Study on the carbon footprint of cold storage units using low-GWP alternative refrigerants

被引:2
|
作者
Gong, Li [1 ]
Zhang, Zhongbin [1 ]
Chen, Meng [1 ]
Taylor, Steve [2 ]
Wang, Xiaolin [3 ]
机构
[1] Nanjing Normal Univ, Sch Energy & Mech Engn, Nanjing 210046, Jiangsu, Peoples R China
[2] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, England
[3] Australian Natl Univ, Sch Engn, Canberra, ACT 2601, Australia
关键词
Cold storage unit; Low-GWP; R448A; Carbon footprint; PERFORMANCE ANALYSIS; ENERGY-CONSUMPTION; R404A; OPTIMIZATION; SYSTEMS; R134A; RETROFIT; R513A; CYCLE;
D O I
10.1016/j.jclepro.2023.139589
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The increasing contribution of refrigeration systems to global warming has led to widespread demand for low global warming potential (GWP) refrigerants as alternatives. This paper proposed a comprehensive environ-mental assessment method for evaluating the carbon footprint of units charged with low-GWP refrigeration. Experimental and numerical studies were used to investigate the carbon footprint impact of using alternative refrigerants at different ambient temperatures in China. Initially, the model was validated through experimental case studies on the use stage of cold storage units. Subsequently, a comparison was made between the cooling capacity (CC) and energy efficiency ratio (EER) of cold storage units charged with different refrigerants. Addi-tionally, the impact of alternative refrigerants in the use stage was analyzed by numerical calculations, and the adaptability of the cold storage unit to the ambient temperature and the national energy structure was also studied. The results indicate that among the four stages of the cold storage unit, the use stage is the hotspot of carbon footprint due to the large amount of energy consumption and the existence of refrigerant leakage and other behaviors. Utilizing low-GWP alternative refrigerants could significantly reduce the carbon footprint of the cold storage units' use stage by 10.56%-16.39%, thereby lowering the whole stage carbon footprint. Further-more, the ambient temperature and national energy structure could also effectively reduce the carbon footprint of cold storage units' whole stage by 1%-27.17%. Furthermore, after adopting low GWP refrigerants, the life-cycle cost (LCC) of the units have also decreased by 6.1%-12%. Taking into account both environmental impact and economic considerations, it is recommended to directly replace R404A with R448A in the units in regions where the average ambient temperature is above 15 degrees C.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Low-GWP refrigerants
    Brown, J. Steven
    Zilio, Claudio
    Akasaka, Ryo
    Higashi, Yukihiro
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (08) : 1075 - 1076
  • [2] Test Results of Low-GWP Alternative Refrigerants for Refrigeration Applications
    Wang, Xudong
    Amrane, Karim
    [J]. 2013 ASHRAE ANNUAL CONFERENCE, 2013,
  • [3] DuPont tests Low-GWP refrigerants
    不详
    [J]. ASHRAE JOURNAL, 2006, 48 (05) : 8 - 8
  • [4] Thermodynamic and Environmental Assessment of Low-GWP Alternative Refrigerants for Domestic Cooling
    Islam M.A.
    Rupam T.H.
    Hosan S.
    Saha B.B.
    [J]. Journal of The Institution of Engineers (India): Series C, 2023, 104 (02) : 377 - 383
  • [5] A thermodynamic analysis of refrigerants: Possibilities and tradeoffs for Low-GWP refrigerants
    McLinden, Mark O.
    Kazakov, Andrei F.
    Brown, J. Steven
    Domanski, Piotr A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 38 : 80 - 92
  • [6] Low-GWP refrigerants for medium and highpressure applications
    Domanski, Piotr A.
    Brignoli, Riccardo
    Brown, J. Steven
    Kazakov, Andrei F.
    McLinden, Mark O.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 : 198 - 209
  • [7] DISPROPORTIONATION RISK STUDY FOR TRIFLUOROETHYLENE COMPOSITION AS LOW-GWP REFRIGERANTS
    Okamoto, Hidekazu
    Otsuka, Tetsuo
    Hayamizu, Hiroki
    Ueno, Katsuya
    Fukushima, Masato
    Ippommatsu, Masamichi
    [J]. 1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 211 - 217
  • [8] Techno-economic and environmental analysis of low-GWP alternative refrigerants in cold storage unit under year-round working conditions
    Gao, Enyuan
    Zhang, Zhongbin
    Deng, Qingqing
    Jing, Huaqian
    Wang, Xiaolin
    Zhang, Xiaosong
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 134 : 197 - 206
  • [9] LOW-GWP REFRIGERANTS: PERFORMANCE ASSESSMENT AND SELECTION TRADEOFFS
    Domanski, Piotr A.
    Brignoli, Riccardo
    Brown, J. Steven
    Kazakov, Andrei F.
    McLinden, Mark O.
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 21 - 32
  • [10] 1,200 Low-GWP Refrigerants Identified
    不详
    [J]. ASHRAE JOURNAL, 2012, 54 (11) : 10 - 10