Purpose: To assess the reliability and minimal detectable change (MDC) of weight-bearing asymmetry (WBA) and body sway (BS) during "eyes open" (EO) and "eyes closed" (EC) conditions for those with right brain damage (RBD) and left brain damage (LBD) at a chronic stage. Methods: Sixteen RBD and 16 LBD patients participated in two sessions within 15 days, composed of two trials of 30s using a double force platform. Intraclass correlation coefficient (ICC2,1), the standard error of measurement (SEM), and MDC were calculated for WBA and BS (area and velocity of sway). Results: Reliability of WBA was excellent (>0.75) except for EC for LBD patients (low SEM was found). The condition of EC was similar to or less reliable than that of EO. The MDC of WBA was 5.4 and 7.3% for LBD and RBD patients, respectively. Velocity of sway should be favored over the area of sway due to better reliability, with an MDC of 9 and 13 mm/s for RBD and LBD patients, respectively. Conclusions: Parameters related to WBA and BS were highly reliable, without a difference between RBD and LBD patients, but less so in the condition of EC, and could be used for clinical rehabilitation and/or research.