Effect of Sac Asymmetry, Neck and Iliac Angle on the Hemodynamic Behavior of Idealized Abdominal Aortic Aneurysm Geometries

被引:1
|
作者
Tzirakis, Konstantinos [1 ]
Kontopodis, Nikolaos [2 ,4 ]
Kehagias, Elias [3 ]
Ioannou, Christos, V [2 ]
机构
[1] Hellen Mediterranean Univ, Dept Mech Engn, Iraklion, Crete, Greece
[2] Univ Crete, Med Sch, Vasc Surg Dept, Iraklion, Crete, Greece
[3] Univ Crete, Med Sch, Dept Med Imaging, Intervent Radiol Unit, Iraklion, Crete, Greece
[4] Univ Crete Med Sch, Univ Hosp Heraklion, Dept Cardiothorac & Vasc Surg, Vasc Surg Unit, POB 1352, Iraklion 71110, Greece
关键词
FLUID-STRUCTURE INTERACTION; INTRALUMINAL THROMBUS; SHEAR-STRESS; GROWTH; BIFURCATION; FLOW; DEPOSITION; BLOOD; SIZE;
D O I
10.1016/j.avsg.2023.02.026
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Abdominal aortic aneurysms (AAAs) are currently treated based on the universal maximum diameter criterion, but other geometric variables may play a role in the risk of rupture. The hemodynamic environment inside the AAA sac has been shown to interact with several bio-logic processes which can affect prognosis. AAA geometric configuration has a significant impact in the hemodynamic conditions that develop, which has only been recently realized, with implications for rupture risk estimations. We aim to perform a parametric study to evaluate the effect of aortic neck angulation, angle between the iliac arteries, and sac asymmetry (SA) on the hemodynamic variables of AAAs.Methods: This study uses idealized AAA models and it is parametrized in terms of 3 quantities as follows: the neck angle, f (& DEG;), iliac angle, q (& DEG;), and SA (%), each of which accepts 3 different values, specifically f = (0 & DEG;, 30 & DEG;, 60 & DEG;), q = (40 & DEG;, 60 & DEG;, 80 & DEG;), and SA = (S, & DEG;SS, & DEG;OS), where the SA can either be on the same side with respect to neck (SS) or on the opposite side (OS). Time average wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and the velocity profile are calculated for different geometric configurations, while the percentage of the total surface area under thrombogenic conditions, using thresholds previously reported in the literature, is also recorded.Results: In case of an angulated neck and a higher angle between iliac arteries, favorable he-modynamic conditions are predicted with higher TAWSS and lower OSI and RRT values. The area under thrombogenic conditions reduces by 16-46% as the neck angle increases from 0 & DEG; to 60 & DEG;, depending on the hemodynamic variable under consideration. The effect of iliac angu-lation is present but less pronounced with 2.5-7.5% change between the lower and the higher angle. The effect of SA seems to be significant for OSI, with a nonsymmetrical configuration be-ing hemodynamically favorable, which in the presence of an angulated neck is more pronounced for the OS outline.Conclusions: Favorable hemodynamic conditions develop inside the sac of idealized AAAs with increasing neck and iliac angles. Regarding the SA parameter, asymmetrical configurations most often appear advantageous. Concerning the velocity profile the triplet (f, q, SA) may affect outcomes under certain conditions and thus should be taken into account when parametrizing the geometric characteristics of AAAs.
引用
收藏
页码:338 / 350
页数:13
相关论文
共 48 条
  • [41] Complex EVAR for abdominal aorto-iliac aneurysm (AAIA) is associated with high rate of endoleak and less aortic sac shrinkage compared to conventional EVAR for AAA
    R. Blair
    A. Collins
    D. W. Harkin
    Irish Journal of Medical Science (1971 -), 2015, 184 : 871 - 875
  • [42] Complex EVAR for abdominal aorto-iliac aneurysm (AAIA) is associated with high rate of endoleak and less aortic sac shrinkage compared to conventional EVAR for AAA
    Blair, R.
    Collins, A.
    Harkin, D. W.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2015, 184 (04) : 871 - 875
  • [43] The Effect of Hematocrit and Nanoparticles Diameter on Hemodynamic Parameters and Drug Delivery in Abdominal Aortic Aneurysm with Consideration of Blood Pulsatile Flow
    Jafarzadeh, Sina
    Sadr, Arsalan Nasiri
    Kaffash, Ehsan
    Goudarzi, Sahar
    Golab, Ehsan
    Karimipour, Arash
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 195
  • [44] Feasibility and Safety of Sac Embolization Using N-Butyl Cyanoacrylate in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms or Isolated Iliac Artery Aneurysms
    Ohba, Shota
    Shimohira, Masashi
    Hashizume, Takuya
    Muto, Masahiro
    Ohta, Kengo
    Sawada, Yusuke
    Mizuno, Akihiro
    Nakai, Yosuke
    Suda, Hisao
    Shibamoto, Yuta
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (05) : 828 - 835
  • [45] Impact of Abdominal Aortic Aneurysm Sac Shrinkage on All-cause Survival and Long-term Sac Behavior, up to 5 Years After Endovascular Aortic Repair with a Low-profile Device
    Jorgensen, Isabella K.
    Broda, Magdalena
    Resch, Timothy A.
    Eiberg, Jonas P.
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (06) : E79 - E79
  • [46] Abdominal aortic aneurysm sac behavior following Cook Zenith graft implantation: a five-year follow-up assessment of 212 cases
    Becquemin, J. -P.
    Aksoy, M.
    Marzelle, J.
    Roudot-Thoraval, F.
    Desgranges, P.
    Allaire, E.
    Kobeiter, H.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2008, 49 (02): : 199 - 206
  • [47] Type II Endoleaks After Endovascular Repair of Abdominal Aortic Aneurysms: Fate of the Aneurysm Sac and Neck Changes During Long-term Follow-up
    Nolz, Richard
    Teufelsbauer, Harald
    Asenbaum, Ulrika
    Beitzke, Dietrich
    Funovics, Martin
    Wibmer, Andreas
    Plank, Christina
    Prusa, Alexander M.
    Lammer, Johannes
    Schoder, Maria
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (02) : 193 - 199
  • [48] Computational study on hemodynamic changes in patient-specific proximal neck angulation of abdominal aortic aneurysm with time-varying velocity (vol 42, pg 181, 2019)
    Algabri, Yousif A.
    Rookkapan, Sorracha
    Gramigna, Vera
    Espino, Daniel M.
    Chatpun, Surapong
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (01) : 191 - 191