Prevalence and management of electrical lead abnormalities in cardiac implantable electronic device leads

被引:3
|
作者
Roberts, Hilary [1 ]
Matheson, Kara [2 ]
Sapp, John [3 ]
Gardner, Martin [3 ]
Gray, Chris [3 ]
AbdelWahab, Amir [3 ]
Lee, David [3 ]
MacIntyre, Ciorsti [4 ]
Parkash, Ratika [3 ,5 ]
机构
[1] Dalhousie Univ, Fac Med, Dept Med, Halifax, NS, Canada
[2] Nova Scotia Hlth Author, Res Methods Unit, Halifax, NS, Canada
[3] Queen Elizabeth 2 Hlth Sci Ctr, Div Cardiol, Halifax, NS, Canada
[4] Mayo Clin, Dept Med, Rochester, MN USA
[5] 1796 Summer St, Room 2501A, Halifax, NS B3H 3A7, Canada
来源
HEART RHYTHM O2 | 2023年 / 4卷 / 07期
关键词
Cardiac implantable electronic devices; Lead failure; Pacing leads; Tendril leads; Electrical noise; CANADIAN WORKING GROUP; CONSENSUS STATEMENT; RIATA LEAD; FOLLOW-UP; FAILURE; GUIDELINES; PREDICTORS; PACEMAKER;
D O I
10.1016/j.hroo.2023.05.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Electrical lead abnormalities (ELAs) can result in device malfunction, leading to significant morbidity in patients with cardiac implantable electronic devices (CIEDs). OBJECTIVE We sought to determine the prevalence and management of ELAs in patients with CIEDs. METHODS This was a retrospective cohort study of patients implanted with a CIED between 2012 and 2019 at a tertiary care center. The primary outcome was ELA defined as increased capture threshold (>2! implantation value), decreased sensing (<0.5 implantation value), change in impedance (.50% over 3 months), or nonphysiologic potentials. A secondary outcome of device clinic utilization was also collected. RESULTS There were 2996 unique patients (35% female) included with 4600 leads (57% Abbott, 43% Medtronic). ELAs were observed in 135 (3%) leads, including 124 (92%) Abbott and 10 (7%) Medtronic leads (hazard ratio 9.25, P < .001). Mean follow-up was 4.5 6 2.2 years. ELAs were associated smaller lead French size, atrial location, and Abbott leads. Lead revision was required in 28% of cases. Patients with lead abnormalities had 38% more in-clinic visits per patient year of follow-up compared with those without (P < .001). CONCLUSION ELAs were more frequent in certain models, which increased rates of revision and follow-up. Identification of factors that mitigate these abnormalities to improve lead performance are required to improve care for these devices and provide efficient healthcare.
引用
收藏
页码:417 / 426
页数:10
相关论文
共 50 条
  • [21] Cardiac Implantable Electronic Device Lead-Induced Tricuspid Regurgitation
    Addetia, Karima
    Harb, Serge C.
    Hahn, Rebecca T.
    Kapadia, Samir
    Lang, Roberto M.
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (04) : 622 - 636
  • [22] Predictors of Early Cardiac Implantable Electronic Device Lead Dislodgement in the Elderly
    Mlynarski, Rafal
    Mlynarska, Agnieszka
    Joniec, Michal
    Gladysz-Wanha, Sylwia
    Honkowicz, Maciej
    Stachanczyk, Joanna
    Golba, Krzysztof S.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (22)
  • [23] Cardiac implantable electronic devices: Leads can lead to tricuspid regurgitation and death!
    Dreyfus, Julien
    Messika-Zeitoun, David
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 372 : 91 - 92
  • [24] Incidental non-infectious masses on cardiac implantable electronic device leads
    Fernandes, S.
    Dias, M.
    Conde, I
    Silva, R.
    Ferreira, C.
    Vilela, F.
    Mane, F.
    Marques, J.
    Vieira, C.
    Rocha, S.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [25] Anesthetic Management of a Surgical Patient With Cardiac Implantable Electrical Device
    Ramachandran, Sujatha
    Janelle, Gregory
    Aleong, Ryan
    Berger, Jay
    Krumerman, Andrew
    McKillop, Matthew
    Weitzel, Nathaen
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 16 (03) : 166 - 175
  • [26] Anaesthetic management of a pregnant patient with cardiac implantable electronic device
    Nair, U.
    Aggarwal, V.
    Jain, A.
    ANAESTHESIA, 2018, 73 : 84 - 84
  • [27] Conservative therapy for the management of cardiac implantable electronic device infection
    Sekiguchi, Yukio
    JOURNAL OF ARRHYTHMIA, 2016, 32 (04) : 293 - 296
  • [28] Electrical Interaction between Implantable Vagus Nerve Stimulation Device and Implantable Cardiac Rhythm Management Device
    Libbus, Imad
    Mazar, Scott T.
    Stubbs, Scott R.
    KenKnight, Bruce H.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3681 - 3684
  • [29] Risk of Collateral Lead Damage in Percutaneous Cardiac Implantable Electronic Device Extraction
    Khan, Faris
    Sverin, Gustaf
    Birgersdotter-Green, Ulrika
    Miller, Jennifer P.
    Lalani, Gautam
    Pollema, Travis
    Pretorius, Victor
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (02) : 193 - 200
  • [30] Evaluation of cardiac implantable electronic device lead parameters before and after radiotherapy
    Larsen, Mia Bang
    Jakobsen, Annette Ross
    Lundbye-Christensen, Soren
    Riahi, Sam
    Thogersen, Anna Margrethe
    Zaremba, Tomas
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (09): : 1176 - 1184