A Rapid and Sensitive Stability-Indicating Eco-Friendly HPTLC Assay for Fluorescence Detection of Ergotamine

被引:0
|
作者
Shakeel, Faiyaz [1 ]
Alam, Prawez [2 ]
Alqarni, Mohammed H. [2 ]
Haq, Nazrul [1 ]
Bar, Fatma M. Abdel [2 ]
Iqbal, Muzaffar [3 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut, Riyadh 11451, Saudi Arabia
[2] Prince Sattam Bin Abdulaziz Univ, Coll Pharm, Dept Pharmacognosy, Al Kharj 11942, Saudi Arabia
[3] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi Arabia
来源
MOLECULES | 2023年 / 28卷 / 13期
关键词
AGREE; ergotamine; fluorescence detection; eco-friendly HPTLC; stability indicating; validation; LIQUID-CHROMATOGRAPHY; HPLC METHOD; CAFFEINE; ALKALOIDS; QUANTIFICATION; INJECTION; TARTRATE; TABLETS; SAMPLES; CHEMISTRY;
D O I
10.3390/molecules28135101
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Eco-friendly liquid chromatographic methods for measuring ergotamine (EGT) are scant in the published database. Accordingly, the goal of the current study was to develop a high-performance thin-layer chromatography (HPTLC) method for fluorescence detection of EGT in commercially available tablets. This approach was based on the application of ethyl alcohol-water (80:20 v/v) as the eco-friendly eluent mixture. The fluorescence detection of EGT was carried out at 322 nm. The greenness score of the present approach was evaluated by "Analytical GREENness (AGREE)" technology. The present approach for measuring EGT in the 25-1000 ng band(-1) range was linear. The present assay for fluorescence detection of EGT was validated successfully by ICH guidelines for various parameters. The method was found to be rapid, sensitive, eco-friendly, and stability-indicating. The computed AGREE index for the current strategy was 0.84, displaying outstanding greenness features. The present methodology successfully separated the EGT degradation products under forced-degradation circumstances, exhibiting its stability-indicating qualities and selectivity. An amount of 99.33% of EGT was found in commercial formulations, indicating the validity of the current method for pharmaceutical analysis of EGT in commercial products. The results showed that EGT in commercial products might be regularly measured by the existing method.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] An eco-friendly, simple, and sensitive fluorescence biosensor for the detection of choline and acetylcholine based on C-dots and the Fenton reaction
    Wei, Jianfei
    Ren, Jun
    Liu, Jing
    Meng, Xianwei
    Ren, Xiangling
    Chen, Zhenzhen
    Tang, Fangqiong
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 52 : 304 - 309
  • [42] An eco-friendly stability-indicating spectrofluorimetric method for the determination of two anticancer stereoisomer drugs in their pharmaceutical preparations following micellar enhancement: Application to kinetic degradation studies
    El-Kimary, Eman I.
    El-Yazbi, Amira F.
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 163 : 145 - 153
  • [43] A rapid and eco-friendly isothermal amplification microdevice for multiplex detection of foodborne pathogens
    Trinh, Thi Ngoc Diep
    Lee, Nae Yoon
    [J]. LAB ON A CHIP, 2018, 18 (16) : 2369 - 2377
  • [44] Eco-friendly synthesis of egg-white capped silver nanoparticles for rapid, selective, and sensitive detection of Hg(II)
    Antonio Tirado-Guizar
    Geonel Rodriguez-Gattorno
    Francisco Paraguay-Delgado
    Gerko Oskam
    Georgina E. Pina-Luis
    [J]. MRS Communications, 2017, 7 : 695 - 700
  • [45] Eco-friendly synthesis of egg-white capped silver nanoparticles for rapid, selective, and sensitive detection of Hg(II)
    Tirado-Guizar, Antonio
    Rodriguez-Gattorno, Geonel
    Paraguay-Delgado, Francisco
    Oskam, Gerko
    Pina-Luis, Georgina E.
    [J]. MRS COMMUNICATIONS, 2017, 7 (03) : 695 - 700
  • [46] An eco-friendly HPTLC method for assay of eszopiclone in pharmaceutical preparation: investigation of its water-induced degradation kinetics
    El-Yazbi, Amira F.
    Youssef, Rasha M.
    [J]. ANALYTICAL METHODS, 2015, 7 (18) : 7590 - 7595
  • [47] A stability-indicating HPLC assay with diode array detection for the determination of a benzylpenicillin prodrug in aqueous solutions
    Jain, Rohit
    Wu, Zimei
    Tucker, Ian G.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 841 - 846
  • [48] Stability-indicating HPTLC method for the simultaneous detection and quantification of alfuzosin hydrochloride, solifenacin succinate along with four of their official impurities
    Tantawy, Mahmoud A.
    Weshahy, Soheir A.
    Wadie, Mina
    Rezk, Mamdouh R.
    [J]. MICROCHEMICAL JOURNAL, 2020, 157
  • [49] Disposable and eco-friendly electrochemical immunosensor for rapid detection of SARS-CoV-2
    Rocha, Danielly S.
    Baldo, Thaisa A.
    Silva-Neto, Habdias A.
    Duarte-Junior, Gerson F.
    Bazilio, Gabriela S.
    Borges, Clayton L.
    Parente-Rocha, Juliana A.
    de Araujo, William R.
    de Siervo, Abner
    Paixa, Thiago L. R. C.
    Coltro, Wendell K. T.
    [J]. TALANTA, 2024, 268
  • [50] Development of a Rapid and Eco-Friendly UHPLC Analytical Method for the Detection of Histamine in Fish Products
    Cicero, Antonello
    Galluzzo, Francesco Giuseppe
    Cammilleri, Gaetano
    Pulvirenti, Andrea
    Giangrosso, Giuseppe
    Macaluso, Andrea
    Vella, Antonio
    Ferrantelli, Vincenzo
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (20) : 1 - 11