A compendium of single extracellular vesicle flow cytometry

被引:57
|
作者
Welsh, Joshua A. [1 ]
Arkesteijn, Ger J. A. [2 ]
Bremer, Michel [3 ]
Cimorelli, Michael [5 ,6 ]
Dignat-George, Francoise [7 ,8 ]
Giebel, Bernd [3 ]
Goergens, Andre [3 ,9 ,10 ]
Hendrix, An [11 ]
Kuiper, Martine [5 ,12 ,13 ]
Lacroix, Romaric [7 ,8 ]
Lannigan, Joanne [14 ]
van Leeuwen, Ton G. [4 ,12 ,15 ,16 ]
Lozano-Andres, Estefania [2 ]
Rao, Shoaib [3 ]
Robert, Stephane [7 ,8 ]
de Rond, Leonie [5 ]
Tang, Vera A. [17 ]
Tertel, Tobias [3 ]
Yan, Xiaomei [18 ]
Wauben, Marca H. M. [2 ]
Nolan, John P. [19 ,20 ]
Jones, Jennifer C. [1 ]
Nieuwland, Rienk [4 ,5 ,15 ]
van der Pol, Edwin [4 ,5 ,15 ]
机构
[1] NCI, Translat Nanobiol Sect, Lab Pathol, Ctr Canc Res,NIH, Bethesda, MD 20892 USA
[2] Univ Utrecht, Fac Vet Med, Dept Biomol Hlth Sci, Utrecht, Netherlands
[3] Univ Duisburg Essen, Univ Hosp Essen, Inst Transfus Med, Essen, Germany
[4] Univ Amsterdam, Med Ctr, Vesicle Observat Ctr, Amsterdam, Netherlands
[5] Univ Amsterdam, Med Ctr, Expt Clin Chem, Amsterdam, Netherlands
[6] Drexel Univ, Dept Chem Engn, Philadelphia, PA USA
[7] Aix Marseille Univ, INSERM, INRAE, C2VN,UFR Pharm, Marseille, France
[8] Assistance Publ Hop Marseille, CHU Concept, Hematol & Vasc Biol Dept, Marseille, France
[9] Karolinska Inst, Clin Res Ctr, Dept Lab Med, Stockholm, Sweden
[10] Evox Therapeut Ltd, Oxford, England
[11] Univ Ghent, Dept Human Struct & Repair, Lab Expt Canc Res, Ghent, Belgium
[12] Univ Amsterdam, Med Ctr, Biomed Engn & Phys, Amsterdam, Netherlands
[13] VSL, Dutch Metrol Inst, Delft, Netherlands
[14] Flow Cytometry Support Serv LLC, Arlington, VA USA
[15] Atherosclerosis & Ischem Syndromes, Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[16] Canc Ctr Amsterdam, Imaging & Biomarkers, Amsterdam, Netherlands
[17] Univ Ottawa, Fac Med, Dept Biochem Microbiol & Immunol, Flow Cytometry & Virometry Core Facil, Ottawa, ON, Canada
[18] Xiamen Univ, Coll Chem & Chem Engn, Dept Chem Biol, MOE Key Lab Spectrochem Anal & Instrumentat,Key L, Xiamen, Fujian, Peoples R China
[19] Scintillon Inst, San Diego, CA 92121 USA
[20] Cellarcus Biosci, San Diego, CA USA
基金
美国国家科学基金会; 中国国家自然科学基金; 美国国家卫生研究院;
关键词
calibration; extracellular vesicles; flow cytometry; microparticles; MIFlowCyt-EV; nanoparticles; standardization; SEMICONDUCTING POLYMER DOTS; CELL-DERIVED MICROPARTICLES; REFRACTIVE-INDEX; FLUORESCENCE LIFETIME; MEMBRANE-PROTEINS; BILAYER THICKNESS; LIGHT-SCATTERING; RESOLUTION; SIZE; MICROVESICLES;
D O I
10.1002/jev2.12299
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Flow cytometry (FCM) offers a multiparametric technology capable of characterizing single extracellular vesicles (EVs). However, most flow cytometers are designed to detect cells, which are larger than EVs. Whereas cells exceed the background noise, signals originating from EVs partly overlap with the background noise, thereby making EVs more difficult to detect than cells. This technical mismatch together with complexity of EV-containing fluids causes limitations and challenges with conducting, interpreting and reproducing EV FCM experiments. To address and overcome these challenges, researchers from the International Society for Extracellular Vesicles (ISEV), International Society for Advancement of Cytometry (ISAC), and the International Society on Thrombosis and Haemostasis (ISTH) joined forces and initiated the EV FCM working group.To improve the interpretation, reporting, and reproducibility of future EV FCM data, the EV FCM working group published an ISEV position manuscript outlining a framework of minimum information that should be reported about an FCM experiment on single EVs (MIFlowCyt-EV). However, the framework contains limited background information. Therefore, the goal of this compendium is to provide the background information necessary to design and conduct reproducible EV FCM experiments. This compendium contains background information on EVs, the interaction between light and EVs, FCM hardware, experimental design and preanalytical procedures, sample preparation, assay controls, instrument data acquisition and calibration, EV characterization, and data reporting. Although this compendium focuses on EVs, many concepts and explanations could also be applied to FCM detection of other particles within the EV size range, such as bacteria, lipoprotein particles, milk fat globules, and viruses.
引用
收藏
页数:70
相关论文
共 50 条
  • [41] Kinetics and Specificity of HEK293T Extracellular Vesicle Uptake using Imaging Flow Cytometry
    Brian J. Jurgielewicz
    Yao Yao
    Steven L. Stice
    Nanoscale Research Letters, 15
  • [42] Quantitative flow cytometry enables end-to-end optimization of cross-platform extracellular vesicle studies
    Cook, Sean
    Tang, Vera A.
    Lannigan, Joanne
    Jones, Jennifer C.
    Welsh, Joshua A.
    CELL REPORTS METHODS, 2023, 3 (12):
  • [43] Imaging flow cytometry challenges the usefulness of classically used extracellular vesicle labeling dyes and qualifies the novel dye Exoria for the labeling of mesenchymal stromal cell-extracellular vesicle preparations
    Tertel, Tobias
    Schoppet, Melanie
    Stambouli, Oumaima
    Al-Jipouri, Ali
    James, Patrick F.
    Giebel, Bernd
    CYTOTHERAPY, 2022, 24 (06) : 619 - 628
  • [44] Influence of extracellular calcium on single platelet activation as measured by whole blood flow cytometry
    Hu, H
    Forslund, M
    Li, NL
    THROMBOSIS RESEARCH, 2005, 116 (03) : 241 - 247
  • [45] Single-Particle Discrimination of Retroviruses from Extracellular Vesicles by Nanoscale Flow Cytometry
    Tang, Vera A.
    Renner, Tyler M.
    Fritzsche, Anna K.
    Burger, Dylan
    Langlois, Marc-Andre
    SCIENTIFIC REPORTS, 2017, 7
  • [46] DEVELOPMENT OF A SPECTRAL FLOW CYTOMETRY APPROACH FOR DIAGNOSTIC PROFILING OF SINGLE URINARY EXTRACELLULAR VESICLES
    Ng, Monica Suet Ying
    Giuliani, Kurt T. K.
    Wang, Xiangju
    Kassianos, Andrew J.
    Healy, Helen G.
    NEPHROLOGY, 2022, 27 : 68 - 69
  • [47] Single-Particle Discrimination of Retroviruses from Extracellular Vesicles by Nanoscale Flow Cytometry
    Vera A. Tang
    Tyler M. Renner
    Anna K. Fritzsche
    Dylan Burger
    Marc-André Langlois
    Scientific Reports, 7
  • [48] Isolation-free measurement of single urinary extracellular vesicles by imaging flow cytometry
    Wu, Liang
    Woud, Wouter W.
    Baan, Carla C.
    Hesselink, Dennis A.
    van der Pol, Edwin
    Jenster, Guido
    Boer, Karin
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2023, 48
  • [49] Systematic Methodological Evaluation of a Multiplex Bead-Based Flow Cytometry Assay for Detection of Extracellular Vesicle Surface Signatures
    Wiklander, Oscar P. B.
    Bostancioglu, R. Beklem
    Welsh, Joshua A.
    Zickler, Antje M.
    Murke, Florian
    Corso, Giulia
    Felldin, Ulrika
    Hagey, Daniel W.
    Evertsson, Bjorn
    Liang, Xiu-Ming
    Gustafsson, Manuela O.
    Mohammad, Dara K.
    Wiek, Constanze
    Hanenberg, Helmut
    Bremer, Michel
    Gupta, Dhanu
    Bjornstedt, Mikael
    Giebel, Bernd
    Nordin, Joel Z.
    Jones, Jennifer C.
    EL Andaloussi, Samir
    Goergens, Andre
    FRONTIERS IN IMMUNOLOGY, 2018, 9
  • [50] Application of Single Extracellular Vesicle Analysis Techniques
    Zhu, Junquan
    Wu, Feifeng
    Li, Cuifang
    Mao, Jueyi
    Wang, Yang
    Zhou, Xin
    Xie, Haotian
    Wen, Chuan
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2023, 18 : 5365 - 5376