Development of a voxel S-value database for patient internal radiation dosimetry

被引:1
|
作者
Xin, Lin [1 ]
Zhuo, Weihai [1 ]
Xie, Tianwu [1 ]
机构
[1] Fudan Univ, Inst Radiat Med, 2094 Xietu Rd, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
Voxel phantom; Voxel S-values; Internal radiation dosimetry; Computational model; Monte Carlo simulations; MONTE-CARLO SIMULATIONS; KERNEL CONVOLUTION; GATE; TOOLKIT; VALIDATION; PET;
D O I
10.1016/j.ejmp.2022.102519
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Personalized dosimetry with high accuracy drew great attention in clinical practices. Voxel S-value (VSV) convolution has been proposed to speed up absorbed dose calculations. However, the VSV method is efficient for personalized internal radiation dosimetry only when there are pre-calculated VSVs of the radio-isotope. In this work, we propose a new method for VSV calculation based on the developed mono-energetic particle VSV database of gamma, beta, alpha, and X-ray for any radioisotopes.Methods: Mono-energetic VSV database for gamma, beta, alpha, and X-ray was calculated using Monte Carlo methods. Radi-ation dose was first calculated based on mono-energetic VSVs for [F-18]-FDG in 10 patients. The estimated doses were compared with the values obtained from direct Monte Carlo simulation for validation of the proposed method. The number of VSVs used in calculation was optimized based on the estimated dose accuracy and computation time.Results: The generated VSVs showed a great consistency with the results calculated using direct Monte Carlo simulation. For [F-18]-FDG, the proposed VSV method with number of VSV of 9 shows the best relative average organ absorbed dose uncertainty of 3.25% while the calculation time was reduced by 99% and 97% compared to the Monte Carlo simulation and traditional multiple VSV methods, respectively.Conclusions: In this work, we provided a method to generate the VSV kernels for any radioisotope based on the pre-calculated mono-energetic VSV database and significantly reduced the time cost for the multiple VSVs dosimetry approach. A software was developed to generate VSV kernels for any radioisotope in 19 mediums.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] AN INTERNAL RADIATION DOSIMETRY COMPUTER PROGRAM, IDAC 2.0, FOR ESTIMATION OF PATIENT DOSES FROM RADIOPHARMACEUTICALS
    Andersson, M.
    Johansson, L.
    Minarik, D.
    Mattsson, S.
    Leide-Svegborn, S.
    RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 299 - 305
  • [22] Comparison of different voxel-S-value methods for quantitative Y-90 TOF PET dosimetry
    Chen, G.
    Dewaraja, Y.
    Mok, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S241 - S242
  • [23] 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic
    Maneru, F.
    Otal, A.
    Gracia, M.
    Gallardo, N.
    Olasolo, J.
    Fuentemilla, N.
    Bragado, L.
    Martin-Albina, M.
    Lozares, S.
    Pellejero, S.
    Miquelez, S.
    Rubio, A.
    MEDICAL PHYSICS, 2015, 42 (06) : 3330 - 3331
  • [24] An analytical method for computing 177Lu Voxel S-Values for 3D internal dosimetry
    Pistone, D.
    Auditore, L.
    Italiano, A.
    Amato, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S638 - S639
  • [25] Preclinical radiation internal dosimetry in the development of new radiopharmaceuticals using GATE Monte Carlo simulation
    Silva, Catherine C. O.
    Berdeguez, Mirta B. T.
    Barboza, Thiago
    Souza, Sergio A. L.
    Braz, Delson
    Silva, Ademir X.
    Sa, Lidia, V
    RADIATION PHYSICS AND CHEMISTRY, 2020, 173
  • [26] Voxel-S-value methods adapted to heterogeneous media for quantitative Y-90 microsphere radioembolization dosimetry
    Chen, Gefei
    Lu, Zhonglin
    Chen, Yue
    Mok, Greta S. P.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (01): : 35 - 45
  • [27] Monte-Carlo (MC) simulation and calculation of the specific absorbed fractions (SAFs) of radiation energy for internal dosimetry using a VOXEL phantom of a piglet
    Kranz, Mathias
    Sattler, Bernhard
    Desbree, Aurelie
    Rullmann, Michael
    Deuther-Conrad, Winnie
    Steinbach, Joerg
    Brust, Peter
    Sabri, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [28] Personalized Voxel-S-Value Methods for Monte-Carlo-like Quantitative Y-90 PET Dosimetry
    Chen, Gefei
    Lu, Zhonglin
    Mok, Greta
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [29] Evaluation of Lung Dose Using Voxel-based Dosimetry with SPECT/CT for Yttrium-90 Selective Internal Radiation Therapy of Liver Cancer
    Potrebko, P.
    Andl, G.
    Bose, S.
    Fox, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E725 - E725
  • [30] 90Y Voxel S-Values updated Monte Carlo database including Internal Bremsstrahlung and new analytical model extending the evaluation to any voxel size
    Pistone, D.
    Auditore, L.
    Italiano, A.
    Amato, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S406 - S406