Clinical Utility of D-Dimer for Rule-Out or Rule-In of Venous Thromboembolism in Syncope

被引:1
|
作者
Badertscher, Patrick [1 ,2 ,3 ]
de Lavallaz, Jeanne du Fay [1 ,2 ,3 ]
Hammerer-Lercher, Angelika [4 ]
Mueller, Christian [1 ,2 ,3 ]
机构
[1] Univ Basel, Univ Hosp Basel, Cardiovasc Res Inst Basel CRIB, Petersgraben 4, CH-4031 Basel, Switzerland
[2] Univ Basel, Univ Hosp Basel, Dept Cardiol, Petersgraben 4, CH-4031 Basel, Switzerland
[3] GREAT Network, Basel, Switzerland
[4] Kantonsspital Aarau, Dept Lab Med, Aarau, Switzerland
基金
瑞士国家科学基金会;
关键词
Syncope; Pulmonary embolism; Diagnostic testing; PULMONARY-EMBOLISM; PREVALENCE;
D O I
10.1007/s12265-022-10306-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Graphical abstract: Fig. 1 Diagnostic performance of D-dimer using two different assays in patients presenting with syncope. A Left: Receiver-operating characteristic curves quantifying the diagnostic performance of Innovance® D-dimer (blue) and hs-Loci-Innovance® D-dimer (red) for the diagnosis of venous thromboembolism (VTE). Right: Clinical application of D-dimer using the 2-level Wells-score with age-adjusted1 or fixed cutoffs versus the YEARS-algorithm with probability-adjusted cut offs2. B Left: Specificity for different cufoffs of Innovance® D-dimer (blue) and hs-Loci-Innovance® D-dimer (red) for the diagnosis of venous thromboembolism (VTE). Right: Percentage of patients ruled-in and correctly identified VTE patients for different cutoffs of Innovance® D-dimer (blue) and hs-Loci-Innovance® D-dimer (red). 1In patients 50 years or younger, D-dimer concentration < 0.5 mg/l was considered negative. For patients older than 50 years, we used the formula: age in years divided by 100. 2YEARS-algorithm: assessment of only three items from the Wells-score (clinical signs of deep vein thrombosis, hemoptysis, pulmonary embolism the most likely diagnosis) and using a D-dimer test threshold of 0.5 mg/l in presence, and 1.0 mg/l in absence of one of the YEARS-items[Figure not available: see fulltext.]. © 2022, The Author(s).
引用
收藏
页码:427 / 429
页数:3
相关论文
共 50 条
  • [21] DOES A NORMAL D-DIMER RULE OUT CEREBRAL VENOUS SINUS THROMBOSIS (CVST)?
    Smith, Emma
    Kumar, Varun
    EMERGENCY MEDICINE JOURNAL, 2018, 35 (06) : 396 - +
  • [22] Early rule-out and rule-in of myocardial infarction using sensitive cardiac Troponin I
    Druey, Sophie
    Wildi, Karin
    Twerenbold, Raphael
    Jaeger, Cedric
    Reichlin, Tobias
    Haaf, Philip
    Gimenez, Maria Rubini
    Puelacher, Christian
    Wagener, Max
    Radosavac, Milos
    Honegger, Ursina
    Schumacher, Carmela
    Delfine, Valentina
    Kreutzinger, Philip
    Herrmann, Thomas
    Weidmann, Zoraida Moreno
    Krivoshei, Lian
    Freese, Michael
    Stelzig, Claudia
    Isenschmid, Cyril
    Bassetti, Stefano
    Rentsch, Katharina
    Osswald, Stefan
    Mueller, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 195 : 163 - 170
  • [23] D-dimer in venous thromboembolism
    Bockenstedt, P
    NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (13): : 1203 - 1204
  • [24] D-dimer and clinical probability to rule out pulmonary embolism in cancer patients: an explorative study to increase the clinical utility
    van Sluis, G. L.
    Douma, R. A.
    Sohne, M.
    Kamphuisen, P. W.
    Leebeek, F. W. G.
    Buller, H. R.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 117 - 118
  • [25] Clinical use of D-dimer testing in venous thromboembolism
    Levesque, H.
    Benhamou, Y.
    REVUE DE MEDECINE INTERNE, 2016, 37 (05): : 303 - 306
  • [26] The age-adjusted D-dimer cutoff level to rule out pulmonary embolism in patients with syncope
    Fuchs, Eyal
    Hardak, Emilia
    Keren-Politansky, Anat
    Hoffman, Ron
    Tzoran, Inna
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2022, 97 : 125 - 127
  • [27] CT Rule-in and Rule-out Criteria for Clinically Significant Portal Hypertension in Chronic Liver Disease
    Heo, Subin
    Lee, Seung Soo
    Choi, Sang Hyun
    Kim, Dong Wook
    Park, Hyo Jung
    Kim, So Yeon
    Lee, So Jung
    Kim, Kang Mo
    Shin, Yong Moon
    RADIOLOGY, 2023, 309 (01)
  • [28] An algorithm for rule-in and rule-out of acute myocardial infarction using a novel troponin I assay
    Lindahl, Bertil
    Jernberg, Tomas
    Badertscher, Patrick
    Boeddinghaus, Jasper
    Eggers, Kai M.
    Frick, Mats
    Rubini Gimenez, Maria
    Linder, Rickard
    Ljung, Lina
    Martinsson, Arne
    Melki, Dina
    Nestelberger, Thomas
    Rentsch, Katharina
    Reichlin, Tobias
    Sabti, Zaid
    Schubera, Marie
    Svensson, Per
    Twerenbold, Raphael
    Wildi, Karin
    Mueller, Christian
    HEART, 2017, 103 (02) : 125 - 131
  • [29] A single centre prospective cohort study addressing the effect of a rule-in/rule-out troponin algorithm on routine clinical practice
    Marjot, Jack
    Kaier, Thomas E.
    Henderson, Katherine
    Hunter, Laura
    Marber, Michael S.
    Perera, Divaka
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2019, 8 (05) : 404 - 411
  • [30] D-dimer to Rule Out Pulmonary Embolism in Renal Insufficiency
    Lindner, Gregor
    Funk, Georg-Christian
    Pfortmueller, Carmen A.
    Leichtle, Alexander B.
    Fiedler, Georg M.
    Schwarz, Christoph
    Exadaktylos, Aristomenis K.
    Puig, Stefan
    AMERICAN JOURNAL OF MEDICINE, 2014, 127 (04): : 343 - 347