Design of a Parallel Wrist Rehabilitation Robot and Analysis of Physiological Effect on Training

被引:0
|
作者
Zhang, Leiyu [1 ]
Yu, Zhendong [1 ]
Su, Peng [2 ]
Li, Jianfeng [1 ]
Ge, Ruidong [3 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Adv Mfg Technol, Beijing 100124, Peoples R China
[2] Beijing Informat Sci & Technol Univ, Sch Elect Engn, Beijing 100192, Peoples R China
[3] China Japan Friendship Hosp, Dept Rehabil Med, Beijing 100029, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Wrist; Training; Exoskeletons; Actuators; Read only memory; Physiology; Assistive robots; Energy transfer; human-machine interaction; muscular activation; parallel mechanism; wrist rehabilitation; ADMITTANCE CONTROL; EXOSKELETON; RICEWRIST;
D O I
10.1109/TMECH.2023.3344181
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Wrist impairments caused by stroke or long-term immobilization should be given more attention than the rehabilitation of proximal limb segments. In addition, the physiological effect of wrist exoskeletons on the training lacks sufficient research. According to the design requirements, a novel parallel wrist rehabilitation robot (PWRR) with two electric linear actuators and a passive prismatic joint was developed to achieve the training of the flexion/extension (F/E) and radial/ulnar deviation (R/U). The constraint forces caused by the axis misalignment were significantly reduced under the passive and active training by 0.75 +/- 0.22 N and 2.50 +/- 0.72 N, respectively. The total work of the active training increased with the velocity, whereas it was much smaller and had no obvious linear relationship with the velocity for the passive training. The sequence and degree of muscular activation of targeted muscles were measured and analyzed at three velocities to reveal the effects of the training mode and velocity on the physiological effects. PWRR could achieve the isometric training of wrist muscles at any angle of F/E and R/U validated by the comparative experiments of this device and weights. At each interactive force, the median frequency (MNF) of the EMG power spectrum and the average rectified value (ARV) of its amplitude decreased with increasing training time. The MNF slope increased with interactive thresholds, where the maximum slope was (-29.5 +/- 2.42) x10(-3)%/s at 15 N. Conversely, the ARV slope gradually decreased with the thresholds, where the maximum slope was (-61.0 +/- 8.55) x100(-3)%/s at 5 N.
引用
收藏
页码:3401 / 3414
页数:14
相关论文
共 50 条
  • [41] Design of a spherical wrist with parallel architecture: Application to vertebrae of an eel robot
    Chablat, D
    Wenger, P
    2005 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-4, 2005, : 3336 - 3341
  • [42] Fuzzy Logic-Based Risk Assessment of a Parallel Robot for Elbow and Wrist Rehabilitation
    Tucan, Paul
    Gherman, Bogdan
    Major, Kinga
    Vaida, Calin
    Major, Zoltan
    Plitea, Nicolae
    Carbone, Giuseppe
    Pisla, Doina
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (02)
  • [43] Robot-aided neurorehabilitation: A robot for wrist rehabilitation
    Krebs, Hermano Igo
    Volpe, Bruce T.
    Williams, Dustin
    Celestino, James
    Charles, Steven K.
    Lynch, Daniel
    Hogan, Neville
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2007, 15 (03) : 327 - 335
  • [44] Design of rehabilitation robot hand for fingers CPM training
    Zhou, Hongfu
    Chan, T. W.
    Tong, K. Y.
    Kwong, K. K.
    Yao, Xifan
    FIFTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, 2009, 7133
  • [45] A mechanism design and adjusting method of rehabilitation training robot
    Jiang, Lijie
    Wang, Yong
    Gao, Aili
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2015, 43 : 280 - 283
  • [46] Design and Passive Training Control of Elbow Rehabilitation Robot
    Cui, Xiaohong
    Wang, Binrui
    Lu, Han
    Chen, Jiayu
    ELECTRONICS, 2021, 10 (10)
  • [47] Design and Analysis of a Flexible Parallel Robot for Rope-Driven Upper Limb Rehabilitation
    Pang, Zaixiang
    Deng, Xiaomeng
    Gong, Linan
    Wang, Nan
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2024, PT III, 2025, 15203 : 45 - 59
  • [48] Mechanism design and analysis of a hybrid-input parallel rehabilitation robot with humanoid gaits
    Jiang L.
    Wang L.
    Wang Y.
    Chen J.
    Wang, Yong (simenkouwang@sina.com), 1600, Chinese Academy of Sciences (38): : 495 - 503
  • [49] RETRACTED: Design and Workspace Analysis of a Parallel Ankle Rehabilitation Robot (PARR) (Retracted Article)
    Zhang, Leiyu
    Li, Jianfeng
    Dong, Mingjie
    Fang, Bin
    Cui, Ying
    Zuo, Shiping
    Zhang, Kai
    JOURNAL OF HEALTHCARE ENGINEERING, 2019, 2019
  • [50] Design and Inverse Kinematics Analysis of Wrist Parallel Rehabilitation Mechanism: A Rope Driven-based Method
    Zhang B.
    Liu S.
    Yu J.
    Pang Z.
    Zhang X.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2022, 58 (05): : 57 - 68