Anterolateral and Medial Locking Compression Plates for the Management of Distal Tibial Fractures: A Comparative Prospective Study

被引:0
|
作者
Kumar, Dinesh [1 ]
Mittal, Ankit [1 ]
Singh, Jasveer [1 ]
Kumar, Harish [1 ]
Singh, Prashant P. [1 ]
Kumar, Akash [1 ]
Singhania, Ashish [1 ]
Kant, Ravi [1 ]
机构
[1] Uttar Pradesh Univ Med Sci, Dept Pathol, Etawah, India
关键词
distal tibia locking compression plate; distal tibia fractures; internal fixation; close reduction; open; SHAFT FRACTURES; FIXATION; OUTCOMES;
D O I
10.7759/cureus.44235
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Open/close reduction (OR/CR) and internal fixation (IF) of displaced fractures of distal tibia with either a medial or anterolateral plate is a commonly performed procedure. Anterolateral plating avoids an incision along the medial subcutaneous border of tibia and has been shown to have reduced risk of wound complications. The aim of our study was to determine the functional outcome of these fractures treated with anterolateral and medial distal tibial locking compression plates.Methods: This was a prospective study that included 60 patients with distal tibial fractures (close or grade I open injury) divided into two groups with 30 patients in each where one group was treated with OR/CR and IF using an anterolateral distal tibial locking plate (Group A) and the other using a medial distal tibial locking plate (Group B). The duration of surgery and intraoperative blood loss and time to union were recorded for all the patients. Functional evaluation was done at one year in terms of pain, function and alignment using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale, and complications, if any, were noted.Results: Both the groups were comparable in terms of age, gender, time of presentation, AO classification and presence of wound. The mean duration of surgery as well as the intraoperative blood loss were more in the anterolateral plate group than in the medial plate group, but the difference was statistically insignificant. Ten patients (33%) with medial plates had symptomatic hardware and 7 (23.3%) underwent removal while only 3 (10%) patients in the anterolateral plate group had similar complaints and none had to undergo removal. Two patients with anterolateral plate and one with medial plate had malunion. The mean time to fracture union as well as the rate of infection was less and the functional outcome at one year was better in the group treated with anterolateral plates as compared to the one with medial plates, but the difference again was not statistically significant for all the parameters.Conclusion: With reduced risk of soft tissue complications and by obviating the need for implant removal, anterolateral plates can prove to be a better alternative to the medial plates especially in elderly patients in the management of these fractures.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Fixation of anterolateral distal tibial fractures: the anterior malleolus
    Rammelt, Stefan
    Bartonicek, Jan
    Schepers, Tim
    Kroker, Livia
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2021, 33 (02): : 125 - 138
  • [32] FRACTURES OF THE ANTEROLATERAL TUBERCLE OF THE DISTAL TIBIAL EPIPHYSIS IN ADOLESCENCE
    GILLE, P
    AUBERT, D
    TOULOUSE, J
    FRANCOIS, JY
    LECLERC, D
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1981, 67 (07): : 675 - 680
  • [33] Use of Locking Plates for Tibial Plateau Fractures
    Watson, J. Tracy
    TECHNIQUES IN ORTHOPAEDICS, 2007, 22 (04) : 219 - 226
  • [34] Locking plates in distal humerus fractures: study of 43 patients
    Gupta, Rakesh Kumar
    Gupta, Vinay
    Marak, Dickey Richard
    CHINESE JOURNAL OF TRAUMATOLOGY, 2013, 16 (04) : 207 - 211
  • [35] Comparative study of T-plates and locking plates in the management of displaced proximal humeral fractures
    Yan, Denglu
    Soon, Yancheng
    CURRENT ORTHOPAEDIC PRACTICE, 2012, 23 (04): : 351 - 355
  • [36] Locking plates in distal humerus fractures:study of 43 patients
    Rakesh Kumar Gupta
    Vinay Gupta
    Dickey Richard Marak
    中华创伤杂志(英文版), 2013, (04) : 207 - 211
  • [37] SURGICAL OUTCOME OF DISTAL FEMORAL FRACTURES TREATED WITH LOCKING COMPRESSION PLATE- A PROSPECTIVE STUDY
    Isaac, Jenson
    Krishnan, Vijay
    Sowmiya, K. R.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (25): : 1969 - 1973
  • [38] Is electromagnetic guidance system superior to a free-hand technique for distal locking in intramedullary nailing of tibial fractures? A prospective comparative study
    Aslan, Ahmet
    Konya, Mehmet Nuri
    Gulcu, Anil
    Sargin, Serdar
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2020, 26 (02): : 280 - 286
  • [39] MANAGEMENT OF DISTAL TIBIAL INTRA-ARTICULAR FRACTURES [TIBIAL PLAFOND] BY VARIOUS METHODS: A PROSPECTIVE STUDY
    Nagamuneendrudu, K.
    Srirangarao, Mettu
    Bogadhi, Harsha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (70): : 5081 - 5085
  • [40] SURGICAL MANAGEMENT OF FRACTURES OF DISTAL END OF RADIUS WITH LOCKING COMPRESSION PLATE
    Kamareddy, S. B.
    Patil, Pratima B.
    Reddy, Jayaprakash L.
    Kumar, Geetha P.
    Bhingraj, Mahmoud
    Chalmaji, Vecha
    Jaiswal, Priyesh
    Hanutej, A.
    Anne, Sandeep
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (69): : 14747 - 14757