Removal of Cd(II), Co(II), Cr(III), Ni(II), Pb(II) and Zn(II) ions from wastewater using polyethyleneimine (PEI) cryogels

被引:18
|
作者
Bagdat, Sema [1 ]
Tokay, Feyzullah [1 ,2 ]
Demirci, Sahin [2 ,3 ]
Yilmaz, Selehattin [2 ]
Sahiner, Nurettin [2 ,3 ,4 ]
机构
[1] Balikesir Univ, Fac Sci, Chem Dept, TR-10145 Balikesir, Turkiye
[2] Canakkale Onsekiz Mart Univ, Fac Sci, Dept Chem, Terzioglu Campus, TR-17100 Canakkale, Turkiye
[3] Canakkale Onsekiz Mart Univ, Nanosci & Technol Res & Applicat Ctr, Terzioglu Campus, TR-17100 Canakkale, Turkiye
[4] Univ S Florida, Dept Chem & Biomol Engn, Tampa, FL 33620 USA
关键词
Cryogel; Macro porous adsorbent; Heavy metal ion removal; Adsorption; Wastewater treatment; POLY(VINYL ALCOHOL)/HYDROXYAPATITE CRYOGELS; CADMIUM SORPTION PROPERTIES; ADSORBENTS; PERFORMANCE; ADSORPTION; ACID;
D O I
10.1016/j.jenvman.2022.117002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The removal of the target analytes, Cd(II), Co(II), Cr(III), Ni(II), Pb(II), and Zn(II) from contaminated waters was achieved using super porous polyethyleneimine (PEI) cryogels as adsorbent. The optimum values of the sample pH and contact time were determined as 4.0 and 90 min, respectively, for the removal of the analytes. The adsorption capacities of the sorbent were between 19.88 and 24.39 mgg- 1 from 10 mL of 50 mgL-1 target metal ion solutions. The sorption kinetics of metal ions were fitted with the pseudo-second-order model. The adsorption isotherms of the target analytes into PEI cryogel were well-fitted to the Langmuir isotherm model as expected from the material homogeneity. The selectivity of the PEI cryogel in the presence of Na+, Ca2+, Mg2+, NO3-, K+ and Cl- ions even at high concentrations was tested, and the tolerance limits were satisfactory enough, e.g., the adsorption of the target analytes was even not affected in the presence of 2000 mgL-1 Ca2+, K+, Na+, Cl- and 5000 mgL-1 NO3- ions. The PEI cryogels were successfully utilized in different industrial wastewater samples that were spiked with a known amount of analytes. The removal of the analytes from wastewater samples was in the following ranges 91.94-99.86% for Cd(II), 89.59-99.89% for Co(II), 80.35-99.76% for Cr(III), 92.02-99.84% for Ni(II), 83.28-99.86% for Pb(II), and 82.94-98.24% for Zn(II), respectively. The presented novel removal strategy offers a selective, efficient, and easy application for target metal ions from industrial wastewater samples.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [41] The behavior of Ni(II), Cr(III), and Zn(II) in biological wastewater treatment process
    Ong, SA
    Toorisaka, E
    Hirata, M
    Hano, T
    ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 2005, 33 (02): : 95 - 103
  • [42] Removal of Pb (II), Zn (II) and Cd (II) from Hydrometallurgical Effluent by Ferrite Formation
    Li Dou
    Li Dongwei
    RESEARCH JOURNAL OF CHEMISTRY AND ENVIRONMENT, 2010, 14 (02): : 83 - 87
  • [43] MXene/chitosan/lignosulfonate (MCL) nanocomposite for simultaneous removal of Co(II), Cr(VI), Cu(II), Ni(II) and Pb(II) heavy metals from wastewater
    Othman, Zakarya
    Mackey, Hamish R.
    Mahmoud, Khaled A.
    2D MATERIALS, 2023, 10 (02)
  • [44] REMOVAL OF Cu (II), Ni (II), Cd (II) AND Cr (VI) IONS FROM AQUEOUS SOLUTIONS BY BIOSORPTION PROCESSES
    Aslan, Seda
    Bozkurt, Zehra
    Tekeli, Ayca N.
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2007, 25 (02): : 209 - 222
  • [45] PHYSICOCHEMICAL STUDIES OF NI(II), CO(II), ZN(II) AND CD(II) IONS-PARA-BROMOBENZOYLACETONATE SYSTEMS
    GUPTA, BP
    RAI, AK
    BACHLAS, BP
    JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1976, 38 (06): : 1163 - 1165
  • [46] MN(II), CO(II), NI(II), CU(II), ZN(II) AND CD(II) COMPLEXES OF ACRYLAMIDE
    SAMANTARAY, A
    PANDA, PK
    MOHAPATRA, BK
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1980, 57 (04) : 430 - 432
  • [47] Batch removal of Cd(II), Cu(II), Ni(II), and Pb(II) ions using stabilized zero-valent iron nanoparticles
    Danila, Vaidotas
    Vasarevicius, Saulius
    Valskys, Vaidotas
    INTERNATIONAL SCIENTIFIC CONFERENCE ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, CONECT 2018, 2018, 147 : 214 - 219
  • [48] Modeling the adsorption of Cd (II), Cu (II), Ni (II), Pb (II) and Zn (II) onto montmorillonite
    Gu, Xueyuan
    Evans, Les J.
    Barabash, Sarah J.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2010, 74 (20) : 5718 - 5728
  • [49] Tartrazine modified activated carbon for the removal of Pb(II), Cd(II) and Cr(III)
    Monser, Lotfi
    Adhoum, Nafaa
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 161 (01) : 263 - 269
  • [50] THERMAL-DECOMPOSITION OF CO(II), NI(II), CU(II), ZN(II), CD(II) AND PB(II) HYDROXY-P-TOLUENESULPHONATES
    BOMBIN, M
    MARTINEZZAPORTA, MA
    RAMIREZ, A
    GUERRERO, A
    MENDEZ, AJ
    THERMOCHIMICA ACTA, 1993, 224 : 151 - 163