Development of a voxel S-value database for patient internal radiation dosimetry

被引:1
|
作者
Xin, Lin [1 ]
Zhuo, Weihai [1 ]
Xie, Tianwu [1 ]
机构
[1] Fudan Univ, Inst Radiat Med, 2094 Xietu Rd, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
Voxel phantom; Voxel S-values; Internal radiation dosimetry; Computational model; Monte Carlo simulations; MONTE-CARLO SIMULATIONS; KERNEL CONVOLUTION; GATE; TOOLKIT; VALIDATION; PET;
D O I
10.1016/j.ejmp.2022.102519
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Personalized dosimetry with high accuracy drew great attention in clinical practices. Voxel S-value (VSV) convolution has been proposed to speed up absorbed dose calculations. However, the VSV method is efficient for personalized internal radiation dosimetry only when there are pre-calculated VSVs of the radio-isotope. In this work, we propose a new method for VSV calculation based on the developed mono-energetic particle VSV database of gamma, beta, alpha, and X-ray for any radioisotopes.Methods: Mono-energetic VSV database for gamma, beta, alpha, and X-ray was calculated using Monte Carlo methods. Radi-ation dose was first calculated based on mono-energetic VSVs for [F-18]-FDG in 10 patients. The estimated doses were compared with the values obtained from direct Monte Carlo simulation for validation of the proposed method. The number of VSVs used in calculation was optimized based on the estimated dose accuracy and computation time.Results: The generated VSVs showed a great consistency with the results calculated using direct Monte Carlo simulation. For [F-18]-FDG, the proposed VSV method with number of VSV of 9 shows the best relative average organ absorbed dose uncertainty of 3.25% while the calculation time was reduced by 99% and 97% compared to the Monte Carlo simulation and traditional multiple VSV methods, respectively.Conclusions: In this work, we provided a method to generate the VSV kernels for any radioisotope based on the pre-calculated mono-energetic VSV database and significantly reduced the time cost for the multiple VSVs dosimetry approach. A software was developed to generate VSV kernels for any radioisotope in 19 mediums.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of voxel S-value methods for personalized voxel-based dosimetry of 177Lu-DOTATATE
    Kim, Keon Min
    Lee, Min Sun
    Suh, Min Seok
    Selvam, Haniff Shazwan Muhd Safwan
    Tan, Teik Hin
    Cheon, Gi Jeong
    Kang, Keon Wook
    Lee, Jae Sung
    MEDICAL PHYSICS, 2022, 49 (03) : 1888 - 1901
  • [2] Development and validation of a comprehensive S-value database for small animal internal dosimetry in nuclear medicine using the DM_Bra mouse phantom
    Laazouzi, Khaoula
    Cavedini, Nicollas Goncalves
    Belhaj, Omaima Essaad
    Hadouachi, Maryam
    Boukhal, Hamid
    Chakir, El mahjoub
    Jeckel, Cristina Maria Moriguchi
    da Silva, Ana Maria Marques
    Salas-Ramirez, Maikol
    RADIATION MEASUREMENTS, 2024, 178
  • [3] 177Lu-DOTATATE Dosimetry for Normal Organs and Tumors with Multiple Voxel S-Value Approach
    Kim, Keon Min
    Lee, Min Sun
    Suh, Min Seok
    Tan, Teik-Hin
    Selvam, Haniff Shazwan Muhd Safwan
    Cheon, Gi Jeong
    Kang, Keon Wook
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [4] S-value scaling using spongiosa volumes to improve patient-specific dosimetry
    Brindle, JM
    Shah, AP
    Watchman, CJ
    Rajon, DA
    Bolch, WE
    HEALTH PHYSICS, 2003, 84 (06): : S260 - S260
  • [5] Whole-Body Voxel-Based Personalized Dosimetry: The Multiple Voxel S-Value Approach for Heterogeneous Media with Nonuniform Activity Distributions
    Lee, Min Sun
    Kim, Joong Hyun
    Paeng, Jin Chul
    Kang, Keon Wook
    Jeong, Jae Min
    Lee, Dong Soo
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (07) : 1133 - 1139
  • [6] Voxel S-value based personalized dosimetry for predicting response to trans-arterial radioembolization therapy for hepatocellular carcinoma
    Suh, M.
    Kim, K.
    Paeng, J.
    Kim, H.
    Lee, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S367 - S367
  • [7] A Geant4-based Voxel S-value Generator For Radiopharmaceutical Therapy
    Bednarz, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S477 - S477
  • [8] Role of lung density in voxel-based dosimetry of90Y-TARE evaluated with Voxel S-Value (VSV) method and fast Monte Carlo simulation
    Moretti, R.
    Capotosti, A.
    Vaccaro, M.
    Ribeiro, C. D.
    Nardini, M.
    Meffe, G.
    Placidi, L.
    Zagaria, L.
    De Risi, M.
    Perotti, G.
    Leccisotti, L.
    Iezzi, R.
    Indovina, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S746 - S746
  • [9] Development and validation of a Medaka fish voxel-based model for internal ionizing radiation dosimetry
    EL Bakkali, Jaafar
    Doudouh, Abderrahim
    EL Bardouni, Tarek
    EL Ghalbzouri, Tarik
    Bendriss, Hafssa
    Yachou, Soufiyan
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2024, 272
  • [10] The Role of Lung Density in the Voxel-Based Dosimetry of 90Y-TARE Evaluated with the Voxel S-Value (VSV) Method and Fast Monte Carlo Simulation
    Capotosti, Amedeo
    Moretti, Roberto
    Vaccaro, Maria
    Ribeiro, Cintia De Almeida
    Placidi, Lorenzo
    Nardini, Matteo
    Meffe, Guenda
    Cusumano, Davide
    Zagaria, Luca
    De Risi, Marina
    Perotti, Germano
    Leccisotti, Lucia
    De Spirito, Marco
    Iezzi, Roberto
    Indovina, Luca
    APPLIED SCIENCES-BASEL, 2024, 14 (03):