Reliability and measurement error of sensorimotor tests in patients with neck pain: a systematic review

被引:3
|
作者
Elsig, Simone [1 ,2 ,3 ,4 ,5 ]
Allet, Lara [3 ,4 ,5 ,6 ]
Bastiaenen, Caroline Henrice Germaine [2 ]
de Bie, Rob [2 ]
Hilfiker, Roger [1 ]
机构
[1] Univ Appl Sci & Arts Western Switzerland, Sch Hlth Sci, HES SO Valais Wallis, Rathausstr 25, CH-3954 Leukerbad, Valais, Switzerland
[2] Maastricht Univ, CAPHRI Care & Publ Hlth Res Inst, Dept Epidemiol Res Line Functioning Participat & R, POB 616, NL-6200 Maastricht, Netherlands
[3] Univ Appl Sci & Arts Western Switzerland, Sch Hlth Sci, HES SO Valais Wallis, Chemin Agasse 5, Sion, Valais, Switzerland
[4] Sense Innovat & Res Ctr, Lausanne, Switzerland
[5] Sense Innovat & Res Ctr, Sion, Switzerland
[6] Univ Geneva, Fac Med, Dept Med, Geneva, Switzerland
关键词
Neck pain; Sensorimotor tests; Reliability; CERVICOCEPHALIC KINESTHETIC SENSIBILITY; EXTENSOR MUSCLE ENDURANCE; LOW-BACK-PAIN; CERVICAL RANGE; INTERRATER RELIABILITY; INTRARATER RELIABILITY; PHYSICAL-EXAMINATION; GENERAL-POPULATION; CLINICAL-TESTS; MOTION CROM;
D O I
10.1186/s40945-023-00170-9
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
BackgroundNeck pain is one of the leading causes of years lived with disability, and approximately half of people with neck pain experience recurrent episodes. Deficits in the sensorimotor system can persist even after pain relief, which may contribute to the chronic course of neck pain in some patients. Evaluation of sensorimotor capacities in patients with neck pain is therefore important. No consensus exists on how sensorimotor capacities of the neck should be assessed in physiotherapy. The aims of this systematic review are: (a) to provide an overview of tests used in physiotherapy for assessment of sensorimotor capacities in patients with neck pain; and (b) to provide information about reliability and measurement error of these tests, to enable physiotherapists to select appropriate tests.MethodsMedline, CINAHL, Embase and PsycINFO databases were searched for studies reporting data on the reliability and/or measurement error of sensorimotor tests in patients with neck pain. The results for reliability and measurement error were compared against the criteria for good measurement properties. The quality of evidence was assessed according to the modified GRADE method proposed by the COSMIN group.ResultsA total of 206 tests for assessment of sensorimotor capacities of the neck were identified and categorized into 18 groups of tests. The included tests did not cover all aspects of the sensorimotor system; tests for the sensory and motor components were identified, but not for the central integration component. Furthermore, no data were found on reliability or measurement error for some tests that are used in practice, such as movement control tests, which apply to the motor component. Approximately half of the tests showed good reliability, and 12 were rated as having good (+) reliability. However, tests that evaluated complex movements, which are more difficult to standardize, were less reliable. Measurement error could not be evaluated because the minimal clinically important change was not available for all tests.ConclusionOverall, the quality of evidence is not yet high enough to enable clear recommendations about which tests to use to assess the sensorimotor capacities of the neck.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] The reliability and measurement error of protractor-based goniometry of the fingers: A systematic review
    van Kooij, Yara E.
    Fink, Alexandra
    Nijhuis-van der Sanden, Maria W.
    Speksnijder, Caroline M.
    JOURNAL OF HAND THERAPY, 2017, 30 (04) : 457 - 467
  • [22] RELIABILITY AND MEASUREMENT ERROR OF TENSIOMYOGRAPHY TO ASSESS MECHANICAL MUSCLE FUNCTION: A SYSTEMATIC REVIEW
    Martin-Rodriguez, Saul
    Loturco, Irineu
    Hunter, Angus M.
    Rodriguez-Ruiz, David
    Munguia-Izquierdo, Diego
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (12) : 3524 - 3536
  • [23] Measures of neck muscle strength and their measurement properties in adults with chronic neck pain—a systematic review
    Deepa Abichandani
    Jonathan Tong Yuk Ting
    Edith Elgueta Cancino
    Shouq Althobaiti
    Deborah Falla
    Systematic Reviews, 12
  • [24] Sensorimotor Control in Individuals With Idiopathic Neck Pain and Healthy Individuals: A Systematic Review and Meta-Analysis
    de Zoete, Rutger M. J.
    Osmotherly, Peter G.
    Rivett, Darren A.
    Farrell, Scott F.
    Snodgrass, Suzanne J.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 98 (06): : 1257 - 1271
  • [25] What is the reliability of clinical measurement tests for humeral head position? A systematic review
    Konieczka, Christine
    Gibson, Christine
    Russett, Leeann
    Dlot, Leah
    MacDermid, Joy
    Watson, Lyn
    Sadi, Jackie
    JOURNAL OF HAND THERAPY, 2017, 30 (04) : 420 - 431
  • [26] Sensorimotor Incongruence in People with Musculoskeletal Pain: A Systematic Review
    Don, Sanneke
    Voogt, Lennard
    Meeus, Mira
    De Kooning, Margot
    Nijs, Jo
    PAIN PRACTICE, 2017, 17 (01) : 115 - 128
  • [27] Intratester and Intertester Reliability of Clinical Tests for the Assessment of Movement Control in Patients with Neck Pain
    Allofs, Jana
    van Baal, Katharina
    Schwarz, Fiona
    Ehrenbrusthoff, Katja
    Hering, Thomas
    PHYSIOSCIENCE, 2018, 14 (01) : 22 - 33
  • [28] Measurement Error of a Simplified Protocol for Quantitative Sensory Tests in Chronic Pain Patients
    Mueller, Monika
    Manresa, Jose Alberto Biurrun
    Limacher, Andreas
    Streitberger, Konrad
    Juni, Peter
    Andersen, Ole Koeseler
    Curatolo, Michele
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2017, 42 (05) : 660 - 668
  • [29] Neck muscle vibration can improve sensorimotor function in patients with neck pain
    Beinert, Konstantin
    Keller, Martin
    Taube, Wolfgang
    SPINE JOURNAL, 2015, 15 (03): : 514 - 521
  • [30] A systematic review of motor control tests in low back pain based on reliability and validity
    Schulz, Jane
    Vitt, Esther
    Niemier, Kay
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2022, 29 : 239 - 250