Evaluation of the clinical performance of dentures manufactured by computer-aided technology and conventional techniques: A systematic review

被引:7
|
作者
Chocano, Ana Paula Chappuis [1 ]
Venante, Helena Sandrini [1 ,3 ]
da Costa, Rodrigo Moreira Bringel [1 ]
Pordeus, Mariana Domingues [1 ]
Santiago Junior, Joel Ferreira [2 ]
Porto, Vinicius Carvalho [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Bauru, Dept Periodont & Prosthodont, FOB USP, Bauru, SP, Brazil
[2] Sagrado Coracao Univ, Dept Hlth Sci, USC, Bauru, SP, Brazil
[3] Univ Sao Paulo, Dent Sch Bauru, Dept Periodont & Prosthodont, Al Octavio Pinheiro Brisola 9-75, BR-17012901 Bauru, SP, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 129卷 / 04期
关键词
CAD/CAM TECHNOLOGY; CAD-CAM; FABRICATION; ADAPTATION; RETENTION; ADHESIVES; MAXILLARY; IMPLANTS; BASES;
D O I
10.1016/j.prosdent.2021.06.029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The introduction of computer-aided design and computer-aided manufacturing (CAD-CAM) technology for complete denture fabrication may have improved clinical outcomes compared with conventional techniques. However, systematic reviews comparing these techniques are lacking.Purpose. The purpose of this systematic review was to identify, compare, and synthesize the outcomes of published clinical studies related to complete denture fabrication, with respect to the differences between CAD-CAM technology and conventional techniques.Material and methods. A comprehensive search of studies published up to March 16, 2020, was conducted by using the PubMed/MEDLINE, Web of Science, Cochrane Library, SciELO, and Embase databases according to the Preferred Reporting Items for Systematic Reviews and Meta -Analyses (PRISMA) statement criteria and was registered in the International Prospective Register of Systematic Reviews (PROSPERO ID 42020202614). The population, intervention, comparison, and outcome (PICO) question was: Do CAD-CAM complete dentures have a similar functional performance to those fabricated by conventional techniques? The quality of publications was appraised by using the Critical Appraisal Skills Program (CASP) checklists.Results. Of the 1232 titles, 6 articles were selected. The studies reported better retention of digitally manufactured complete dentures without denture adhesives than that of conventional complete dentures with or without denture adhesives. Other studies reported that dentures manufactured with digital systems were better adapted to tissue surfaces, required less clinical time, were lower in cost, and provided better experience and satisfaction to patients.Conclusions. The assessment of CAD-CAM planning and manufacturing through clinical studies is ongoing. However, preliminary results indicate better clinical performance and lower overall costs of digital complete dentures than conventional dentures. (J Prosthet Dent 2023;129:547-53)
引用
收藏
页码:547 / 553
页数:7
相关论文
共 50 条
  • [11] APPLICATION OF COMPUTER-AIDED EVALUATION FOR HOLOGRAPHY AND SIMILAR TECHNIQUES
    STEINBICHLER, H
    ENGELSBERGER, J
    SIXT, W
    SUN, J
    FRANZ, T
    OPTICS AND LASERS IN ENGINEERING, 1990, 13 (01) : 39 - 50
  • [12] A Review of Computer-Aided Heart Sound Detection Techniques
    Li, Suyi
    Li, Feng
    Tang, Shijie
    Xiong, Wenji
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [13] COMPUTER-AIDED PLANNING AND PERFORMANCE EVALUATION IN ORGANIZATIONS
    ARAKELOVA, ZN
    RYKOV, AS
    YAVORSKII, VV
    AUTOMATION AND REMOTE CONTROL, 1989, 50 (06) : 777 - 785
  • [14] COMPUTER-AIDED TECHNIQUES IN FOOD-TECHNOLOGY - SAGUY,I
    SWARTZEL, KR
    FOOD TECHNOLOGY, 1983, 37 (12) : 111 - 111
  • [15] Review of Research on Computer-Aided Deflectometric Measurement Technology
    Wu Zhendong
    Wang Daodang
    Ruan Yang
    Liang Rongguang
    ACTA OPTICA SINICA, 2022, 42 (17)
  • [16] Computer-aided diagnosis of headache disorders: A systematic review
    Deorari, Vaibhav
    Chowdhury, Debashish
    CEPHALALGIA, 2022, 42 (1_SUPPL) : 72 - 73
  • [17] Computer-Aided Systematic Review Screening Comes of Age
    Hemens, Brian J.
    Iorio, Alfonso
    ANNALS OF INTERNAL MEDICINE, 2017, 167 (03) : 210 - +
  • [18] Information and Communication Technology Application in Healthcare with Computer-Aided Design of Immediate Partial Dentures
    Dovramadjiev, Tihomir
    Pavlova, Diana
    Radeva, Julia
    ADVANCES IN HUMAN FACTORS AND ERGONOMICS IN HEALTHCARE AND MEDICAL DEVICES (AHFE 2021), 2021, 263 : 203 - 210
  • [19] Computer Engineering Complete Dentures Workflow: Systematic Techniques Review
    Al Moaleem, Mohammed M.
    Al-layl, Omaima A.
    Alhomood, Manar A.
    Ageeli, Walaa A.
    Qsadi, Alzhouor A.
    Mohammed, Tahani I. M.
    Baraqt, Emtinan S.
    Zubayni, Bashayr M. A.
    Alalmaie, Nada I.
    Huraysi, Ahmed H. M.
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (53A) : 207 - 220
  • [20] Performance evaluation of computer-aided automated master frame selection techniques for fetal echocardiography
    Sriraam, N.
    Punyaprabha, V
    Sushma, T., V
    Suresh, S.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2023, 61 (07) : 1723 - 1744