Corrosion detection of reinforced concrete structures based on microwave nondestructive technique

被引:4
|
作者
Li, Peng [1 ,2 ]
Yu, Honglin [1 ,2 ]
Li, Zijin [1 ,2 ]
Zhang, Boming [1 ,2 ]
Wu, Tian [1 ,2 ]
Pu, Ziheng [1 ,2 ]
Wang, Shenhua [3 ]
机构
[1] China Three Gorges Univ, Hubei Prov Engn Technol Res Ctr Power Transmiss Li, Yichang 443002, Peoples R China
[2] China Three Gorges Univ, Coll Elect Engn & New Energy, Yichang 443002, Peoples R China
[3] State Grid Zhejiang Wuyi Elect Power Supply Co, Jinhua 321200, Peoples R China
关键词
STEEL BARS; DEFECTS;
D O I
10.1063/5.0141223
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The corrosion of rebars will change the mechanical properties of the reinforced concrete structure, leading to the decline in the structural strength, which seriously threatens the safety and stability of buildings and power equipment foundations. Hence, it is of great significance to detect the internal corrosion of reinforced concrete structures. In this paper, a nondestructive detection method for detecting the corrosion in reinforced concrete structures based on microwave was proposed, and the corrosion state of rebar can be evaluated by the change of microwave information. Compared with other detection methods, microwave nondestructive detection has the advantages of low energy consumption, strong penetration, no contact, and small equipment volume and weight. In order to verify the effectiveness of the method, a microwave nondestructive detection simulation test platform was built and reinforced concrete test models with different corrosion lengths and depths were made. The influences of concrete parameters, the microwave frequency, and the lifting distance of the waveguide were analyzed. The frequency sweeping and moving scanning detection methods of the waveguide were carried out for the test models with different corrosion defects, and the changes of microwave S-parameters under different corrosion defects were obtained. The results show that when the waveguide is placed horizontally by the frequency sweeping detection method, the corrosion length detection effect of rebar is better. When the waveguide is placed vertically by the frequency sweeping detection method, the corrosion depth can be identified and the amplitude of transmission coefficient increases with the increase in the corrosion depth. The corrosion length of rebars can be identified quantitatively by the moving scanning detection method of the waveguide.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Formulation of a Nondestructive Technique for Evaluating Steel Corrosion in Concrete Structures
    Lim, Young-Chul
    Noguchi, Takafumi
    Shin, Sung-Woo
    ISIJ INTERNATIONAL, 2009, 49 (02) : 275 - 283
  • [2] A Damage Detection Technique for Reinforced Concrete Structures
    Wu, Ai-Lun
    Yang, Jann N.
    Loh, Chin-Hsiung
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2012, PTS 1 AND 2, 2012, 8345
  • [3] Nondestructive inspection of reinforced concrete structures
    Miller, Tri Huu
    Yanagita, Tamaki
    Kundu, Tribikram
    Grill, Julian
    Grill, Wolfgang
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2009, 2009, 7295
  • [4] Analysis of the Electromagnetic Signature of Reinforced Concrete Structures for Nondestructive Evaluation of Corrosion Damage
    Roqueta, Gemma
    Jofre, Lluis
    Feng, Maria Q.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (04) : 1090 - 1098
  • [5] Corrosion detection on reinforced concrete structures: conventional and innovative
    Kessler, Sylvia
    Emmenegger, Leonidas P.
    Sagues, Alberto A.
    BAUTECHNIK, 2020, 97 (01) : 11 - 20
  • [6] Nondestructive evaluation of air voids in concrete structures using microwave radar technique
    Takayama J.-Y.
    Ohara Y.
    Sun W.
    SICE Journal of Control, Measurement, and System Integration, 2022, 15 (01) : 36 - 47
  • [8] Inspection of Steel Bars Corrosion in Reinforced Concrete Structures by Nondestructive Ground Penetrating Radar
    Chang, Che-Way
    Tsai, Che-An
    Shiau, Yan-Chyuan
    APPLIED SCIENCES-BASEL, 2022, 12 (11):
  • [9] A nonlinear acoustic technique for crack and corrosion detection in reinforced concrete
    Donskoy, DM
    Ferroni, K
    Sutin, A
    Sheppard, K
    NONDESTRUCTIVE CHARACTERIZATION OF MATERIALS VIII, 1998, : 555 - 560
  • [10] ON-SITE DETECTION OF CORROSION IN REINFORCED-CONCRETE STRUCTURES
    GONZALEZ, JA
    FELIU, S
    ANDRADE, C
    RODRIGUEZ, I
    MATERIALS AND STRUCTURES, 1991, 24 (143): : 346 - 350