Monitoring of Interfractional Proton Range Verification and Dosimetric Impact Based on Daily CBCT for Pediatric Patients with Pelvic Tumors

被引:1
|
作者
Ates, Ozgur [1 ]
Uh, Jinsoo [1 ]
Pirlepesov, Fakhriddin [1 ]
Hua, Chia-Ho [1 ]
Merchant, Thomas E. [1 ]
Krasin, Matthew J. [1 ]
机构
[1] St Jude Childrens Res Hosp, Memphis, TN 38105 USA
关键词
proton range uncertainty; water equivalent path length; pediatric pelvic tumors; interfractional range verification; synthetic CT; RADIOTHERAPY; THERAPY;
D O I
10.3390/cancers15174200
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The research highlights the application of synthetic CT images, which are created by deforming planning CT scans to match daily CBCT anatomy in interfractional proton therapy for pediatric patients with pelvic tumors. The objective of the study is to identify changes in the proton path length and determine the impact of anatomical changes on the treatment plan's quality. The findings reveal that the water equivalent path length method can effectively estimate proton range deviations on synthetic-CT images. The daily synthetic CT images can also be utilized as a surrogate to calculate dose and predict dosimetric changes in the plan of the day. This approach eliminates the need for frequent rescanning, thereby making the adaptive therapy process more streamlined and less burdensome for young patients. The results have the potential to improve the precision of proton therapy, hence paving the way for more effective treatments.Abstract (1) Background: Synthetic CT images of the pelvis were generated from daily CBCT images to monitor changes in water equivalent path length (WEPL) and determine the dosimetric impact of anatomy changes along the proton beam's path; (2) Methods: Ten pediatric patients with pelvic tumors treated using proton therapy with daily CBCT were included. The original planning CT was deformed to the same-day CBCT to generate synthetic CT images for WEPL comparison and dosimetric evaluation; (3) Results: WEPL changes of 20 proton fields at the distal edge of the CTV ranged from 0.1 to 12 mm with a median of 2.5 mm, and 75th percentile of 5.1 mm for (the original CT-rescanned CT) and ranged from 0.3 to 10.1 mm with a median of 2.45 mm and 75th percentile of 4.8 mm for (the original CT-synthetic CT). The dosimetric impact was due to proton range pullback or overshoot, which led to reduced coverage in CTV Dmin averaging 12.1% and 11.3% in the rescanned and synthetic CT verification plans, respectively; (4) Conclusions: The study demonstrated that synthetic CT generated by deforming the original planning CT to daily CBCT can be used to quantify proton range changes and predict adverse dosimetric scenarios without the need for excessive rescanned CT scans during large interfractional variations in adaptive proton therapy of pediatric pelvic tumors.
引用
收藏
页数:10
相关论文
共 34 条
  • [11] Dosimetric consequences of setup errors for patients with head and neck tumors in the context of daily dose verification
    Aubry, J.
    Cheung, J.
    Yom, S.
    Beaulieu, L.
    Pouliot, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S385 - S386
  • [12] Exvivo proton range uncertainty verification of dose calculation on CTand CBCT based synthetic ct
    Perez Moreno, J. M.
    Lorenzo Villanueva, I.
    Nilsson, R.
    Andersson, S.
    Vera Sanchez, J. A.
    Castro Novais, J.
    Cerron Campoo, F.
    Canals de las Casas, E.
    Janson, M.
    Engwall, E.
    Mazal, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1758 - S1760
  • [13] Interfractional body surface monitoring using daily cone-beam computed tomography imaging for pediatric adaptive proton therapy
    Ates, Ozgur
    Lee, Hoyeon
    Uh, Jinsoo
    Krasin, Matthew J.
    Merchant, Thomas E.
    Hua, Chia-ho
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 34
  • [14] Weekly dosimetric evaluation of CBCT-based synthetic CTs for proton therapy of head & neck patients
    de Koster, R.
    Thummerer, A.
    Marmitt, G. Guterres
    Scandurra, D.
    Langendijk, H.
    Both, S.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1389 - S1390
  • [15] Dosimetric and volumetric changes in the rectum and bladder in patients receiving CBCT-guided prostate IMRT: analysis based on daily CBCT dose calculation
    Pearson, David
    Gill, Sukhdeep K.
    Campbell, Nina
    Reddy, Krishna
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 107 - 117
  • [16] Impact of proton radiotherapy on treatment timing in pediatric and adult patients with CNS tumors
    Jin, Michael C.
    Shi, Siyu
    Wu, Adela
    Sandhu, Navjot
    Xiang, Michael
    Soltys, Scott G.
    Hiniker, Susan
    Li, Gordon
    Pollom, Erqi L.
    NEURO-ONCOLOGY PRACTICE, 2020, 7 (06) : 626 - 635
  • [17] Toward Online Adaptive Proton Therapy of Sinonasal Cancer: The Dosimetric Accuracy of Utilizing Deep- Learning Synthetic CT from CBCT for Daily Treatment Dose Verification
    Qin, A.
    Zhao, L.
    Chen, S.
    Li, X.
    Zheng, W.
    Yan, D.
    Deraniyagala, R.
    Ding, X.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [18] Brainstem Injury in Pediatric Patients With Posterior Fossa Tumors Treated With Proton Beam Therapy and Associated Dosimetric Factors
    Gentile, Michelle S.
    Yeap, Beow Y.
    Paganetti, Harald
    Goebel, Claire P.
    Gaudet, Dillon E.
    Gallotto, Sara L.
    Weyman, Elizabeth A.
    Morgan, Michael L.
    MacDonald, Shannon M.
    Giantsoudi, Drosoula
    Adams, Judith
    Tarbell, Nancy J.
    Kooy, Hanne
    Yock, Torunn I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (03): : 719 - 729
  • [19] Impact of Strict Brainstem Dosimetric Parameters on Symptomatic Brainstem Injury and Survival After Proton Beam Radiation in Pediatric Brain Tumors
    Upadhyay, Rituraj
    Grosshans, David
    McGovern, Susan
    McAleer, Mary
    Woodhouse, Kristina
    Zaky, Wafik
    Chintagumpala, Murali
    Mahajan, Anita
    Paulino, Arnold
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2021, 44 (10): : S133 - S133
  • [20] Dual-energy CT based proton range prediction in head and pelvic tumor patients
    Wohlfahrt, Patrick
    Moehler, Christian
    Stuetzer, Kristin
    Greilich, Steffen
    Richter, Christian
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) : 526 - 533