Spatial resolution, noise properties, and detectability index of a deep learning reconstruction algorithm for dual-energy CT of the abdomen

被引:6
|
作者
Thor, Daniel [1 ,2 ]
Titternes, Rebecca [1 ,3 ]
Poludniowski, Gavin [1 ,3 ,4 ]
机构
[1] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
[2] Karolinska Inst, Dept Oncol Pathol, Stockholm, Sweden
[3] Karolinska Inst, Dept Clin Sci Intervent & Technol, Stockholm, Sweden
[4] Karolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
关键词
DECT; deep learning image reconstruction; image quality; FILTERED BACK-PROJECTION; RADIATION-DOSE REDUCTION; ITERATIVE RECONSTRUCTION; IMAGE-RECONSTRUCTION; PERFORMANCE; CONTRAST; OPTIMIZATION;
D O I
10.1002/mp.16300
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundIterative reconstruction (IR) has increasingly replaced traditional reconstruction methods in computed tomography (CT). The next paradigm shift in image reconstruction is likely to come from artificial intelligence, with deep learning reconstruction (DLR) solutions already entering the clinic. An enduring disadvantage to IR has been a change in noise texture, which can affect diagnostic confidence. DLR has demonstrated the potential to overcome this issue and has recently become available for dual-energy CT. PurposeTo evaluate the spatial resolution, noise properties, and detectability index of a commercially available DLR algorithm for dual-energy CT of the abdomen and compare it to single-energy (SE) CT. MethodsAn oval 25 cm x 35 cm custom-made phantom was scanned on a GE Revolution CT scanner (GE Healthcare, Waukesha, WI) at two dose levels (13 and 5 mGy) and two iodine concentrations (8 and 2 mg/mL), using three typical abdominal scan protocols: dual-energy (DE), SE 80 kV (SE-80 kV) and SE 120 kV (SE-120 kV). Reconstructions were performed with three strengths of IR (ASiR-V: AR0%, AR50%, AR100%) and three strengths of DLR (TrueFidelity: low, medium, high). The DE acquisitions were reconstructed as mono-energetic images between 40 and 80 keV. The noise power spectrum (NPS), task transfer function (TTF), and detectability index (d') were determined for the reconstructions following the recommendations of AAPM Task Group 233. ResultsNoise magnitude reductions (relative to AR0%) for the SE protocols were on average (-29%, -21%) for (AR50%, TF-M), while for DE-70 keV were (-28%, -43%). There was less reduction in mean frequency (f(av)) for DLR than for IR, with similar results for SE and DE imaging. There was, however, a substantial change in the NPS shape when using DE with DLR, quantifiable by a marked reduction in the peak frequency (f(peak)) that was absent in SE mode. All protocols and reconstructions (including AR0%) exhibited slight to moderate shifts towards lower spatial frequencies at the lower dose (<12% in f(av)). Spatial resolution was consistently superior for DLR compared to IR for SE but not for DE. All protocols and reconstructions (including AR0%) showed decreased resolution with reduced dose and iodine concentration, with less decrease for DLR compared to IR. DLR displayed a higher d' than IR. The effect of energy was large: d' increased with lower keV, and SE-80 kV had higher d' than SE-120 kV. Using DE with DLR could provide higher d' than SE-80 kV at the higher dose but not at lower dose. ConclusionsDE imaging with DLR maintained spatial resolution and reduced noise magnitude while displaying less change in noise texture than IR. The d' was also higher with DLR than IR, suggesting superiority in detectability of iodinated contrast. Despite these trends being consistent with those previously established for SE imaging, there were some noteworthy differences. For DE imaging there was no improvement in resolution compared to IR and a change in noise texture. DE imaging with low keV and DLR had superior detectability to SE DLR at the high dose but was not better than SE-80 kV at low dose.
引用
收藏
页码:2775 / 2786
页数:12
相关论文
共 50 条
  • [31] Pseudo low-energy monochromatic imaging of head and neck cancers: Deep learning image reconstruction with dual-energy CT
    Koike, Yuhei
    Ohira, Shingo
    Teraoka, Yuri
    Matsumi, Ayako
    Imai, Yasuhiro
    Akino, Yuichi
    Miyazaki, Masayoshi
    Nakamura, Satoaki
    Konishi, Koji
    Tanigawa, Noboru
    Ogawa, Kazuhiko
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (07) : 1271 - 1279
  • [32] Noise Subtraction for Dual-Energy CT Images Using A Deep Convolutional Neural Network
    Missert, A.
    Yu, L.
    Leng, S.
    McCollough, C.
    MEDICAL PHYSICS, 2019, 46 (06) : E408 - E409
  • [33] Deep Learning Electronic Cleansing for Single- and Dual-Energy CT Colonography
    Tachibana, Rie
    Nappi, Janne J.
    Ota, Junko
    Kohlhase, Nadja
    Hironaka, Toru
    Kim, Se Hyung
    Regge, Daniele
    Yoshida, Hiroyuki
    RADIOGRAPHICS, 2018, 38 (07) : 2034 - 2050
  • [34] Improving lesion conspicuity in abdominal dual-energy CT with deep learning image reconstruction: a prospective study with five readers
    Jingyu Zhong
    Lingyun Wang
    Hailin Shen
    Jianying Li
    Wei Lu
    Xiaomeng Shi
    Yue Xing
    Yangfan Hu
    Xiang Ge
    Defang Ding
    Fuhua Yan
    Lianjun Du
    Weiwu Yao
    Huan Zhang
    European Radiology, 2023, 33 : 5331 - 5343
  • [35] Single-Subject Deep-Learning Image Reconstruction With a Neural Optimization Transfer Algorithm for PET-Enabled Dual-Energy CT Imaging
    Li, Siqi
    Zhu, Yansong
    Spencer, Benjamin A.
    Wang, Guobao
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2024, 33 : 4075 - 4089
  • [36] Deep-learning reconstruction enhances image quality of Adamkiewicz Artery in low-keV dual-energy CT
    Tatsugami, Fuminari
    Higaki, Toru
    Kawashita, Ikuo
    Fujioka, Chikako
    Nakamura, Yuko
    Takahashi, Shinya
    Awai, Kazuo
    ACTA RADIOLOGICA, 2024, : 1569 - 1575
  • [37] Quantitative and qualitative assessments of deep learning image reconstruction in low-keV virtual monoenergetic dual-energy CT
    Jack Junchi Xu
    Lars Lönn
    Esben Budtz-Jørgensen
    Kristoffer L. Hansen
    Peter S. Ulriksen
    European Radiology, 2022, 32 : 7098 - 7107
  • [38] Improving lesion conspicuity in abdominal dual-energy CT with deep learning image reconstruction: a prospective study with five readers
    Zhong, Jingyu
    Wang, Lingyun
    Shen, Hailin
    Li, Jianying
    Lu, Wei
    Shi, Xiaomeng
    Xing, Yue
    Hu, Yangfan
    Ge, Xiang
    Ding, Defang
    Yan, Fuhua
    Du, Lianjun
    Yao, Weiwu
    Zhang, Huan
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5331 - 5343
  • [39] Quantitative and qualitative assessments of deep learning image reconstruction in low-keV virtual monoenergetic dual-energy CT
    Xu, Jack Junchi
    Lonn, Lars
    Budtz-Jorgensen, Esben
    Hansen, Kristoffer L.
    Ulriksen, Peter S.
    EUROPEAN RADIOLOGY, 2022, 32 (10) : 7098 - 7107
  • [40] Reducing radiation dose in routine CT scans: an AI-driven approach with deep learning–based dual-energy CT reconstruction
    Enming Cui
    European Radiology, 2024, 34 : 26 - 27