How to establish and use local diagnostic reference levels: an ESR EuroSafe Imaging expert statement

被引:17
|
作者
Damilakis, John [1 ]
Frija, Guy [2 ]
Brkljacic, Boris [3 ]
Vano, Eliseo [4 ]
Loose, Reinhard [5 ]
Paulo, Graciano [6 ]
Brat, Hugues [7 ]
Tsapaki, Virginia [8 ]
机构
[1] Univ Crete, Sch Med, Iraklion, Crete, Greece
[2] Univ Paris, 12 Rue Ecole Med, F-75006 Paris, France
[3] Univ Zagreb, Sch Med, Salata 3, Zagreb 10000, Croatia
[4] Univ Complutense Madrid, Madrid, Spain
[5] Hosp Nuremberg, Inst Med Phys, Prof Ernst Nathan Str 1, D-90419 Nurnberg, Germany
[6] Inst Politecn Coimbra, ESTESC Coimbra Hlth Sch, Med Imaging & Radiotherapy Dept, Rua 5 Outubro, P-3046854 Coimbra, Portugal
[7] Inst Radiol Sion, Rue Scex 2, CH-1950 Sion, Switzerland
[8] Konstantopoulio Gen Hosp, Med Phys, Nea Ionia, Greece
[9] European Soc Radiol ESR, Gestade 1, A-1010 Vienna, Austria
关键词
Diagnostic reference levels; Optimisation; Radiation dosage;
D O I
10.1186/s13244-023-01369-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although the Diagnostic Reference Levels (DRLs) have been shown to be an important tool for optimising patient radiation protection, there are still difficulties related to the methodology that should be used to establish and use local DRL values. This statement represents the current view of the EuroSafe Imaging 'Clinical DRLs' working group formed with the purpose to produce scientific and educational material on DRLs and promote the concept of local DRLs. Guidelines on how to establish and how to use local DRLs presented herein can be implemented using a multidisciplinary team approach. Local DRLs are easy to determine and implement and they reflect local equipment performance and local clinical needs. They can be updated more frequently than the national DRLs, especially if a dose management system is available. To establish local DRLs, a practical approach could be to collect a reasonable set, i.e., at least 20-30 procedures, of data for well-defined clinical indications and calculate the 3rd quartile values. The median values of the distribution can be set to define the 'typical values'. The International Commission of Radiological Protection (ICRP) suggests setting 'typical values' for newer technologies that enable decreased amounts of radiation exposure for a similar level of image quality. Local DRLs should be similar or lower to the national DRLs. They could be higher only if the clinical benefits for some medical indications are fully explained and reported. Local DRLs may be used as a quality benchmark to track outliers and can be also used as alert values.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Local diagnostic reference levels for intraoral dental radiography in the public hospitals of Cyprus
    Christofides, Stelios
    Pitri, Elina
    Lampaskis, Marios
    Papaefstathiou, Christos
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1437 - 1443
  • [42] Implementation of Size-Dependent Local Diagnostic Reference Levels for CT Angiography
    Boere, Hub
    Eijsvoogel, Nienke G.
    Sailer, Anna M.
    Wildberger, Joachim E.
    de Haan, Michiel W.
    Das, Marco
    Jeukens, Cecile R. L. P. N.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : W226 - W233
  • [43] Use of TLD in evaluating diagnostic reference levels for some radiological examinations
    Berni, D
    Gori, C
    Lazzari, B
    Mazzocchi, S
    Rossi, F
    Zatelli, G
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 411 - 413
  • [44] Use of TLD in evaluating diagnostic reference levels for some radiological examinations
    Berni, D
    Gori, C
    Lazzari, B
    Mazzocchi, S
    Rossi, F
    Zatelli, G
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A411 - A413
  • [45] Adult reference levels in diagnostic and interventional radiology for temporary use in Switzerland
    Aroua, A
    Besançon, A
    Buchillier-Decka, I
    Trueb, P
    Valley, JF
    Verdun, FR
    Zeller, W
    RADIATION PROTECTION DOSIMETRY, 2004, 111 (03) : 289 - 295
  • [46] Local diagnostic reference levels in diagnostic and therapeutic pediatric cardiology at a specialist pediatric hospital in South Africa
    Mbewe, Jonathan
    Mjenxane, Thembisa
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (04): : 180 - 187
  • [47] THE APPLICATION OF DIAGNOSTIC REFERENCE LEVELS FOR OPTIMISATION OF X-RAY IMAGING IN THE UK
    Martin, Colin J.
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 211 - 216
  • [48] Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels
    Crawley, MT
    Rogers, AT
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (871): : 740 - 744
  • [49] A British Society of Thoracic Imaging statement: considerations in designing local imaging diagnostic algorithms for the COVID-19 pandemic
    Nair, A.
    Rodrigues, J. C. L.
    Hare, S.
    Edey, A.
    Devaraj, A.
    Jacob, J.
    Johnstone, A.
    McStay, R.
    Denton, Erika
    Robinson, G.
    CLINICAL RADIOLOGY, 2020, 75 (05) : 329 - 334
  • [50] ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR TYPICAL RADIOGRAPHY EXAMINATIONS IN THE WEST REGION OF CROATIA
    Segota, Doris
    Diklic, Ana
    Jurkovic, Slaven
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2019, 34 (01): : 102 - 106