ON-SITE DETECTION OF CORROSION IN REINFORCED-CONCRETE STRUCTURES

被引:13
|
作者
GONZALEZ, JA [1 ]
FELIU, S [1 ]
ANDRADE, C [1 ]
RODRIGUEZ, I [1 ]
机构
[1] INST EDUARDO TORROJA CONSTRUCT & CEMENT,CSIC,E-28033 MADRID,SPAIN
来源
MATERIALS AND STRUCTURES | 1991年 / 24卷 / 143期
关键词
D O I
10.1007/BF02472067
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The availability of on-site methods of diagnosis of the deterioration rate in reinforced concrete structures is a pressing technical need all over the world. Two new methods are proposed in this paper which are derived from the polarization resistance method, but which, differing from this method, are applicable to full-size structures, in spite of the non-uniform distribution of the electric signals in them. The two proposed procedures are of a simplicity and reliability comparable with those offered by direct measurement of polarization resistance.
引用
收藏
页码:346 / 350
页数:5