Development and validation of an LC-MS/MS method for the quantification of KRASG12C inhibitor opnurasib in several mouse matrices and its application in a pharmacokinetic mouse study

被引:1
|
作者
Retmana, Irene A. [1 ,2 ]
Celebi, Nefise [2 ]
Rijmers, Jamie [1 ]
Schinkel, Alfred H. [1 ]
Beijnen, Jos H. [3 ,4 ]
Sparidans, Rolf W. [2 ]
机构
[1] Netherlands Canc Inst, Div Pharmacol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[2] Univ Utrecht, Fac Sci, Dept Pharmaceut Sci, Div Pharmacol, Univ Sweg 99, NL-3584 CG Utrecht, Netherlands
[3] Netherlands Canc Inst, Dept Pharm & Pharmacol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[4] Univ Utrecht, Fac Sci, Dept Pharmaceut Sci, Div Pharmacoepidemiol & Clin Pharmacol, Univ Sweg 99, NL-3584 CG Utrecht, Netherlands
关键词
Opnurasib; KRAS(G12C) inhibitor; LC-MS/MS; Bioanalysis; Mouse matrices;
D O I
10.1016/j.jchromb.2023.123964
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Opnurasib (JDQ-443) is a highly potent and promising KRAS(G12C) inhibitor that is currently under clinical investigation. Results of the ongoing clinical research demonstrated the acceptable safety profile and clinical activity of this drug candidate as a single agent for patients with NSCLC harboring KRAS(G12C) mutations. In this early stage of development, a deeper insight into pharmacokinetic properties in both preclinical and clinical investigations of this drug is very important. Thus, a reliable quantification method is required. To date, no quantitative bioanalytical assay of opnurasib was publicly available. In this study we present a validated assay to quantify opnurasib in mouse plasma and eight mouse tissue-related matrices utilizing liquid chromatographytandem mass spectrometry. Erlotinib was used as internal standard and acetonitrile was utilized to treat 10 mu l of the sample with protein precipitation in a 96-well plate format. Separation and detection were achieved using a BEH C18 column under basic chromatographic conditions and a triple quadrupole mass spectrometer, respectively. We have fully validated this assay for mouse plasma and partially for eight mouse tissue-related matrices over the range of 2-2000 ng/ml. The accuracy and precision of the assay fulfilled international guidelines (EMA & U.S. FDA) over the validated range. The method was proven selective and sensitive to quantify opnurasib down to 2 ng/ml in all investigated matrices. The recoveries of both analyte and internal standard in mouse plasma were similar to 100 % with no significant matrix effect in any of the matrices. Opnurasib in mouse plasma was stable up to 12 h at room temperature, and up to 8 h at room temperature in tissue homogenates (except for kidney up to 4 h). This presented method has been successfully applied to quantify opnurasib in preclinical samples from a mouse study and demonstrated its usability to support preclinical pharmacokinetic studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Development and validation of an LC-MS/MS method for the determination of tofogliflozin in plasma and its application to a pharmacokinetic study in rats
    Kobuchi, Shinji
    Matsuno, Megumi
    Fukuda, Etsuko
    Ito, Yukako
    Sakaeda, Toshiyuki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1027 : 227 - 233
  • [22] Development and validation of an LC-MS/MS method for the determination of tolvaptan in human plasma and its application to a pharmacokinetic study
    Pei, Qi
    Zhang, Bikui
    Tan, Hongyi
    Liu, Lihua
    Peng, Xiangdong
    Li, Zuojun
    Huang, Panhao
    Luo, Mi
    Zuo, Xiaocong
    Guo, Chengxian
    Yang, Guoping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 913 : 84 - 89
  • [23] Development and validation of an LC-MS/MS method for the quantification of artificial sweeteners in human matrices
    Greibe, Eva
    Leth-Moller, Magnus
    Stampe, Sofie
    Ovesen, Per
    Pedersen, Michael
    Hoffmann-Lucke, Elke
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (06)
  • [24] Development and validation of an LC-MS/MS method for monitoring larotrectinib, a tropomyosin-related kinase inhibitor, in mouse and human plasma and application to pharmacokinetic studies
    Yoon-Jee Chae
    Yoo-Kyung Song
    Song-Hee Chae
    Min Ju Kim
    Jong Soon Kang
    Jae-Young Lee
    Tae-Sung Koo
    Kyeong-Ryoon Lee
    Journal of Analytical Science and Technology, 11
  • [25] Development and validation of an LC-MS/MS method for monitoring larotrectinib, a tropomyosin-related kinase inhibitor, in mouse and human plasma and application to pharmacokinetic studies
    Chae, Yoon-Jee
    Song, Yoo-Kyung
    Chae, Song-Hee
    Kim, Min Ju
    Kang, Jong Soon
    Lee, Jae-Young
    Koo, Tae-Sung
    Lee, Kyeong-Ryoon
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2020, 11 (01)
  • [26] LC-MS-MS Method for Quantification of Hydralazine in BALB/C Mouse Plasma and Brain: Application to Pharmacokinetic Study
    Liu, Yanying
    Li, Hui
    Luo, Hongjun
    Lin, Zhexuan
    Luo, Wenhong
    CHROMATOGRAPHIA, 2011, 73 (11-12) : 1183 - 1188
  • [27] Development and Validation of LC-MS/MS Assay for the Quantification of Progesterone in Rat Plasma and its Application to Pharmacokinetic Studies
    Sasaki, M.
    Ochiai, H.
    Takahashi, K.
    Suzuki, R.
    Minato, K.
    Fujikata, A.
    DRUG RESEARCH, 2015, 65 (09) : 484 - 489
  • [28] Development and validation of an LC-MS/MS method for pharmacokinetic study of lobetyolin in rats
    Tian, Haitao
    Zhao, Pan
    Li, Jing
    Deng, Zhipeng
    Pu, Gaobin
    Wang, Hong
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 58
  • [29] Development and validation of sensitive LC-MS/MS method for the quantification of SUVN-502 and its metabolite and its application for first in human pharmacokinetic study
    Nirogi, Ramakrishna
    Ajjala, Devender Reddy
    Aleti, Raghupathi
    Rayapati, Lakshmiprasanna
    Pantangi, Hanumanth Rao
    Boggavarapu, Rajesh Kumar
    Padala, Naga Surya Prakash
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 : 423 - 430
  • [30] Development and validation of a reliable and rapid LC-MS/MS method for simultaneous quantification of sacubitril and valsartan in rat plasma and its application to a pharmacokinetic study
    Chunduri, Raja Haranadha Babu
    Dannana, Gowri Sankar
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (09) : 1467 - 1475