Pubococcygeal Line Versus H-line as MR Defecography Reference for Bladder Descent

被引:0
|
作者
Chill, Henry H. [1 ]
Martin, Liam C. [2 ]
Chang, Cecilia [3 ]
Abramowitch, Steven D. [2 ]
Rostaminia, Ghazaleh [1 ]
机构
[1] Univ Chicago, Northshore Univ Hlth Syst, Div Urogynecol, Female Pelv Med & Reconstruct Surg FPMRS, 9650 Gross Point Rd,Suite 3900, Skokie, IL 60076 USA
[2] Univ Pittsburgh, Swanson Sch Engn, Dept Bioengn, Translat Biomech Lab, Pittsburgh, PA USA
[3] NorthShore Univ HealthSyst, Res Inst, Evanston, IL USA
关键词
Magnetic resonance imaging; Endovaginal ultrasound; Pelvic organ prolapse; Cystocele; H-line; Pubococcygeal line; Dynamic MRI of the pelvis; PELVIC ORGAN PROLAPSE;
D O I
10.1007/s00192-023-05707-x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction and hypothesis Magnetic resonance defecography imaging techniques have been used widely to study pelvic floor function and diagnose pelvic organ prolapse (POP). The aim of this study was to investigate the diagnostic accuracy of the H-line to detect bladder descent compared with the current landmark, the pubococcygeal line (PCL).Methods In this retrospective cohort study, patients who underwent MR defecography in our medical center and were diagnosed with moderate to severe cystocele by radiological measurements were recruited. One rest image and one maximum evacuation image for each subject were used for the following measurements: bladder base perpendicular distance from the genital hiatus (GH), indicative of clinically significant bladder descent, PCL as the current radiological reference line, and the H-line, or minimal levator hiatus line, indicative of pelvic floor muscle and connective tissue support. Subjects were categorized as having clinically significant cystocele if the "bladder base" reached within 1 cm or lower of the GH (stage II or higher cystocele). A comparison was performed to assess differences and predictive capabilities of the reference lines relative to the GH measure.Results Seventy subjects were included, 30 with clinically significant bladder descent based on distance to GH. Women with bladder descent were older (64.0 +/- 11.8 vs 51.2 +/- 15.6, p < 0.001), had increased parity (3 [1-7] vs 2 [0-5], p = 0.009), and had a bladder that descended lower than the H-line at rest (1.9 +/- 0.5 vs 2.2 +/- 0.4, p = 0.003) and evacuation (-2.4 +/- 1.6 vs -0.7 +/- 1.1, p < 0.001). Multivariate regression analysis confirmed that age, length of the H-line at evacuation, the perpendicular distances between the H-line and the lowest bladder point at rest, and the PCL to the lowest bladder point at evacuation significantly correlated with bladder descent. Receiver operating characteristic analysis was used to identify a measurement threshold to diagnose clinically significant cystocele for both measurements, bladder base to the H-line: -1.2 (80.0, 72.5) area under the curve (AUC) 0.82, and bladder base PCL: -3.3 (77.8, 79.5) AUC 0.86.Conclusion Our data support the application of using the minimal levator hiatus plane and specifically the H-line as a reliable landmark to diagnose bladder descent using MR defecography imaging.
引用
收藏
页码:537 / 544
页数:8
相关论文
共 50 条
  • [21] Analysis and Improvement of Repeated Wake-up Jittering H-line
    Wang, Qiang
    Zhang, Zhengxin
    Wang, Ye
    Jin, Honggui
    Sun, Qi
    Song, Yong
    Yu, Hongjun
    Xue, Hailin
    Che, Chuncheng
    2021 IEEE INTERNATIONAL SYMPOSIUM ON THE PHYSICAL AND FAILURE ANALYSIS OF INTEGRATED CIRCUITS (IPFA), 2021,
  • [22] MG-II H-LINE AND K-LINE OBSERVATIONS OF DELTA-SCUTI VARIABLES
    FRACASSINI, M
    PASINETTI, LE
    ASTRONOMY & ASTROPHYSICS, 1982, 107 (02) : 326 - 332
  • [23] SPECTRA OF PLAGES ON THE SUN AND STARS .1. CA-II H-LINE AND K-LINE
    LABONTE, BJ
    ASTROPHYSICAL JOURNAL SUPPLEMENT SERIES, 1986, 62 (01): : 229 - 239
  • [24] Supercritical metalens at h-line for high-resolution direct laser writing
    Jichao Fu
    Mengting Jiang
    Zeng Wang
    Yi Fan Chen
    Yuanda Liu
    Qing Yang Steve Wu
    Ai Jia Sim
    Jiang Wang
    Mingxi Chen
    Ziyu Wang
    Jie Deng
    Xiao Song Eric Tang
    Kun Huang
    Hong Liu
    Jinghua Teng
    Opto-Electronic Science, 2024, 3 (10) : 18 - 27
  • [25] THE LAMBDA-3969.26 FE-I LINE IN THE WING OF THE H-LINE OF CA-II IN THE QUIET SOLAR ATMOSPHERE
    BAYAZITOV, US
    SAKHIBULLIN, NA
    SOVIET ASTRONOMY LETTERS, 1990, 16 (03): : 240 - 243
  • [26] HIGH SPATIAL AND TEMPORAL RESOLUTION OBSERVATIONS OF THE SOLAR CA-II H-LINE
    CRAM, LE
    DAME, L
    ASTROPHYSICAL JOURNAL, 1983, 272 (01): : 355 - +
  • [27] SU-8 GPON Diplexer Based On H-Line Lithography by Direct Laser Writer
    Ramirez, Jhonattan C.
    Finardi, Celio A.
    Panepucci, Roberto R.
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2018, 30 (02) : 205 - 208
  • [28] Observational searches for chromospheric G-mode oscillations from CaII H-line observations
    R. Kariyappa
    L. Damé
    K. M. Hiremath
    Journal of Astrophysics and Astronomy, 2006, 27 : 327 - 331
  • [29] J-PARC MUSE H-line optimization for the g-2 and MuHFS experiments
    Toyoda, A.
    Fujiwara, Y.
    Fukao, Y.
    Kamigaito, O.
    Kawamura, N.
    Matsuda, Y.
    Mibe, T.
    Ogitsu, T.
    Saito, N.
    Sasaki, K.
    Shimomura, K.
    Sugano, M.
    Tanaka, K.
    Tomono, D.
    Torii, H. A.
    XIII INTERNATIONAL WORKSHOP ON NEUTRINO FACTORIES, SUPER BEAMS AND BETA BEAMS (NUFACT11), 2013, 408
  • [30] Observational searches for chromospheric g-mode oscillations from call H-line observations
    Kariyappa, R.
    Dame, L.
    Hiremath, K. M.
    JOURNAL OF ASTROPHYSICS AND ASTRONOMY, 2006, 27 (2-3) : 327 - 331