Stray radiation dose reduction using a backscatter shield and a rectangular collimator for a handheld intraoral X-ray unit

被引:0
|
作者
Otaka, Yusei [1 ,2 ]
Harata, Yasuo [1 ]
Izawa, Maki [1 ]
Shiba, Noriyoshi [1 ]
Iwawaki, Atsushi [3 ]
Ishii, Takeru [3 ]
Ochiai, Akihiro [3 ]
Takahashi, Nobutoshi [1 ]
Saka, Hideki [2 ,3 ]
Kito, Shinji [1 ]
机构
[1] Meikai Univ, Dept Diagnost & Therapeut Sci, Div Dent Radiol, Sch Dent, 1-1 Keyakidai, Sakado, Saitama 3500283, Japan
[2] Meikai Univ, Forens Odontol Ctr, Sch Dent, 1-1 Keyakidai, Sakado, Saitama 3500283, Japan
[3] Meikai Univ, Dept Diagnost & Therapeut Sci, Div Forens Odontol, Sch Dent, 1-1 Keyakidai, Sakado, Saitama 3500283, Japan
基金
日本学术振兴会;
关键词
D O I
10.1093/rpd/ncad239
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to study the dose reduction effect on occupational exposure of operators and public exposure other than operators when a backscatter shield and a rectangular collimator are used in conjunction with a handheld intraoral X-ray unit. The occupational exposure was reduced to 40% when the backscatter shield was attached to the cone-tip, to 13% when the rectangular collimator was attached and to 7.7% when the backscatter shield and rectangular collimator were used together. On the other hand, the public exposure was reduced to 20% when the rectangular collimator was attached, but the backscatter shield was not effective in reducing the public exposure. Attaching a backscatter shield is effective in reducing the occupational exposure, and a rectangular aperture is effective in reducing the occupational exposure, as well as the public exposure.
引用
收藏
页码:2349 / 2355
页数:7
相关论文
共 50 条
  • [31] Significant Radiation Dose Reduction in the Hybrid Operating Room Using a Novel X-ray Imaging Technology
    van den Haak, R. F. F.
    Hamans, B. C.
    Zuurmond, K.
    Verhoeven, B. A. N.
    Koning, O. H. J.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (04) : 480 - 486
  • [32] Patient Radiation Dose Reduction during Transarterial Chemoembolization Using a Novel X-Ray Imaging Platform
    Kohlbrenner, Ryan
    Kolli, Pallav
    Taylor, Andrew G.
    Kohi, Maureen P.
    Fidelman, Nicholas
    LaBerge, Jeanne M.
    Kerlan, Robert K.
    Agarwal, Vishal K.
    Lehrman, Evan D.
    Nanavati, Sujal
    Avrin, David E.
    Gould, Robert
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (09) : 1331 - 1338
  • [33] Radiation Dose Reduction in Monochromatic Phase Contrast X-Ray Mammography Using Equally Sloped Tomography
    Zhao, Y.
    Brun, E.
    Fahimian, B.
    Bravin, A.
    Sztrokay, A.
    Coan, P.
    Miao, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [34] Reduction in Radiation Dose in a Pediatric Cardiac Catheterization Lab Using the Philips AlluraClarity X-ray System
    Patrick M. Sullivan
    David Harrison
    Sarah Badran
    Cheryl M. Takao
    Frank F. Ing
    Pediatric Cardiology, 2017, 38 : 1583 - 1591
  • [35] Reduction in Radiation Dose in a Pediatric Cardiac Catheterization Lab Using the Philips AlluraClarity X-ray System
    Sullivan, Patrick M.
    Harrison, David
    Badran, Sarah
    Takao, Cheryl M.
    Ing, Frank F.
    PEDIATRIC CARDIOLOGY, 2017, 38 (08) : 1583 - 1591
  • [36] Intraoral Radiology in General Dental Practices - A Comparison of Digital and Film-Based X-Ray Systems with Regard to Radiation Protection and Dose Reduction
    Anissi, H. D.
    Geibel, M. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (08): : 762 - 767
  • [37] STATE PRIMARY STANDARD FOR UNIT OF EXPOSED DOSE OF X-RAY AND GAMMA-RADIATION
    YUDIN, MF
    KOCHINA, MP
    OSTROMUKHOVA, GP
    KONONOVA, RF
    MEASUREMENT TECHNIQUES-USSR, 1972, 15 (02): : 185 - +
  • [38] Radiation field and dose inhomogeneities using an X-ray cabinet in radiation biology research
    Bucher, Martin
    Trinkl, Sebastian
    Endesfelder, David
    Weiss, Tina
    Gomolka, Maria
    Paetzold, Juliane
    Lechel, Ursula
    Roessler, Ute
    Gala, Hugo de Las Heras
    Moertl, Simone
    Giussani, Augusto
    MEDICAL PHYSICS, 2021, 48 (12) : 8140 - 8151
  • [39] Application of the Monte Carlo Method for the Evaluation of Scattered Radiation Dose Due to the Use of Handheld X-Ray in Dentistry
    Gonzales, A. Cc
    Soares, M. R.
    Batista, W. O. G.
    Cardena, A. R.
    Marquez, J. P.
    Vega, J. R.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (16) : 1210 - 1218
  • [40] Generative learning approach for radiation dose reduction in X-ray guided cardiac interventions
    Azizmohammadi, Fariba
    Castellanos, Inaki Navarro
    Miro, Joaquim
    Segars, Paul
    Samei, Ehsan
    Duong, Luc