Thermal performance analysis of artificially roughened solar air heater under turbulent pulsating flow with various wave shapes

被引:7
|
作者
Farouk, Naeim [1 ,2 ]
Abed, Azher M. [3 ]
Singh, Pradeep Kumar [4 ]
Ali, H. Elhosiny [5 ,6 ,7 ]
Alshuraiaan, Bader [8 ]
Nguyen, Van Giao [9 ]
Wae-hayee, Makatar [10 ]
Nguyen, Dinh Tuyen [11 ]
El Bouz, M. A. [12 ]
机构
[1] Prince Sattam Bin Abdulaziz Univ, Coll Engn Alkharj, Dept Mech Engn, Al Kharj 11942, Saudi Arabia
[2] Red Sea Univ, Coll Engn Port Sudan, Dept Mech Engn, Port Sudan 33311, Sudan
[3] Al Mustaqbal Univ Coll, Air Conditioning & Refrigerat Tech Engn Dept, Babylon 51001, Iraq
[4] GLA Univ, Inst Engn & Technol, Dept Mech Engn, Mathura 281406, UP, India
[5] King Khalid Univ, Fac Sci, Dept Phys, POB 9004, Abha, Saudi Arabia
[6] King Khalid Univ, Res Ctr Adv Mat Sci RCAMS, POB 9004, Abha 61413, Saudi Arabia
[7] Zagazig Univ, Fac Sci, Phys Dept, Zagazig 44519, Egypt
[8] Kuwait Univ, Dept Mech Engn, Safat 13060, Kuwait
[9] HUTECH Univ, Inst Engn, Ho Chi Minh City, Vietnam
[10] Prince Songkla Univ, Fac Engn, Dept Mech & Mechatron Engn, Hat Yai 90110, Songkhla, Thailand
[11] Ho Chi Minh City Univ Transport, PATET Res Grp, Ho Chi Minh City, Vietnam
[12] Mansoura Univ, Fac Engn, Mech Power Engn Dept, Mansoura, Egypt
关键词
Turbulent pulsating flow; Thermo-hydraulic performance parameter; (THPP); Artificial roughness; RNG k-? turbulence Model; THERMOHYDRAULIC PERFORMANCE; TRANSFER ENHANCEMENT; NANOFLUID FLOW; RIB ROUGHNESS; CHANNEL; FIN;
D O I
10.1016/j.csite.2022.102664
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a numerical investigation of the operation of a solar air heater (SAH) with cylindrical shape ribs under turbulent pulsating flow based on thermal and frictional consider-ations. Turbulence and thermal natures of flow physics are modeled by taking the relevant governing equations into the account using RNG k -epsilon turbulence model and transient state Reynolds-Averaged Navier-Stokes (RANS) equations. The pulsating flow is modeled with four different wave shapes including rectangular, sinusoidal, triangular, and sawtooth functions. The influence of various factors such as wave shape, Reynolds number (Re), frequency, and amplitude of pulsating flow on the thermal and hydraulic performance of SAH has been evaluated. Results indicated that the SAH with ribbed absorber section under pulsed flow has a larger Nu number compared to the air heater with smooth duct under steady flow. Moreover, the pulsating flow with a sawtooth velocity profile leads to the greatest value of the thermo-hydraulic performance parameter (THPP). The growth of pulsation frequency up to 200 enhances the heat transfer co-efficient of the air heater while for frequencies larger than 200, the thermal performance declines. In addition, the increase in pulsation amplitude has a negative effect on the THPP. It was proved that the increment of the Re number enhances the THPP. Up to 53.3% improvement of THPP can be achieved by applying pulsed flow with sawtooth wave shape and ribbed absorber section compared to air heat with smooth duct under steady flow.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Effect of heat transfer and pressure drop characteristics on the performance analysis of an artificially roughened solar air heater
    Kumar, Amit
    Layek, Apurba
    HEAT AND MASS TRANSFER, 2023, 59 (05) : 891 - 907
  • [12] The Effect of Flow Obstacles of Different Shapes for Generating Turbulent Flow for Improved Performance of the Solar Air Heater
    Sharma, N. Yagnesh
    Madhwesh, N.
    Karanth, K. Vasudeva
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS PROCESSING AND MANUFACTURING (SMPM 2019), 2019, 35 : 1096 - 1101
  • [13] Performance of Solar Air Heater Having Absorber Plate Roughened with Protrusions of Different Shapes
    Soi, Aman
    Singh, Ranjit
    Bhushan, Brij
    PROCEEDINGS OF 2019 IEEE 2ND INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY AND POWER ENGINEERING (REPE 2019), 2019, : 177 - 181
  • [14] Thermal analysis of three sides artificially roughened solar air heaters
    Behura, Arun Kumar
    Rout, Sachindra Kumar
    Pandya, Himanshu
    Kumar, Ashiwini
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 279 - 285
  • [15] Fluid flow and heat transfer analysis for heat transfer enhancement in three sided artificially roughened solar air heater
    Prasad, B. N.
    Behura, Arun K.
    Prasad, L.
    SOLAR ENERGY, 2014, 105 : 27 - 35
  • [16] Evaluation of thermal performance factor for solar air heaters with artificially roughened channels
    Siddique, Waseem
    Raheem, Aneeq
    Aqeel, Muhammad
    Qayyum, Sualeh
    Salamen, Tareq
    Waheed, Khalid
    Qureshi, Kamran
    ARCHIVE OF MECHANICAL ENGINEERING, 2021, 68 (02) : 195 - 225
  • [17] A REVIEW OF THE THERMAL AND HYDRODYNAMIC PERFORMANCE OF SOLAR AIR HEATER WITH ROUGHENED ABSORBER PLATES
    Sahu, Mukesh Kumar
    Prasad, Radha Krishna
    JOURNAL OF ENHANCED HEAT TRANSFER, 2016, 23 (01) : 47 - 89
  • [18] Performance analysis of roughened triangular solar air heater for preheating applications
    Stalin, P. Michael Joseph
    Sivamaran, V.
    Lokanadham, R.
    Kavimani, V.
    Mandal, T. K.
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2024, 18 (07): : 4647 - 4659
  • [19] Experimental investigations of thermal performance for flat and dimpled plate solar air heater under turbulent flow conditions
    Bhushan, Abhishek
    Kumar, Rakesh
    Perwez, Ashif
    SOLAR ENERGY, 2022, 231 : 664 - 683
  • [20] Field synergy analysis for turbulent heat transfer on ribs roughened solar air heater
    Hamid, Mohammed O. A.
    Zhang, Bo
    RENEWABLE ENERGY, 2015, 83 : 1007 - 1019