Poly(riboflavin)/NaOH/graphene nanoplatelets modified graphite composite paste electrode for the determination of antioxidant rutin

被引:3
|
作者
Tigari, Girish [1 ,2 ]
Manjunatha, Jamballi G. [1 ]
Nagarajappa, Hareesha [1 ]
Tighezza, Ammar M. [3 ]
Albaqami, Munirah D. [3 ]
Sillanpaa, Mika [4 ]
机构
[1] Constituent Coll Mangalore Univ, FMKMC Coll, Dept Chem, Madikeri 571201, Karnataka, India
[2] Nitte Meenakshi Inst Technol, Dept Chem, Bangalore 560064, Karnataka, India
[3] King Saud Univ, Coll Sci, Dept Chem, Riyadh 11451, Saudi Arabia
[4] Aarhus Univ, Dept Biol & Chem Engn, Norrebrogade 44, DK-8000 Aarhus, Denmark
关键词
Electro-polymerization; Graphene nanoplatelets; Graphite; Green tea; Poly(riboflavin)/NaOH; Rutin; VOLTAMMETRIC DETERMINATION; SENSITIVE DETERMINATION; RIBOFLAVIN; ELECTROPOLYMERIZATION; QUERCETIN; SENSOR; STRATEGY;
D O I
10.1007/s11694-023-02253-4
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Instead of going for complicated and toxic materials (mercury electrodes), we have chosen riboflavin (RF), graphite, and graphene nanoplatelets (15 mg) because these are eco-friendly and efficient materials for the fabrication of electrochemical sensors. The electrochemically prepared poly(riboflavin)/NaOH/graphene-nanoplatelets modified graphite paste electrode (PRFGMGPE) and graphite paste electrode (GPE) properties before and after modification are confirmed by field emission scanning electron microscope (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), and electrochemical impedance spectroscopy (EIS). PRFGMGPE produces upsurge electrochemical reactions with quasi reversibility, but graphene-nanoplatelets modified graphite paste electrode (GMGPE), poly(riboflavin)/NaOH modified graphite paste electrode (PRFMGPE), riboflavin/NaOH/adsorbed/graphene-nanoplatelets modified graphite paste electrode (RFAGMGPE) and GPE shows the low binding capability and current response for rutin (RU). Under calibrated circumstances, PRFGMGPE detects RU in the range from 0.1 to 1.4 mu M with an impressive lower detection limit (LOD) of 4.84 x 10-9 M using differential pulse voltammetry (DPV). The performance of PRFGMGPE towards RU recognition demonstrates fine binding selectivity and anti-interference features in presence of different organic molecules and metal ions. The real-time RU testing is performed in green tea and blood serum samples with agreeable recoveries by reducing the matrix effect. Moreover, simultaneous interference was also performed with co-existing molecule hydroquinone (HQ) using the DPV technique.
引用
收藏
页码:1238 / 1252
页数:15
相关论文
共 50 条
  • [21] Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin
    Mehmeti, Eda
    Stankovic, Dalibor M.
    Chaiyo, Sudkate
    Svorc, L'ubomir
    Kalcher, Kurt
    MICROCHIMICA ACTA, 2016, 183 (05) : 1619 - 1624
  • [22] Reduced Graphene Oxide and Poly (phenylalanine) Composite Modified Electrode for the Electrochemical Determination of Vanillin
    Tesfaye, Gizaw
    Negash, Negussie
    Tessema, Merid
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (12)
  • [23] Electrochemical Determination of Riboflavin by an Ionic Liquid Modified Carbon Paste Electrode as a Sensitive Sensor
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Bagheri, Jaber
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 642 - 657
  • [24] Fabrication of nickel coated graphene oxide composite electrode for sensitive determination of Rutin
    Karabiberoglu, Sukriye Ulubay
    Dursun, Zekerya
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 815 : 76 - 85
  • [25] Graphite Oxide-Silicone Rubber Composite modified carbon paste electrode as electrochemical sensor for Propranolol determination
    Fu, Xintao
    Wang, Zepeng
    Ma, Lianxiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (04):
  • [26] Preparation of Platinum Nanoparticles-Graphene Modified Electrode and Selective Determination of Rutin
    Yu, Shu-Hong
    Zhao, Guang-Chao
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2012, 2012
  • [27] The Use of a Graphite-Silicone Rubber Composite Electrode in the Determination of Rutin in Pharmaceutical Formulation
    dos Santos, Sidney X.
    Mazo, Luiz H.
    Cavalheiro, Eder T. G.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2008, 19 (08) : 1600 - 1606
  • [28] Poly-5-Amino-1-naphthol modified pencil graphite electrode for the simultaneous electrochemical determination of Pyridoxine and Riboflavin
    Sajeevan B.
    MG G.
    Sreelekshmi
    Wilson A.
    Narayan Pillai A.
    Saraswathyamma B.
    Materials Today: Proceedings, 2023, 80 : 570 - 576
  • [29] Poly (Riboflavin) Modified Pencil Graphite for the Simultaneous Electrochemical Determination of Serotonin and Dopamine
    Krishnan, Rajasree G.
    Saraswathyamma, Beena
    Raj, T. Anjana
    Gopika, M. G.
    INTERNATIONAL CONFERENCE ON TRENDS IN MATERIAL SCIENCE AND INVENTIVE MATERIALS (ICTMIM 2020), 2020, 2259
  • [30] Voltammetric Determination of Tramadol Using a Hierarchical Graphene Oxide Nanoplatelets Modified Electrode
    Saichanapan, Jenjira
    Promsuwan, Kiattisak
    Saisahas, Kasrin
    Soleh, Asamee
    Chang, Kah Haw
    Abdullah, Ahmad Fahmi Lim
    Limbut, Warakorn
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (11)