Full-scale experimental and structural characterization study of shield tunnel reinforcement under ground stacking loads

被引:0
|
作者
Wei, Gang [1 ,2 ,3 ,8 ]
Zhou, Xinxin [5 ]
Xu, Tianbao [4 ]
Zhang, Yong [6 ]
Yao, Zewei [6 ]
Feng, Shi [7 ]
机构
[1] Hangzhou City Univ, Dept Civil Engn, Hangzhou 310015, Peoples R China
[2] Key Lab Safe Construction & Intelligent Maintenanc, Hangzhou 310015, Peoples R China
[3] Zhejiang Engn Res Ctr intelligent urban infrastruc, Hangzhou 310015, Peoples R China
[4] Anhui Univ Sci & Technol, Sch Civil Engn & Architecture, Huainan 232001, Peoples R China
[5] Zhejiang Univ, Coll Civil Engn & Architecture, Hangzhou 310058, Peoples R China
[6] Zhejiang Univ Technol, Inst Geotech Engn, Hangzhou 310014, Peoples R China
[7] ChengdunSuian Underground Engn Co Ltd, Shanghai 201108, Peoples R China
[8] Hangzhou City Univ, Dept Civil Engn, Hangzhou, Zhejiang, Peoples R China
关键词
Ground load; Shield tunnel reinforcement; Full-scale three-ring test; Structural characteristics; Reinforcement effects; MECHANICAL-BEHAVIOR;
D O I
10.1016/j.istruc.2024.105865
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate the internal force response characteristics and reinforcement effects of the shield tunnel segment structure in the presence of ground load disturbances in the Hangzhou Metro, full-scale tests were conducted on three-ring misaligned assembled segments using a self-developed "Shield Tunnel Segment Hydraulic Loading System." The study examined the structural characteristics of tunnel segments under the influence of different ground resistance coefficients (lambda) and eccentric loads (P), and explored the reinforcement effects of the internal tension ring method from multiple perspectives. The research results indicate that under different ground resistance coefficients (lambda), the sensitivity of internal force response is concentrated in the waist concrete, with a maximum bending moment reduction of 88.8%. The effective rate of bending stiffness tends to flatten, joint bending moment transfer effects strengthen, and the bearing capacity of the segments significantly increases after reinforcement, leading to a more uniform overall structural response. Under different eccentric loads (P), the bending moment of the segments after reinforcement approximates central symmetry with a reduced distribution range. The rate of change of the effective bending stiffness (eta) shifts from "rapid" to "slow," and the variation of joint bending moment transfer coefficient (zeta) stabilizes. The reinforcement with steel rings significantly enhances the overall stiffness of the segments and reinforces the joint bending moment transfer effect. The reinforcement effect of the segments can be evaluated through the bending moment transfer coefficient and effective bending stiffness. After reinforcement, the bearing capacity of the segments is noticeably enhanced, and significant forces are observed at two locations in the right waist joint, where the combination of steel plates and segments exhibits optimal performance.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [21] Structural performance of hammerhead pier under eccentric loads: strut-and-tie modeling, finite element method, and full-scale experimental study
    Wang, Xu
    Liu, Zhao
    Wang, Erqiang
    Alsomiri, Mujahed
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2024, 20 (06) : 802 - 818
  • [22] Loads Correlation of a Full-Scale UH-60A Air loads Rotor in a Wind Tunnel
    Yeo, Hyeonsoo
    Romander, Ethan A.
    JOURNAL OF THE AMERICAN HELICOPTER SOCIETY, 2013, 58 (02)
  • [23] Experimental study of aerodynamic and structural damping in a full-scale rotating turbine
    Kielb, JJ
    Abhari, RS
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2003, 125 (01): : 102 - 112
  • [24] Structural Characterization of an Historical Building by Means of Experimental Tests on Full-Scale Elements
    Bovo, Marco
    Mazzotti, Claudio
    Savoia, Marco
    ADVANCES IN CIVIL ENGINEERING, 2017, 2017
  • [25] Laminated connections for structural glass components: a full-scale experimental study
    Santarsiero M.
    Louter C.
    Nussbaumer A.
    Glass Structures & Engineering, 2017, 2 (1) : 79 - 101
  • [26] Full-scale experimental study on fire under natural ventilation in the T-shaped and curved tunnel groups
    Cheng, Huihang
    Liu, Chang
    Chen, Junfeng
    Wu, Le
    Zhao, Yuting
    Zhong, Maohua
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 123
  • [27] Experimental and Numerical Modelling of Shear Behaviour of Full-scale RC Slabs Under Concentrated Loads
    Nana, W. S. A.
    Bui, T. T.
    Limam, A.
    Abouri, S.
    STRUCTURES, 2017, 10 : 96 - 116
  • [28] Full-scale test on seismic performance of circumferential joint of shield-driven tunnel
    Guo, Xiangyu
    Geng, Ping
    Wang, Qi
    Chen, Changjian
    Tang, Rui
    Yang, Qi
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 151 (151)
  • [29] Experimental study on lining response of metro shield tunnel under the influence of ground cavity
    Guan, Feng
    Wei, Duqiang
    Lei, Jinshan
    Shi, Yufeng
    Cao, Chengwei
    Journal of Railway Science and Engineering, 2022, 19 (02): : 461 - 469
  • [30] Full-scale experimental measurement of barge impact loads on bridge piers
    Consolazio, Gary R.
    Cowan, David R.
    Biggs, Alexander
    Cook, Ronald A.
    Ansley, Marcus
    Bollmann, Henry T.
    SOIL MECHANICS 2005, 2005, (1936): : 81 - 93