Energy performance and thermal comfort of integrated energy recovery ventilator system with air-conditioner for passive buildings

被引:5
|
作者
Cho, Wonhee [1 ]
Heo, Juneyeong [1 ]
Park, Myeong Hyeon [1 ]
Seo, Hyeong Joon [2 ]
Lee, Kisup [2 ]
Lee, Dong Gyu [2 ]
Kim, Yongchan [1 ]
机构
[1] Korea Univ, Dept Mech Engn, Anam Ro 145, Seoul 02841, South Korea
[2] Samsung Elect Co Ltd, Samsung Ro 129, Suwon 16677, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Energy recovery ventilator; Air conditioner; Thermal comfort; Energy efficiency; Dehumidification; SOUTH; HEAT;
D O I
10.1016/j.enbuild.2023.113302
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to provide a ventilation solution for energy-efficient buildings that suffer from high indoor moisture content during cooling seasons. With the decreased sensible load in highly insulated buildings, con-ventional energy recovery ventilators (ERVs) and air conditioners are inadequate to effectively handle the increased dehumidification load. Moisture removal through air conditioners requires cooling the air below its dew point, which makes precise control of indoor humidity difficult and reduces the level of indoor thermal comfort. Thus, an ERV system integrated with a cooling coil (ERV-CC) is proposed to enhance its latent heat effectiveness. Field measurements were conducted for the ERV and ERV-CC systems to compare their energy performances and levels of indoor thermal comfort. The results indicated that the ERV system did not satisfy the recommended range of indoor humidity even when the set-point temperature of the air conditioner decreased. However, the ERV-CC system could condition the indoor air within the comfort zone at higher energy effi-ciencies. In addition, the ERV-CC system was observed to benefit from the dehumidification effect through the enthalpy recovery process under a wider range of outdoor conditions. Especially, at low outdoor temperatures, the ERV-CC system dehumidified the incoming fresh air, whereas the ERV system humidified the fresh air. Overall, the optimum operating conditions for the ERV-CC system were determined to be a set-point temperature and relative humidity of 27 degrees C and 50%, respectively, while satisfying the thermal comfort criterion at an 8.24% predicted percentage dissatisfied index with minimum energy consumption. Furthermore, the ERV-CC system not only reduced the building load, but also improved the individual air conditioner performance.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Study on phase change material thermal characteristics during air charging/discharging for energy saving of air-conditioner
    Songheng Loem
    Thoranis Deethayat
    Attakorn Asanakham
    Tanongkiat Kiatsiriroat
    Heat and Mass Transfer, 2020, 56 : 2121 - 2133
  • [22] Air Conditioning System Integrated with Thermal Energy Storage for Buildings in Tropical Climates
    Santos, Alex
    Duarte, Willian
    Barbieri, Paulo
    Machado, Luiz
    Xu, Tianhao
    Paulino, Tiago
    Processes, 2024, 12 (11)
  • [23] Thermal comfort and indoor air quality in the lecture room with 4-way cassette air-conditioner and mixing ventilation system
    Noh, Kwang-Chul
    Jang, Jae-Soo
    Oh, Myung-Do
    BUILDING AND ENVIRONMENT, 2007, 42 (02) : 689 - 698
  • [24] Thermal Comfort in Zero Energy Buildings
    Pomfret, Laura
    Hashemi, Arman
    SUSTAINABILITY IN ENERGY AND BUILDINGS 2017, 2017, 134 : 825 - 834
  • [25] Study on phase change material thermal characteristics during air charging/discharging for energy saving of air-conditioner
    Loem, Songheng
    Deethayat, Thoranis
    Asanakham, Attakorn
    Kiatsiriroat, Tanongkiat
    HEAT AND MASS TRANSFER, 2020, 56 (07) : 2121 - 2133
  • [26] The effect of air-conditioner operation modes on the energy-saving capacity of external wall insulation in residential buildings
    Deng, Qinli
    Liu, Daoru
    Zhou, Zeng
    Ma, Sha
    ENERGY EXPLORATION & EXPLOITATION, 2021, 39 (02) : 620 - 636
  • [27] Effect of external air-conditioner units′ heat release modes and positions on energy consumption in large public buildings
    Han, Mengtao
    Chen, Hong
    BUILDING AND ENVIRONMENT, 2017, 111 : 47 - 60
  • [28] Renewable Energy Source Allocation of Air-Conditioner Using Fuzzy Logic
    Rao, M. Nageswara
    Ravindra, K.
    Chaitanya, V. S. N. K.
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL (I2C2), 2017,
  • [29] Experimental Study of Energy-Saving Air-Conditioner with Hot Water
    CHEN Jian-bo
    CHEN Dan
    LU Ying(University of Shanghai for Science and Technology
    Shanghai
    China)
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 75 - 78
  • [30] Energy reduction of building air-conditioner with phase change material in Thailand
    Chaiyat, Nattaporn
    Kiatsiriroat, Tanongkiat
    CASE STUDIES IN THERMAL ENGINEERING, 2014, 4 : 175 - 186