Assessing the robustness of muscle strength and physical performance measures in women older than 40 years: a test-retest reliability study

被引:0
|
作者
Silva, Sebastiao Henrique Assis [1 ]
Orsatti, Fabio L. [1 ,2 ]
de Lima, Mariana L. [1 ]
de Freitas, Augusto C. Q. [1 ]
Carneiro, Marcelo A. S. [1 ]
Assumpcao, Claudio de Oliveira [1 ,2 ]
Souza, Markus Vinicius C. [1 ,2 ,3 ]
机构
[1] Univ Fed Triangulo Mineiro, Exercise Biol & Aging Lab BioEx, Appl Physiol Nutr & Exercise Res Grp, Uberaba, MG, Brazil
[2] Univ Fed Triangulo Mineiro, Hlth Sci Inst, Dept Sport Sci, Uberaba, MG, Brazil
[3] Univ Fed Triangulo Mineiro, Exercise Biol & Aging Lab BioEx, Appl Physiol Nutr & Exercise Res Grp, Ave Frei Paulino 30, BR-38025180 Uberaba, MG, Brazil
来源
MENOPAUSE-THE JOURNAL OF THE MENOPAUSE SOCIETY | 2024年 / 31卷 / 01期
关键词
One-repetition maximum; Physical function-Test-retest reliability; Women; HEALTH;
D O I
10.1097/GME.0000000000002294
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
This study investigated the test-retest reliability and minimal detectable change of muscle strength and physical performance tests in women aged over 40 years. ObjectivesThis study investigated the test-retest reliability and minimal detectable change (MDC) of muscle strength and physical performance tests in women older than 40 years.MethodsA total of 113 women, aged 58 +/- 11 years (82% postmenopausal women), with a body mass index of 28.5 +/- 5.8 kg/m2, participated in this study. One-repetition maximum (1RM) tests were conducted for seven strength exercises: 45 degrees leg press, bench press, leg extension, pec deck, wide-grip lateral pull-down, leg curl, and seated cable row, with a retest after 48 hours. Timed Up and Go (TUG), 6-minute walk, and 30-second sit-to-stand tests were performed on the same day and retested after 72 hours. The tests and retests were administered by the same evaluators. Relative reliability (consistency of participant rank between test-retest) was assessed using the intraclass correlation coefficient for consistency and agreement, and absolute reliability (precision of score) was assessed using the MDC based on the standard error of prediction.ResultsThe 1RM and performance tests exhibited excellent reliability: 45 degrees leg press (consistency, 0.99; agreement, 0.98), bench press (consistency, 0.96; agreement, 0.96), leg extension (consistency, 0.93; agreement, 0.91), pec deck (consistency, 0.90; agreement, 0.88), wide-grip lateral pull-down (consistency, 0.91; agreement, 0.89), leg curl (consistency, 0.84; agreement, 0.83), seated cable row (consistency, 0.92; agreement, 0.94), TUG (consistency, 0.87; agreement, 0.87), 6-minute walk (consistency, 0.96; agreement, 0.95), and 30-second sit to stand (consistency, 0.85; agreement, 0.80). These tests showed meaningful MDC values, particularly for the 1RM test performed on the machine and the 30-second sit-to-stand test: 45 degrees leg press, 22.2 kg (15%); bench press, 4.9 kg (19%); leg extension, 9.2 kg (35%); pec deck, 8.8 kg (44%); wide-grip lateral pull-down, 9.4 kg (31%); leg curl, 9.2 kg (51%); seated cable row, 11.4 kg (29%); TUG, 1.4 seconds (20%); 6-minute walk, 50.9 m (10%); and 30-second sit to stand, 4.6 reps (30%).ConclusionsAlthough the muscle strength and physical performance tests demonstrate excellent relative reliability in women older than 40 years, they exhibit low absolute reliability, particularly the 1RM test performed on the machine and the 30-second sit-to-stand test. Therefore, although these tests show good consistency in the positioning of women within the group after repeated measures, their precision measure is relatively low (high fluctuation). Changes in these tests that are smaller than the MDC may not indicate real changes in women at middle age and older.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [21] Test-Retest Reliability of Muscle Strength and Physical Function Tests in 6-9-Year-old Children
    Thams, L.
    Hvid, L. G.
    Damsgaard, C. T.
    Hansen, M.
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2021, 25 (04) : 379 - 387
  • [22] Test-Retest Reliability of the Women's Health Initiative Physical Activity Questionnaire
    Meyer, Anne-Marie
    Evenson, Kelly R.
    Morimoto, Libby
    Siscovick, David
    White, Emily
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2009, 41 (03): : 530 - 538
  • [23] Work-related measures of physical and behavioral health function: Test-retest reliability
    Marino, Molly Elizabeth
    Meterko, Mark
    Marfeo, Elizabeth E.
    McDonough, Christine M.
    Jette, Alan M.
    Ni, Pengsheng
    Bogusz, Kara
    Rasch, Elizabeth K.
    Brandt, Diane E.
    Chan, Leighton
    DISABILITY AND HEALTH JOURNAL, 2015, 8 (04) : 652 - 657
  • [24] Upper extremity physical performance tests in female overhead athletes: a test-retest reliability study
    Kardor, Sara
    Gorji, Zahra
    Ghotbi, Nastaran
    Attarbashi-Moghadam, Behrouz
    Shadmehr, Azadeh
    Gorji, Mona
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [25] TEST-RETEST RELIABILITY OF MAXIMAL LEG MUSCLE POWER AND FUNCTIONAL PERFORMANCE MEASURES IN PATIENTS WITH SEVERE OSTEOARTHRITIS (OA)
    Villadsen, A.
    Roos, E. M.
    Overgaard, S.
    Holsgaard-Larsen, A.
    OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S72 - S73
  • [26] Test-Retest Reliability of Common Measures of Eating Disorder Symptoms in Men Versus Women
    Forbush, Kelsie T.
    Hilderbrand, Lindsay A.
    Bohrer, Brittany K.
    Chapa, Danielle A. N.
    ASSESSMENT, 2019, 26 (03) : 419 - 431
  • [27] Test-retest reliability of measures of social network in the "Pro-Saude" Study
    Griep, RH
    Chor, D
    Faerstein, E
    Lopes, C
    REVISTA DE SAUDE PUBLICA, 2003, 37 (03): : 379 - 385
  • [28] Test-retest reliability of isometric shoulder muscle strength measurement with a handheld dynamometer and belt
    Katoh, Munenori
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (06) : 1719 - 1722
  • [29] Test-retest reliability of Latin American Group for Maturity (GDLAM) protocol in older women
    Ojeda, Alvaro Huerta
    Jofre-Saldia, Emilio
    Molina, Jimena Arriagada
    Quinchavil, Patricia Rojas
    Toledo, Maria Paz Parada
    Maliqueo, Sergio Galdames
    Yeomans-Cabrera, Maria-Mercedes
    Jorquera-Aguilera, Carlos
    Giakoni-Ramirez, Frano
    Bravo, Maximiliano
    PLOS ONE, 2024, 19 (04):
  • [30] Reproducibility of strength performance and strength-endurance profiles: A test-retest study
    Mitter, Benedikt
    Csapo, Robert
    Bauer, Pascal
    Tschan, Harald
    PLOS ONE, 2022, 17 (05):