Prevalence and management of electrical lead abnormalities in cardiac implantable electronic device leads

被引:3
|
作者
Roberts, Hilary [1 ]
Matheson, Kara [2 ]
Sapp, John [3 ]
Gardner, Martin [3 ]
Gray, Chris [3 ]
AbdelWahab, Amir [3 ]
Lee, David [3 ]
MacIntyre, Ciorsti [4 ]
Parkash, Ratika [3 ,5 ]
机构
[1] Dalhousie Univ, Fac Med, Dept Med, Halifax, NS, Canada
[2] Nova Scotia Hlth Author, Res Methods Unit, Halifax, NS, Canada
[3] Queen Elizabeth 2 Hlth Sci Ctr, Div Cardiol, Halifax, NS, Canada
[4] Mayo Clin, Dept Med, Rochester, MN USA
[5] 1796 Summer St, Room 2501A, Halifax, NS B3H 3A7, Canada
来源
HEART RHYTHM O2 | 2023年 / 4卷 / 07期
关键词
Cardiac implantable electronic devices; Lead failure; Pacing leads; Tendril leads; Electrical noise; CANADIAN WORKING GROUP; CONSENSUS STATEMENT; RIATA LEAD; FOLLOW-UP; FAILURE; GUIDELINES; PREDICTORS; PACEMAKER;
D O I
10.1016/j.hroo.2023.05.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Electrical lead abnormalities (ELAs) can result in device malfunction, leading to significant morbidity in patients with cardiac implantable electronic devices (CIEDs). OBJECTIVE We sought to determine the prevalence and management of ELAs in patients with CIEDs. METHODS This was a retrospective cohort study of patients implanted with a CIED between 2012 and 2019 at a tertiary care center. The primary outcome was ELA defined as increased capture threshold (>2! implantation value), decreased sensing (<0.5 implantation value), change in impedance (.50% over 3 months), or nonphysiologic potentials. A secondary outcome of device clinic utilization was also collected. RESULTS There were 2996 unique patients (35% female) included with 4600 leads (57% Abbott, 43% Medtronic). ELAs were observed in 135 (3%) leads, including 124 (92%) Abbott and 10 (7%) Medtronic leads (hazard ratio 9.25, P < .001). Mean follow-up was 4.5 6 2.2 years. ELAs were associated smaller lead French size, atrial location, and Abbott leads. Lead revision was required in 28% of cases. Patients with lead abnormalities had 38% more in-clinic visits per patient year of follow-up compared with those without (P < .001). CONCLUSION ELAs were more frequent in certain models, which increased rates of revision and follow-up. Identification of factors that mitigate these abnormalities to improve lead performance are required to improve care for these devices and provide efficient healthcare.
引用
收藏
页码:417 / 426
页数:10
相关论文
共 50 条
  • [1] Reliability of cardiac implantable electronic device leads
    Kennergren, Charles
    EUROPACE, 2013, 15 (02): : 165 - 166
  • [2] Transvenous management of cardiac implantable electronic device late lead perforation
    Jessel, Peter M.
    Yadava, Mrinal
    Nazer, Babak
    Dewland, Thomas A.
    Miller, Jared
    Stecker, Eric C.
    Bhamidipati, Castigliano M.
    Song, Howard K.
    Henrikson, Charles A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (02) : 521 - 528
  • [3] The management of cardiac implantable electronic device lead perforations: a multicentre study
    Acha, Moshe Rav
    Rafael, Allon
    Keaney, John J.
    Elitzur, Yair
    Danon, Asaf
    Shauer, Ayelet
    Taha, Louay
    Shechter, Yonat
    Bogot, Naama R.
    Luria, David
    Ilan, Michael
    Singh, Sheldon M.
    Mela, Theofanie
    Weisz, Giora
    Glikson, Michael
    Medina, Aharon
    EUROPACE, 2019, 21 (06): : 937 - 943
  • [4] Transvenous removal of cardiac implantable electronic device leads
    Ribeiro, Silvia
    Leite, Luis
    Oliveira, Joao
    Pereira, Maria Joao
    Pinheiro, Carla
    Ermida, Paulo
    Antonio, Natalia
    Ventura, Miguel
    Cristovao, Joao
    Elvas, Luis
    Providencia, Luis
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2015, 34 (12) : 739 - 744
  • [5] Terminology Management for Implantable Cardiac Electronic Device Lead Macro-Dislodgement
    Arias, Miguel A.
    Pachon, Marta
    Puchol, Alberto
    Jimenez-Lopez, Jesus
    Rodriguez-Picon, Blanca
    Rodriguez-Padial, Luis
    REVISTA ESPANOLA DE CARDIOLOGIA, 2012, 65 (07): : 671 - 673
  • [6] Management of Cardiac Implantable Electronic Device Infection
    Podoleanu, Cristian
    Deharo, Jean-Claude
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2014, 3 (03) : 184 - 189
  • [7] Lead extraction for cardiac implantable electronic device infection: comparable complication rates with or without abandoned leads
    Bracke, Frank
    Verberkmoes, Niels
    van't Veer, Marcel
    van Gelder, Berry
    EUROPACE, 2019, 21 (09): : 1378 - 1384
  • [8] Late Perforation by Cardiac Implantable Electronic Device Leads: Clinical Presentation, Diagnostic Clues, and Management
    Refaat, Marwan M.
    Hashash, Jana G.
    Shalaby, Alaa A.
    CLINICAL CARDIOLOGY, 2010, 33 (08) : 466 - 475
  • [9] Incidence of subclinical cardiac perforation by cardiac implantable electronic device leads in cardiac CT
    Uhm, J. -S.
    Lim, Y. M.
    Yang, P. S.
    Kim, J. Y.
    Pak, H. N.
    Yu, H. T.
    Kim, T. H.
    Joung, B.
    Lee, M. H.
    EUROPEAN HEART JOURNAL, 2017, 38 : 364 - 364
  • [10] Mobile thrombus on cardiac implantable electronic device leads of patients undergoing cardiac ablation: incidence, management, and outcomes
    Alan Sugrue
    Christopher V. DeSimone
    Charles J. Lenz
    Douglas L. Packer
    Samuel J. Asirvatham
    Journal of Interventional Cardiac Electrophysiology, 2016, 46 : 115 - 120