a novel technique of n(2) direct measurements
    Drachev, VP
    Ertsenkin, SV
    Perminov, SV
    Safonov, VP
    Chubakov, PA
    APPLIED OPTICS, 1997, 36 (33): : 8622 - 8625
  • [34] Measurement of density profiles using the new infrared scanning interferometer for FTU
    Mazzotta, C.
    Tudisco, O.
    Canton, A.
    Innocente, P.
    DeBenedetti, M.
    Giovannozzi, E.
    Marocco, D.
    Micozzi, P.
    Monari, G.
    Rocchi, G.
    PHYSICA SCRIPTA, 2006, T123 : 79 - 83
  • [35] Anisotropic Second-Harmonic Generation Induced by Reduction of In-Plane Symmetry in 2D Materials with Strain Engineering
    He, Chuan
    Wu, Ruowei
    Zhu, Lipeng
    Huang, Yuanyuan
    Du, Wanyi
    Qi, Mei
    Zhou, Yixuan
    Zhao, Qiyi
    Xu, Xinlong
    JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2022, 13 (01): : 352 - 361
  • [36] Phase and Composition Engineering of Self-Intercalated 2D Metallic Tantalum Sulfide for Second-Harmonic Generation
    Han, Ziyi
    Han, Xiaocang
    Wu, Shengqiang
    Zhang, Qing
    Hu, Wenchao
    Meng, Yuan
    Liang, Yin
    Hu, Jingyi
    Li, Lin
    Zhang, Qing
    Zhang, Yanfeng
    Zhao, Xiaoxu
    Geng, Dechao
    Hu, Wenping
    ACS NANO, 2024, 18 (08) : 6256 - 6265
  • [37] 2D magnetic nanoparticle imaging using magnetization response second harmonic
    Tanaka, Saburo
    Murata, Hayaki
    Oishi, Tomoya
    Suzuki, Toshifumi
    Zhang, Yi
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2015, 383 : 170 - 174
  • [38] Assessment of HIFU lesion size using 2D second harmonic imaging
    Fujikura, K
    Abe, Y
    Otsuka, R
    Kalisz, A
    Muratore, R
    Lizzi, FL
    Homma, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 280A - 281A
  • [39] Second harmonic generation in 2D layered materials
    Zhang, Jiantian
    Zhao, Weina
    Yu, Peng
    Yang, Guowei
    Liu, Zheng
    2D MATERIALS, 2020, 7 (04):
  • [40] Air dispersion measurement by second harmonic interferometry
    Salvadé, Y
    Dändliker, R
    Zickar, M
    OPTICS FOR THE QUALITY OF LIFE, PTS 1 AND 2, 2003, 4829 : 158 - 159