Study on the carbon footprint of cold storage units using low-GWP alternative refrigerants

被引:2
|
作者
Gong, Li [1 ]
Zhang, Zhongbin [1 ]
Chen, Meng [1 ]
Taylor, Steve [2 ]
Wang, Xiaolin [3 ]
机构
[1] Nanjing Normal Univ, Sch Energy & Mech Engn, Nanjing 210046, Jiangsu, Peoples R China
[2] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, England
[3] Australian Natl Univ, Sch Engn, Canberra, ACT 2601, Australia
关键词
Cold storage unit; Low-GWP; R448A; Carbon footprint; PERFORMANCE ANALYSIS; ENERGY-CONSUMPTION; R404A; OPTIMIZATION; SYSTEMS; R134A; RETROFIT; R513A; CYCLE;
D O I
10.1016/j.jclepro.2023.139589
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The increasing contribution of refrigeration systems to global warming has led to widespread demand for low global warming potential (GWP) refrigerants as alternatives. This paper proposed a comprehensive environ-mental assessment method for evaluating the carbon footprint of units charged with low-GWP refrigeration. Experimental and numerical studies were used to investigate the carbon footprint impact of using alternative refrigerants at different ambient temperatures in China. Initially, the model was validated through experimental case studies on the use stage of cold storage units. Subsequently, a comparison was made between the cooling capacity (CC) and energy efficiency ratio (EER) of cold storage units charged with different refrigerants. Addi-tionally, the impact of alternative refrigerants in the use stage was analyzed by numerical calculations, and the adaptability of the cold storage unit to the ambient temperature and the national energy structure was also studied. The results indicate that among the four stages of the cold storage unit, the use stage is the hotspot of carbon footprint due to the large amount of energy consumption and the existence of refrigerant leakage and other behaviors. Utilizing low-GWP alternative refrigerants could significantly reduce the carbon footprint of the cold storage units' use stage by 10.56%-16.39%, thereby lowering the whole stage carbon footprint. Further-more, the ambient temperature and national energy structure could also effectively reduce the carbon footprint of cold storage units' whole stage by 1%-27.17%. Furthermore, after adopting low GWP refrigerants, the life-cycle cost (LCC) of the units have also decreased by 6.1%-12%. Taking into account both environmental impact and economic considerations, it is recommended to directly replace R404A with R448A in the units in regions where the average ambient temperature is above 15 degrees C.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Development of a light-commercial compressor load stand to measure compressor performance using low-GWP refrigerants
    Schmidt, Drew
    Singleton, Jake
    Bradshaw, Craig R.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 443 - 453
  • [42] Thermal-economic-environmental analysis on household refrigerator using a variable displacement compressor and low-GWP refrigerants
    Zhu, Zhennan
    Liang, Kun
    Li, Zhaohua
    Jiang, Hanying
    Meng, Zhongwei
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 123 : 189 - 197
  • [43] Energy, exergy and economic optimization of a two-stage refrigeration system using low-GWP alternative refrigerants for high-temperature lift applications
    Roy, Ranendra
    Mandal, Bijan Kumar
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (08)
  • [44] Marine refrigeration plants for passenger ships: Low-GWP refrigerants and strategies to reduce environmental impact
    Pigani, Lorenzo
    Boscolo, Marco
    Pagan, Nicola
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2016, 64 : 80 - 92
  • [45] An analysis on the comparison of low-GWP refrigerants to alternatively use in mobile air-conditioning systems
    Devecioglu, Atilla G.
    Oruc, Vedat
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2017, 1 : 1 - 5
  • [46] Energy, exergy and economic optimization of a two-stage refrigeration system using low-GWP alternative refrigerants for high-temperature lift applications
    Ranendra Roy
    Bijan Kumar Mandal
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [47] APPLICATION OF DYNAMIC BUBBLE DEPARTURE MODEL FOR NEW, LOW-GWP REFRIGERANTS ON ENHANCED, STRUCTURED SURFACES
    Shaligram, Avinash
    Saha, Sandip Kumar
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017 VOL 8, 2018,
  • [48] Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration
    Muneeshwaran, M.
    Yang, Cheng-Min
    Cakmak, Ercan
    Nawaz, Kashif
    [J]. APPLIED THERMAL ENGINEERING, 2024, 248
  • [49] Development of New Low-GWP Refrigerants-Refrigerant Mixtures Including HFO-1123
    Hashimoto, Mai
    Otsuka, Tetsuo
    Fukushima, Masato
    Okamoto, Hidekazu
    Hayamizu, Hiroki
    Ueno, Katsuya
    Akasaka, Ryo
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (06) : 776 - 783
  • [50] Multi-Objective Optimization of a Small-Scale ORC-VCC System Using Low-GWP Refrigerants
    Witanowski, Lukasz
    [J]. Energies, 2024, 17 (21)