Microbiological total viable count detection based on tunable diode laser wavelength-modulation spectroscopy

被引:5
|
作者
Wang, Juan [1 ]
Shen, Chenying [1 ]
Lu, Juncheng [1 ]
Yang, Chaofeng [1 ]
Wu, Qiong [1 ]
Chen, Daru [2 ]
Shao, Jie [1 ]
机构
[1] Zhejiang Normal Univ, Key Lab Opt Informat Detect & Display Technol Zhej, Jinhua 321004, Peoples R China
[2] Zhejiang Normal Univ, Hangzhou Inst Adv Studies, Hangzhou 311200, Peoples R China
关键词
Gas sensor; Trace gas detection; Wavelength-modulation spectroscopy; Total viable counts; Microbial detection; ABSORPTION-SPECTROSCOPY; MICROBIAL-GROWTH; CARBON-DIOXIDE; SPECTROMETRY; BIOSENSOR; SENSOR;
D O I
10.1016/j.snb.2023.133332
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Total viable counts (TVC) are vitally critical to health management, and the quantitative testing of TVC is an essential part of the microbiological testing process. This work demonstrates the rapid and accurate measurement of microbiological TVC using a wavelength-modulated tunable diode laser based on absorption spectroscopy (WM-TDLAS). To detect CO2 in sealed culture bottles, a tunable distributed feedback (DFB) laser with a central wavelength of 2004 nm was employed as the light source. Experiments with Salmonella show that the technique can generate effective second harmonic signals, allowing the detection limit to be 71.8 ppm. Simultaneously, the optimal parameters for measuring the growth curve of Salmonella at various concentrations were determined to establish the standard curve used to calculate the TVC. When compared to the conventional method ISO 4833:2013, the new detection method illustrates good correlation (R2 = 0.98), and the results can be obtained within the detection range of 1-8 log10(CFU/mL) in 4-12 h, saving at least 36 h. Thus, it was shown that WM-TDLAS is a user-friendly, non-invasive technique that allows rapid and accurate assessment of TVC.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Wavelength-modulation laser hygrometer for ultrasensitive detection of water vapor in semiconductor gases
    Hovde, DC
    Hodges, JT
    Scace, GE
    Silver, JA
    APPLIED OPTICS, 2001, 40 (06) : 829 - 839
  • [32] Optical humidity detection based on tunable diode laser absorption spectroscopy
    Zhang, Keke
    Liu, Shixuan
    Chen, Shizhe
    Zhao, Qiang
    Zhang, Lijuan
    Li, Xuanqun
    Wang, Wenyan
    Wu, Yushang
    SECOND INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2017, 10256
  • [33] Elimination of residual amplitude modulation in tunable diode laser wavelength modulation spectroscopy using an optical fiber delay line
    Chakraborty, Arup Lal
    Ruxton, Keith
    Johnstone, Walter
    Lengden, Michael
    Duffin, Kevin
    OPTICS EXPRESS, 2009, 17 (12): : 9602 - 9607
  • [34] Measurements of OH radical concentration in combustion environments by wavelength-modulation spectroscopy with a 1.55-μm distributed-feedback diode laser
    Aizawa, Tetsuya
    Kamimoto, Takeyuki
    Tamaru, Takashi
    Applied Optics, 1999, 38 (2-9): : 1733 - 1741
  • [35] Accurate extraction method for the FM response of tunable diode lasers based on wavelength modulation spectroscopy
    J. Chen
    A. Hangauer
    R. Strzoda
    M.-C. Amann
    Applied Physics B, 2008, 90 : 243 - 247
  • [36] Accurate extraction method for the FM response of tunable diode lasers based on wavelength modulation spectroscopy
    Chen, J.
    Hangauer, A.
    Strzoda, R.
    Amann, M. -C.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (02): : 243 - 247
  • [37] Experimental method based on wavelength-modulation spectroscopy for the characterization of semiconductor lasers under direct modulation
    Schilt, S
    Thévenaz, L
    APPLIED OPTICS, 2004, 43 (22) : 4446 - 4453
  • [38] Measurements of OH radical concentration in combustion environments by wavelength-modulation spectroscopy with a 1.55-μm distributed-feedback diode laser
    Aizawa, T
    Kamimoto, T
    Tamaru, T
    APPLIED OPTICS, 1999, 38 (09) : 1733 - 1741
  • [39] Temperature and current coefficients of lasing wavelength in tunable diode laser spectroscopy
    Fukuda, M.
    Mishima, T.
    Nakayama, N.
    Masuda, T.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 100 (02): : 377 - 382
  • [40] Measurements of rubidium in standard reference samples by wavelength-modulation diode laser absorption spectrometry in a graphite furnace
    Ljung, P
    Axner, O
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (03) : 305 - 319