Optimal Placement of Phasor Measurement Unit in Smart Grids Considering Multiple Constraints

被引:1
|
作者
Chen, Tengpeng [1 ,2 ]
Ren, He [1 ]
Sun, Yuhao [3 ]
Kraft, Markus [4 ,5 ,6 ]
Amaratunga, Gehan A. J. [7 ]
机构
[1] Xiamen Univ, Dept Instrumental & Elect Engn, Xiamen, Peoples R China
[2] Shenzhen Res Inst Xiamen Univ, Shenzhen, Peoples R China
[3] CTC Intelligence Shenzhen Technol Co Ltd, Shenzhen, Peoples R China
[4] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge, England
[5] Cambridge Ctr Adv Res & Educ Singapore, CREATE Tower, Singapore, Singapore
[6] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore, Singapore
[7] Univ Cambridge, Dept Engn, Cambridge, England
基金
中国国家自然科学基金; 新加坡国家研究基金会;
关键词
Phasor measurement units; State estimation; Noise measurement; Loss measurement; Power systems; Maximum likelihood estimation; Observability; Phasor measurement unit (PMU); smart grids; optimal placement; state estimation (SE); OPTIMAL PMU PLACEMENT; ROBUST STATE ESTIMATION; CHANNEL CAPACITY; SYSTEM; WAMS; ALGORITHM;
D O I
10.35833/MPCE.2022.000003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The distribution of measurement noise is usually assumed to be Gaussian in the optimal phasor measurement unit (PMU) placement (OPP) problem. However, this is not always accurate in practice. This paper proposes a new OPP method for smart grids in which the effects of conventional measurements, limited channels of PMUs, zero-injection buses (ZIBs), single PMU loss contingency, state estimation error (SEE), and the maximum SEE variance (MSEEV) are considered. The SEE and MSEEV are both obtained using a robust t-distribution maximum likelihood estimator (MLE) because t-distribution is more flexible for modeling both Gaussian and non-Gaussian noises. The A-and G-optimal experimental criteria are utilized to form the SEE and MSEEV constraints. This allows the optimization problem to be converted into a linear objective func- tion subject to linear matrix inequality observability con- straints. The performance of the proposed OPP method is verified by the simulations of the IEEE 14-bus, 30-bus, and 118-bus systems as well as the 211-bus practical distribution system in China.
引用
下载
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
  • [31] Optimal placement of parking of electric vehicles in smart grids, considering their active capacity
    Bai, Yun
    Qian, Qian
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 220
  • [32] Micro Phasor Measurement Unit (μPMU) Placement for Maximum Observability in Smart Distribution Network
    Hampannavar, Santoshkumar
    Deepa, B.
    Swapna, M.
    2021 IEEE PES/IAS POWERAFRICA CONFERENCE, 2021, : 570 - 574
  • [33] A Heuristic Solution Algorithm for a Comprehensive Optimal Phasor Measurement Unit Placement Considering Zero-Injection Buses and Practical Constraints in Power System State Observability Problem
    Hamid Hosseini Dolatabadi, Sayed
    Bhuiyan, Tanveer Hossain
    Golshan, Mohammad Esmail Hamedani
    IEEE ACCESS, 2024, 12 : 79919 - 79936
  • [34] Optimal placement of Phasor Measurement Unit considering System Observability Redundancy Index: case study of the Kenya power transmission network
    Okendo, Edwin Otieno
    Wekesa, Cyrus Wabuge
    Saulo, Michael Juma
    HELIYON, 2021, 7 (07)
  • [35] General optimal substation coverage algorithm for phasor measurement unit placement in practical systems
    Pal, Anamitra
    Mishra, Chetan
    Vullikanti, Anil Kumar S.
    Ravi, S. S.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (02) : 347 - 353
  • [36] A Strategic and Significant Method for the Optimal Placement of Phasor Measurement Unit for Power System Network
    Baba, Maveeya
    Nor, Nursyarizal B. M.
    Sheikh, M. Aman
    Irfan, Muhammad
    Tahir, Mohammad
    SYMMETRY-BASEL, 2020, 12 (07):
  • [37] Phasor Measurement Unit Integration: A Review on Optimal PMU Placement Methods in Power System
    Noureen, Subrina Sultana
    Roy, Vishwajit
    Bayne, Stephen B.
    2017 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2017, : 328 - 332
  • [38] Phasor measurement unit placement based on incomplete observability
    Nuqui, RF
    Phadke, AG
    2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2002, : 888 - 893
  • [39] Optimal PMU Placement for Identification of Multiple Power Line Outages in Smart Grids
    Wu, Jie
    Xiong, Jinjun
    Shil, Prasenjit
    Shi, Yiyu
    2014 IEEE 57TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2014, : 354 - 357
  • [40] An Approach for Optimal Placement of Phasor Measurement Units considering Fuzzy logic based Critical Buses
    Rokkam, Venkatesh
    Bhimasingu, Ravikumar
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART ENERGY GRID ENGINEERING (SEGE), 2013,