The role of endobronchial ultrasonography elastography in the diagnosis of hilar and mediastinal lymph nodes

被引:2
|
作者
Demirkol, Baris [1 ]
Tanriverdi, Elif [2 ]
Gul, Sule [2 ]
Koc, Aysu Sinem [3 ]
Akgun, Elife [4 ]
Yardimci, Aytuel Hande [5 ]
Baydili, Kursad Nuri [6 ]
Cetinkaya, Erdogan [2 ]
机构
[1] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Pulmonol, Istanbul, Turkiye
[2] Univ Hlth Sci, Yedikule Chest Dis & Thorac Surg Educ & Res Hosp, Dept Pulmonol, Istanbul, Turkiye
[3] Istinye Univ, Bahcesehir Liv Hosp, Dept Pulmonol, Istanbul, Turkiye
[4] Kirikkale Yuksek Ihtisas Hosp, Dept Nucl Med, Kirikkale, Turkiye
[5] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Radiol, Istanbul, Turkiye
[6] Univ Hlth Sci, Fac Hamidiye Med, Dept Biostat & Med Informat, Istanbul, Turkiye
关键词
Elastography; endobronchial ultrasonography; lymph node; mediastinum; strain ratio; ULTRASOUND ELASTOGRAPHY; LUNG-CANCER; EBUS-TBNA; CLASSIFICATION;
D O I
10.55730/1300-0144.5634
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/aim: Endobronchial ultrasonography (EBUS) is a minimally invasive diagnostic tool in the diagnosis of mediastinal lymph nodes (LNs) and has sonographic features. We aimed to investigate the diagnostic accuracy of EBUS elastography, which evaluates tissue compressibility integrated into EBUS, on malignant vs. benign mediastinal-hilar LNs.Materials and methods: A single-center, prospective study was conducted at the University of Health Sciences Yedikule Chest Diseases and Thoracic Surgery Training and Research Hospital between 01/10/2019 and 15/11/2019. The features of 219 LNs evaluated by thoracic computed tomography (CT), positron emission tomography (PET)/CT, EBUS sonography and EBUS elastography were recorded. The LNs sampled by EBUS-guided fine needle aspiration were classified according to EBUS elastography color distribution findings as follows: type 1, predominantly nonblue (green, yellow, and red); type 2, part blue, part nonblue; type 3, predominantly blue. The strain ratio (SR) was calculated based on normal tissue with the relevant region.Results: The average age of 131 patients included in the study was 55.86 & PLUSMN; 13 years, 76 (58%) were male. Two hundred and nineteen lymph nodes were sampled from different stations. Pathological diagnosis of 75 (34.2%) LNs was malignant, the rest was benign. When EBUS B-mode findings and pathological results were compared, sensitivity was 65.33%, specificity 63.19%, positive predictive value (PPV) 48%, negative predictive value (NPV) 77.8%, and diagnostic yield (DY) 64%. When the pathological diagnoses and EBUS elastography findings were compared, while type 1 LNs were considered to be benign and type 3 LNs malignant, sensitivity 94.12%, specificity 86.54%, PPV 82.1%, NPV 95.7%, and DY 89.5%. SR of malignant LNs was significantly higher than benign LNs (p < 0.001). When the classification according to color scale and SR were compared, no difference was found in DY (p = 0.155).Conclusion: The diagnostic accuracy of EBUS elastography is high enough to distinguish malignant LN from benign ones with the SR option. When compared with EBUS-B mode sonographic findings, it was found to have a higher diagnostic yield.
引用
收藏
页码:712 / 720
页数:11
相关论文
共 50 条
  • [1] The role of endobronchial ultrasound elastography in the diagnosis of mediastinal and hilar lymph nodes
    Gu, Ye
    Shi, Hong
    Su, Chunxia
    Chen, Xiaoxia
    Zhang, Shijia
    Li, Wei
    Wu, Fengying
    Gao, Guanghui
    Wang, Hao
    Chu, Haiqing
    Zhou, Caicun
    Zhou, Fei
    Ren, Shengxiang
    ONCOTARGET, 2017, 8 (51) : 89194 - 89202
  • [2] ENDOBRONCHIAL ULTRASOUND ELASTOGRAPHY IN THE DIAGNOSIS OF MEDIASTINAL AND HILAR LYMPH NODES
    Izumo, T.
    Sasada, S.
    Chavez, C.
    Matsumoto, Y.
    Hayama, M.
    Tsuchida, T.
    RESPIROLOGY, 2014, 19 : 9 - 9
  • [3] Endobronchial Ultrasound Elastography in the Diagnosis of Mediastinal and Hilar Lymph Nodes
    Izumo, Takehiro
    Sasada, Shinji
    Chavez, Christine
    Matsumoto, Yuji
    Tsuchida, Takaaki
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2014, 44 (10) : 956 - 962
  • [4] Endobronchial ultrasound elastography type classification in the diagnosis of mediastinal and hilar lymph nodes
    Izumo, Takehiro
    Matsumoto, Yuji
    Hiraishi, Yoshihisa
    Hayama, Manabu
    Chavez, Christine
    Sasada, Shinji
    Tsuchida, Takaaki
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [5] Elastography in the diagnosis of hilar and mediastinal lymph nodes
    Gompelmann, Daniela
    Kontogianni, Konstantina
    Sarmand, Nilab
    Kaukel, Philine
    Eberhardt, Ralf
    Herth, Felix J. F.
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [6] The role of endobronchial ultrasound elastography in the diagnosis of mediastinal lymph nodes
    Adel S. Bediwy
    Mohamed S. Hantira
    Dalia El Sharawy
    Ayman El Saqa
    Egyptian Journal of Bronchology, 2017, 11 (3) : 238 - 243
  • [7] Endobronchial Ultrasound Elastography for Diagnosing Mediastinal and Hilar Lymph Nodes
    He Hai-Yan
    Huang Mao
    Zhu Jie
    Ma Hang
    Lyu Xue-Dong
    中华医学杂志英文版, 2015, 128 (20) : 2720 - 2725
  • [8] Endobronchial ultrasound elastography for diagnosing mediastinal and hilar lymph nodes
    Hernandez Roca, Maria
    Perez Pallares, Javier
    Salas, Maria del Mar Valdivia
    Garcia Solano, Jose
    Prieto Merino, David
    Martinez Diaz, Juan Jose
    Santa Cruz Siminiani, Antonio
    MEDICINA CLINICA, 2020, 154 (02): : 45 - 51
  • [9] Endobronchial Ultrasound Elastography for Diagnosing Mediastinal and Hilar Lymph Nodes
    He, Hai-Yan
    Huang, Mao
    Zhu, Jie
    Ma, Hang
    Lyu, Xue-Dong
    CHINESE MEDICAL JOURNAL, 2015, 128 (20) : 2720 - 2725
  • [10] Effectiveness of the Benign and Malignant Diagnosis of Mediastinal and Hilar Lymph Nodes by Endobronchial Ultrasound Elastography
    Huang, Haidong
    Huang, Zhiang
    Wang, Qin
    Wang, Xinan
    Dong, Yuchao
    Zhang, Wei
    Zarogoulidis, Paul
    Man, Yan-Gao
    Schmidt, Wolfgang Hohenforst
    Bai, Chong
    JOURNAL OF CANCER, 2017, 8 (10): : 1843 - 1848