The relationship between geometry and hemodynamics of the stenotic carotid artery based on computational fluid dynamics

被引:4
|
作者
Liu, Yongsheng [1 ]
Jiang, Guinan [1 ]
Wang, Xuwen [1 ]
An, Xiangbo [1 ]
Wang, Feng [1 ,2 ]
机构
[1] Dalian Med Univ, Dept Pathol, Affiliated Hosp 1, Dalian, Peoples R China
[2] 222 Zhongshan Rd, Dalian, Peoples R China
关键词
Carotid artery; Computational fluid dynamics; Geometry; Hemodynamics; Stenosis; WALL SHEAR-STRESS; FRACTIONAL FLOW RESERVE; PATIENT; ASSOCIATION; STROKE; ATHEROSCLEROSIS; VULNERABILITY; PREDICTION; PARAMETER; PRESSURE;
D O I
10.1016/j.clineuro.2023.107860
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: The purpose of this work was to investigate the relationship between the geometric factors and the hemodynamics of the stenotic carotid artery.ethods: We retrospectively reviewed data of patients with carotid stenosis (40%-95%). The Navier-Stokes equations were solved using ANSYS CFX 18.0. Correlation analysis was based on Spearman's test. Geometric variables (p < 0.1 in the univariate analysis) were entered into the logistical regression. A receiver-operating characteristics analysis was used to detect hemodynamically significant lesions. Results: 81 patients (96 arteries) were evaluated. The logistic regression analysis revealed that the translesional pressure ratio was significantly correlated with the stenosis degree (OR = 1.147, p < 0.001) and the angle between internal carotid artery and external carotid artery (angle ?) (OR = 0.933, p = 0.01). The translesional wall shear stress ratio was significantly correlated with stenosis degree (OR = 1.094, p < 0.001), lesion length (OR = 0.873, p = 0.01), lumen area of internal carotid artery (OR = 0.867, p = 0.002), and lumen area of common carotid artery (OR = 1.058, p = 0.01). For predicting low translesional pressure ratio, the AUC was 0.71 (p < 0.001) for angle ?, and was 0.87 (p < 0.001) for stenosis degree. For predicting high translesional wall shear stress ratio, the AUC was 0.62 (p = 0.04) for lumen area of internal carotid artery, and was 0.77 (p < 0.001) for stenosis degree.Conclusions: Apart from stenosis degree, other geometric characteristics of lesions may also have an influence on hemodynamics of the stenotic carotid artery.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Aneurysm flow characteristics in realistic carotid artery aneurysm models induced by proximal virtual stenotic plaques: A computational hemodynamics study
    Castro, Marcelo A.
    Peloc, Nora L.
    Chien, Aichi
    Goldberg, Ezequiel
    Putman, Christopher M.
    Cebral, Juan R.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [22] High-Frequency Fluctuations in Post-stenotic Patient Specific Carotid Stenosis Fluid Dynamics: A Computational Fluid Dynamics Strategy Study
    Mancini, Viviana
    Bergersen, Aslak W.
    Vierendeels, Jan
    Segers, Patrick
    Valen-Sendstad, Kristian
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2019, 10 (02) : 277 - 298
  • [23] High-Frequency Fluctuations in Post-stenotic Patient Specific Carotid Stenosis Fluid Dynamics: A Computational Fluid Dynamics Strategy Study
    Viviana Mancini
    Aslak W. Bergersen
    Jan Vierendeels
    Patrick Segers
    Kristian Valen-Sendstad
    Cardiovascular Engineering and Technology, 2019, 10 : 277 - 298
  • [24] Analysis of haemodynamic disturbance in the atherosclerotic carotid artery using computational fluid dynamics
    Birchall, D
    Zaman, A
    Hacker, J
    Davies, G
    Mendelow, D
    EUROPEAN RADIOLOGY, 2006, 16 (05) : 1074 - 1083
  • [25] Analysis of haemodynamic disturbance in the atherosclerotic carotid artery using computational fluid dynamics
    Daniel Birchall
    Azfar Zaman
    Jacob Hacker
    Gavin Davies
    David Mendelow
    European Radiology, 2006, 16 : 1074 - 1083
  • [26] Numerical Study on Relationship between Geometric Features of Stenotic Lesion and Hemodynamics-based Diagnostic Indices of Coronary Artery Disease
    Duc Minh Tran
    Viet Khai Nguyen
    Minh Tuan Nguyen
    Lee, Sang-Wook
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2018, 42 (07) : 479 - 485
  • [27] Computational Fluid Dynamics to Evaluate the Management of a Giant Internal Carotid Artery Aneurysm
    Russin, Jonathan
    Babiker, Haithem
    Ryan, Justin
    Rangel-Castilla, Leonardo
    Frakes, David
    Nakaji, Peter
    WORLD NEUROSURGERY, 2015, 83 (06) : 1057 - 1065
  • [28] Influences of Vascular Geometry and Blood Property on Carotid Artery Hemodynamics
    Prakobkarn, Arpapan
    Chatpun, Surapong
    Saeheng, Sakchai
    Ina, Natee
    Chantarapanich, Nattapon
    6TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2013), 2013,
  • [29] Carotid Geometry as a Predictor of In-Stent Neointimal Hyperplasia - A Computational Fluid Dynamics Study -
    Yao, Xinke
    Dai, Zhengze
    Zhang, Xu
    Gao, Jie
    Xu, Gelin
    Cai, Yan
    Li, Zhiyong
    CIRCULATION JOURNAL, 2019, 83 (07) : 1472 - +
  • [30] Computational fluid dynamics analysis of tandem carotid artery stenoses: Investigation of neurological complications after carotid artery stenting
    Kambayashi, Yukinao
    Takao, Hiroyuki
    Shinohara, Kouichi
    Suzuki, Takashi
    Takayama, Sho
    Fujimura, Soichiro
    Masuda, Shunsuke
    Watanabe, Mituyoshi
    Suzuki, Tomoaki
    Dahmani, Chihebeddine
    Ishibashi, Toshihiro
    Yamamoto, Makoto
    Murayama, Yuichi
    TECHNOLOGY AND HEALTH CARE, 2016, 24 (05) : 673 - 679