Ionophore-Based Polymeric Sensors for Potentiometric Assay of the Anticancer Drug Gemcitabine in Pharmaceutical Formulation: A Comparative Study

被引:1
|
作者
Mostafa, Gamal A. E. [1 ]
El-Tohamy, Maha F. [2 ]
Ali, Essam A. [1 ]
Al-Salahi, Rashad [1 ]
Attwa, Mohamed W. [1 ]
Alrabiah, Haitham [1 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi Arabia
[2] King Saud Univ, Coll Sci, Dept Chem, Riyadh 11495, Saudi Arabia
来源
MOLECULES | 2023年 / 28卷 / 22期
关键词
gemcitabine; ionophore; host-guest; PVC sensors; potentiometry; quality control; IN-VITRO; COMPLEXES; PLASMA; CANCER; HPLC;
D O I
10.3390/molecules28227552
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Gemcitabine is a chemotherapeutic agent used to treat various malignancies, including breast and bladder cancer. In the current study, three innovative selective gemcitabine hydrochloride sensors are developed using 4-tert-butylcalix-[8]-arene (sensor 1), beta-cyclodextrin (sensor 2), and gamma-cyclodextrin (sensor 3) as ionophores. The three sensors were prepared by incorporating the ionophores with o-nitrophenyl octyl ether as plasticizer and potassium tetrakis(4-chlorophenyl) borate as ionic additive into a polyvinyl chloride polymer matrix. These sensors are considered environmentally friendly systems in the analytical research. The linear responses of gemcitabine hydrochloride were in the concentration range of 6.0 x 10-6 to 1.0 x 10-2 mol L-1 and 9.0 x 10-6 to 1.0 x 10-2 mol L-1 and 8.0 x 10-6 to 1.0 x 10-2 mol L-1 for sensors 1, 2, and 3, respectively. Over the pH range of 6-9, fast-Nernst slopes of 52 +/- 0.6, 56 +/- 0.3, and 55 +/- 0.8 mV/decade were found in the same order with correlation regressions of 0.998, 0.999, and 0.998, respectively. The lower limits of detection for the prepared sensors were 2.5 x 10-6, 2.2 x 10-6, and 2.7 x 10-6 mol L-1. The sensors showed high selectivity and sensitivity for gemcitabine. Validation of the sensors was carried out in accordance with the requirements established by the IUPAC, while being inexpensive and easy to use in drug formulation. A statistical analysis of the methods in comparison with the official method showed that there was no significant difference in accuracy or precision between them. It was shown that the new sensors could selectively and accurately find gemcitabine hydrochloride in bulk powder, pharmaceutical formulations, and quality control tests. The ionophore-based sensor shows several advantages over conventional PVC membrane sensor sensors regrading the lower limit of detection, and higher selectivity towards the target ion.
引用
收藏
页数:18
相关论文
共 37 条
  • [21] Comparative Study of Holmium (III) Selective Sensors Based on Thiacalixarene and Calixarene Derivatives as an Ionophore
    Singh, Sanjay
    Rani, Geeta
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (07): : 2229 - 2237
  • [22] Cyclodextrin potentiometric sensors based on selective recognition sites for procainamide: Comparative and theoretical study
    AlRabiah, Haitham
    Homoda, Atef
    Bakheit, Ahmed
    Mostafa, Gamal A. E.
    OPEN CHEMISTRY, 2019, 17 (01): : 1222 - 1234
  • [23] Comparative Study for the Assay of Plant Derived Chemicals in Pharmaceutical Formulation Using Methods Dependent on Factorized Spectra
    Fahmy, Nesma M.
    Michael, Adel M.
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (04) : 968 - 974
  • [24] Green Assay of Tolmetin Sodium Using Solid Contact Potentiometric Sensor Doped with Ionophore and Supported with Docking Study: Application to Human Plasma and Pharmaceutical Formulations
    Mahrous, Manal F.
    Mabrouk, Mokhtar M.
    Habib, Ahmed
    Draz, Mohammed E.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (03)
  • [25] Comparative Study of Poly(Vinyl Chloride) Based Polymeric Membrane Sensors for the Determination of Erbium (III)
    Singh, Arpit
    Singh, Sanjay
    Singh, Gyanendra
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (03): : 296 - 314
  • [26] Carbon Nano-Dots based potentiometric sensor for the assay of the antiviral agent; Valacyclovir: In-Depth DFT Calculations, application to the pharmaceutical formulation and greenness assessment
    Hakiem, Ahmed Faried Abdel
    Kamal, Ahmed Mohsen
    Aboraia, Ahmed Safwat
    Mahfouz, M.
    Mohammed, Ahmed A. K.
    Naguib, Ibrahim A.
    Draz, Mohammed E.
    MICROCHEMICAL JOURNAL, 2024, 206
  • [27] COMPARATIVE MUTAGENICITY STUDY ON DIBROMODULCITOL (DBD), AN ALKYLATING ANTICANCER DRUG AND ITS 3 METABOLITES AND CYCLOPHOSPHAMIDE BY THE SALMONELLA MICROSOME ASSAY
    TOTH, K
    SUGAR, J
    SOMFAI, Z
    HEGEDUS, L
    MUTATION RESEARCH, 1982, 97 (03): : 230 - 230
  • [28] Kitchen-based diet versus commercial polymeric formulation in acute pancreatitis: a pilot randomized comparative study
    Grover, Indu
    Gunjan, Deepak
    Singh, Namrata
    Gopi, Srikanth
    Sati, Hem Chandra
    Sachdev, Vikas
    Saraya, Anoop
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2024, 78 (04) : 328 - 334
  • [29] Kitchen-based diet versus commercial polymeric formulation in acute pancreatitis: a pilot randomized comparative study
    Indu Grover
    Deepak Gunjan
    Namrata Singh
    Srikanth Gopi
    Hem Chandra Sati
    Vikas Sachdev
    Anoop Saraya
    European Journal of Clinical Nutrition, 2024, 78 : 328 - 334
  • [30] COMPARATIVE-STUDY ON THE POTENTIOMETRIC RESPONSES BETWEEN A VALINOMYCIN-BASED BILAYER LIPID-MEMBRANE AND A SOLVENT POLYMERIC MEMBRANE
    MINAMI, H
    SATO, N
    SUGAWARA, M
    UMEZAWA, Y
    ANALYTICAL SCIENCES, 1991, 7 (06) : 853 - 862