A hybrid machine learning-assisted optimization and rule-based energy monitoring of a green concept based on low-temperature heating and high-temperature cooling system

被引:11
|
作者
Behzadi, Amirmohammad [1 ]
Gram, Annika [1 ]
Thorin, Eva [2 ]
Sadrizadeh, Sasan [1 ,2 ]
机构
[1] KTH Royal Inst Technol, Dept Civil & Architectural Engn, Stockholm, Sweden
[2] Malardalen Univ, Sch Business Soc & Engn, Vasteras, Sweden
关键词
Low-temperature heating; Multi-objective optimization; Heat pump; High-temperature cooling; Geothermal; Smart energy system; PERFORMANCE; EFFICIENCY; BUILDINGS; STORAGE;
D O I
10.1016/j.jclepro.2022.135535
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article aims to support the targeted worldwide green transition process by introducing and thoroughly analyzing a low-temperature heating and high-temperature cooling, smart building system. This concept allows for greater use of renewable energy while utilizing less input energy than conventional heating and cooling techniques. The proposed system consists of a reversible water-to-water heat pump driven by low-temperature geothermal energy. A rule-based control strategy is developed to establish an intelligent connection with the regional energy grids for peak shaving and compensating for the building's energy costs over the year. The dynamic simulation is carried out for a multi-family building complex in Stockholm, Sweden, using TRNSYS. The most favorable operating condition is determined via an artificial neural network-assisted tri-objective optimizer based on the grey wolf algorithm in MATLAB. The comparison of the proposed smart model with the conven-tional system in Sweden results in 332%, 203%, and 190% primary energy reduction, cost saving, and carbon dioxide emission mitigation, respectively. As indicated by the parametric results, the conflicting fluctuation between desirable and unfavorable indicators highlights the importance of multi-objective optimization. The grey wolf optimizer obtains 12% higher efficiency, 1.2 MWh lower annual bought energy, 24 $/MWh lower unit cost, and 5.1 MWh more yearly sold energy than the design condition. The scattered distribution reveals that tank volume and subcooling degree are sensitive parameters. According to the transient results, the suggested smart system can independently satisfy the building's heating, cooling, and electricity demands for more than 81% of the year, thanks to the two-way connection with the electricity and heating networks via the rule-based controller.
引用
收藏
页数:15
相关论文
共 22 条
  • [21] Low-Temperature NO2 Gas-Sensing System Based on Metal-Organic Framework-Derived In2O3 Structures and Advanced Machine Learning Techniques
    Amu-Darko, Jesse Nii Okai
    Hussain, Shahid
    Agyekum, Enock Adjei
    Begi, Amensisa Negasa
    Shah, Sufaid
    Yusuf, Kareem
    Manavalan, Rajesh Kumar
    Qiao, Guanjun
    Liu, Guiwu
    INORGANIC CHEMISTRY, 2024, 63 (35) : 16429 - 16441
  • [22] Investigation of a green energy storage system based on liquid air energy storage (LAES) and high-temperature concentrated solar power (CSP): Energy, exergy, economic, and environmental (4E) assessments, along with a case study for San Diego, US
    Nabat, Mohammad Hossein
    Soltani, M.
    Razmi, Amir Reza
    Nathwani, Jatin
    Dusseault, M. B.
    SUSTAINABLE CITIES AND SOCIETY, 2021, 75 (75)